Comparison of All- and Alternate-Poles-Wound Flux-Switching PM Machines Having Different Stator and Rotor Pole Numbers

被引:128
作者
Chen, J. T. [1 ]
Zhu, Z. Q. [1 ]
机构
[1] Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
关键词
Brushless; fault tolerant; flux switching; permanent magnet (PM); unbalanced magnetic force (UMF); PERMANENT-MAGNET; PROXIMITY LOSS; PERFORMANCE; MOTORS;
D O I
10.1109/TIA.2010.2049812
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The influence of stator and rotor pole numbers, viz. 6/5, 6/7, 12/10, 12/11, 12/13, and 12/14 stator/rotor poles, etc., on the electromagnetic performance of three-phase flux-switching permanent-magnet (FSPM) machines with all and alternate poles wound is investigated in this paper. It shows that the back-EMF waveform, winding inductance, unbalanced magnetic force, and torque density in an FSPM machine are all significantly affected by the stator and rotor pole numbers and winding configurations, as confirmed by both finite-element analyses and measurements.
引用
收藏
页码:1406 / 1415
页数:10
相关论文
共 23 条
[1]  
Chen J. T., 2010, IEEE T IND APPL, V46
[2]  
CHEN JT, IEEE T ENER IN PRESS
[3]   Synthesis of high performance PM motors with concentrated windings [J].
Cros, M ;
Viarouge, P .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2002, 17 (02) :248-253
[4]  
Hoang E, 2000, IEEE IND APPLIC SOC, P299, DOI 10.1109/IAS.2000.881127
[5]  
Hoang E., 1997, P 7 EUR C POW EL APP, V3, P903
[6]   Comparison of electromagnetic performance of brushless motors having magnets in stator and rotor [J].
Hua, Wei ;
Cheng, Ming ;
Zhu, Z. Q. ;
Zhao, Wenxiang ;
Kong, Xiangxin .
JOURNAL OF APPLIED PHYSICS, 2008, 103 (07)
[7]   Comparison of PM brushless motors, having either all teeth or alternate teeth wound [J].
Ishak, D ;
Zhu, ZQ ;
Howe, D .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (01) :95-103
[8]   Influence of PWM on the Proximity Loss in Permanent-Magnet Brushless AC Machines [J].
Iwasaki, S. ;
Deodhar, Rajesh P. ;
Liu, Yong ;
Pride, Adam ;
Zhu, Z. Q. ;
Bremner, Jonathan James .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (04) :1359-1367
[9]   A comparative study of permanent magnet and switched reluctance motors for high-performance fault-tolerant applications [J].
Jack, AG ;
Mecrow, BC ;
Haylock, JA .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (04) :889-895
[10]   Inducible nitric oxide synthase, Nos2, does not mediate optic neuropathy and retinopathy in the DBA/2J glaucoma model [J].
Libby, Richard T. ;
Howell, Gareth R. ;
Pang, Iok-Hou ;
Savinova, Olga V. ;
Mehalow, Adrienne K. ;
Barter, Joseph W. ;
Smith, Richard S. ;
Clark, Abbot F. ;
John, Simon W. M. .
BMC NEUROSCIENCE, 2007, 8 (1)