Comparison of MALDI-TOF-MS and HPLC-ESI-MS/MS for Endopeptidase Activity-Based Quantification of Anthrax Lethal Factor in Serum

被引:22
作者
Kuklenyik, Zsuzsanna [1 ]
Boyer, Anne E. [1 ]
Lins, Renato [1 ,3 ]
Quinn, Conrad P. [2 ]
Gallegos-Candela, Maribel [1 ]
Woolfitt, Adrian [1 ]
Pirkle, James L. [1 ]
Barr, John R. [1 ]
机构
[1] Ctr Dis Control & Prevent, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
[2] Ctr Dis Control & Prevent, Natl Ctr Immunizat & Resp Dis, Atlanta, GA 30333 USA
[3] Battelle Atlanta Analyt Serv, Atlanta, GA 30329 USA
关键词
MASS-SPECTROMETRY; INHALATION ANTHRAX;
D O I
10.1021/ac1030144
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Diagnosing and treating anthrax at the earliest stage of disease is critical. We developed a method to diagnose anthrax at early stages of infection by detecting anthrax lethal factor (LF) at the attomol/mL level in plasma or serum. This method uses antibody capture and quantification of LF endoproteinase activity by isotope dilution matrix-assisted laser-desorption ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS). Many public health laboratories do not use MALDI-TOF-MS; thus, we have adapted the LF method for detection by electrospray ionization (ESI) tandem MS (MS/MS), which allowed comparison of both MS platforms for LF quantification. Calibration curves were linear from 0.05-2.5 ng/mL when measured after 2 h and from 0.005-1.0 ng/mL after 18 h incubation time. The limit of detection was 0.005 ng/mL using a 200 mu L sample. The coefficient of variation for quality control samples was 6-12% for both MS platforms. Samples used to perform cross-validation included 158 serum samples from a study in rabbits exposed to anthrax spores by inhalation. Some were treated with anthrax immune globulin before exposure. Concentrations measured by ESI-MS/MS matched those by MALDI-TOF-MS with p = 0.99 (r(2) = 0.997) and -0.25% mean relative difference (+/-9% standard deviation). This study shows that isotope dilution MALDI-TOF-MS is a robust and precise quantitative MS platform.
引用
收藏
页码:1760 / 1765
页数:6
相关论文
共 11 条
[1]   Biological monitoring of exposure to botulinum neurotoxins [J].
Barr, John R. ;
Kalb, Suzanne R. ;
Moura, Hercules ;
Pirkle, James L. .
JOURNAL OF CHEMICAL HEALTH & SAFETY, 2008, 15 (06) :14-19
[2]   From the mouse to the mass spectrometer: Detection and differentiation of the endoproteinase activities of botulinum neurotoxins A-G by mass spectrometry [J].
Boyer, AE ;
Moura, H ;
Woolfitt, AR ;
Kalb, SR ;
McWilliams, LG ;
Pavlopoulos, A ;
Schmidt, JG ;
Ashley, DL ;
Barr, JR .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :3916-3924
[3]  
BOYER AE, 2009, INT BACILLUS ANTHR S, V5, P5
[4]   Detection and quantification of anthrax lethal factor in serum by mass spectrometry [J].
Boyer, Anne E. ;
Quinn, Conrad P. ;
Woolfitt, Adrian R. ;
Pirkle, James L. ;
McWilliams, Lisa G. ;
Stamey, Karen L. ;
Bagarozzi, Dennis A. ;
Hart, John C., Jr. ;
Barr, John R. .
ANALYTICAL CHEMISTRY, 2007, 79 (22) :8463-8470
[5]   Kinetics of Lethal Factor and Poly-D-Glutamic Acid Antigenemia during Inhalation Anthrax in Rhesus Macaques [J].
Boyer, Anne E. ;
Quinn, Conrad P. ;
Hoffmaster, Alex R. ;
Kozel, Thomas R. ;
Saile, Elke ;
Marston, Chung K. ;
Percival, Ann ;
Plikaytis, Brian D. ;
Woolfitt, Adrian R. ;
Gallegos, Maribel ;
Sabourin, Patrick ;
McWilliams, Lisa G. ;
Pirkle, James L. ;
Barr, John R. .
INFECTION AND IMMUNITY, 2009, 77 (08) :3432-3441
[6]  
CHAPLIN M, 1990, ENZYME TECHNOLOGY, pCH3
[7]   Arrayed time-of-flight mass spectrometry for time-critical detection of hazardous agents [J].
Cornish, TJ ;
Antoine, MD ;
Ecelberger, SA ;
Demirev, PA .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :3954-3959
[8]  
Demirev PA, 2005, J HOPKINS APL TECH D, V26, P321
[9]   Mass Spectrometry for Rapid Characterization of Microorganisms [J].
Demirev, Plamen A. ;
Fenselau, Catherine .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2008, 1 (01) :71-93
[10]  
Duncan Mark W., 2008, Briefings in Functional Genomics & Proteomics, V7, P355, DOI 10.1093/bfgp/eln041