Broadband Transmission via Underground Medium-Voltage Power Lines - Part II: Capacity

被引:23
作者
Lazaropoulos, Athanasios G. [1 ]
Cottis, Panayiotis G. [1 ]
机构
[1] Natl Tech Univ Athens, Sch Elect & Comp Engn, Athens, Greece
关键词
Broadband over power lines (BPL); channel capacity; interoperability and intraoperability; modal analysis; power-line communications (PLC); underground medum-voltage (MV) power lines; COMMUNICATION; CHANNEL; MODEL; NETWORKS; NOISE;
D O I
10.1109/TPWRD.2010.2052113
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The end-to-end transfer function of three-phase underground medium-voltage broadband over power-lines (MV/BPL) cables with common shield and armor is determined based on a new exact version of the chain scattering matrix method. The various topologies of the underground MV grid are studied with regard to the spectral behavior of the end-to-end attenuation and to the respective capacity and are compared to the corresponding overhead cases. The numerical results reveal that broadband transmission via underground MV power lines depends drastically on the type of cables used and the topology of the underground MV grid. Also, the relaxed power injection limits and the lower noise power levels characterizing underground MV/BPL transmission counteract the extremely high inherent attenuation, making the capacity achieved compatible to that achieved in overhead MV/BPL transmission.
引用
收藏
页码:2425 / 2434
页数:10
相关论文
共 36 条
[31]   Control and operation of power sources in a medium-voltage direct-current microgrid for an electric vehicle fast charging station with a photovoltaic and a battery energy storage system [J].
Garcia-Trivino, Pablo ;
Torreglosa, Juan P. ;
Fernandez-Ramirez, Luis M. ;
Jurado, Francisco .
ENERGY, 2016, 115 :38-48
[32]   Semi-active control of forced oscillations in power transmission lines via optimum tuneable vibration absorbers: With review on linear dynamic aspects [J].
Saadabad, Navid Asmari ;
Moradi, Harried ;
Vossoughi, Gholamreza .
INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2014, 87 :163-178
[33]   Heterogeneous public preferences for undergrounding high-voltage power transmission lines: The case of Seoul metropolitan area in South Korea [J].
Choi, Hyunhong ;
Shim, Dongnyok ;
Kim, Seung Wan .
ENERGY ECONOMICS, 2024, 132
[34]   Optimum design of tuned mass damper via PSO algorithm for the passive control of forced oscillations in power transmission lines [J].
Abbasi, Mohammad Hossein ;
Moradi, Hamed .
SN APPLIED SCIENCES, 2020, 2 (05)
[35]   COMBINED NUMERICAL FINITE ELEMENT AND EXPERIMENTAL OPTIMIZATION APPROACH IN THE PRODUCTION PROCESS OF MEDIUM-VOLTAGE, RUBBER-INSULATED ELECTRIC CABLES VULCANIZED WITH STEAM WATER. PART 2: NUMERICAL SIMULATIONS AND INVERSE ANALYSES [J].
Milani, G. ;
Milani, F. .
RUBBER CHEMISTRY AND TECHNOLOGY, 2015, 88 (04) :527-546
[36]   COMBINED NUMERICAL, FINITE ELEMENT AND EXPERIMENTAL-OPTIMIZATION APPROACH IN THE PRODUCTION PROCESS OF MEDIUM-VOLTAGE, RUBBER-INSULATED ELECTRIC CABLES VULCANIZED WITH STEAM WATER. PART 1: DSC AND RHEOMETER EXPERIMENTAL RESULTS [J].
Milani, G. ;
Galanti, A. ;
Cardelli, C. ;
Milani, F. ;
Cardelli, A. .
RUBBER CHEMISTRY AND TECHNOLOGY, 2015, 88 (03) :482-501