Local heat transfer distribution in a square channel with 90° continuous, 90° saw tooth profiled and 60° broken ribs

被引:49
作者
Gupta, Abhishek [1 ]
SriHarsha, V. [1 ]
Prabhu, S. V. [1 ]
Vedula, R. P. [1 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Bombay 400076, Maharashtra, India
关键词
heat transfer enhancement; 90 degrees continuous ribs; 90 degrees profiled ribs; V-broken ribs; thin metal foil technique;
D O I
10.1016/j.expthermflusci.2007.11.015
中图分类号
O414.1 [热力学];
学科分类号
摘要
Internal channel cooling is employed in advanced gas turbines blade to allow high inlet temperatures so as to achieve high thrust/weight ratios and low specific fuel consumption. The objective of the present study is to measure the local heat transfer distributions in a double wall ribbed square channel with 90 degrees continuous, 90 degrees saw tooth profiled and 60 degrees V-broken ribs. Comparison is made between the 90 degrees continuous ribs (Ple = 7 and 10 for a elD = 0.15) and 90 degrees saw tooth profiled rib configurations (Ple = 7 for an elD = 0.15) for the same rib height to the hydraulic diameter ratio (elD). The effect of pitch to rib height ratio (Ple = 7.5,10 and 12) of 60 degrees V-broken ribbed channel with a constant rib height to hydraulic diameter ratio (elD) of 0.0625 on the local heat transfer distribution is studied. The Reynolds number based on duct hydraulic diameter is ranging from 10,000 to 30,000. A thin stainless steel foil of 0.05 mm thickness is used as heater and infrared thermography technique is used to obtain the local temperature distribution on the surface. The images are captured in the periodically fully developed region of the channel. It is observed that the heat transfer augmentations in the channel with 90 degrees saw tooth profiled ribs are comparable with those of 90 degrees continuous ribs. The enhancements caused by 60 degrees V-broken ribs are higher than those of 90 degrees continuous ribs. The effect of pitch to the rib height ratio (Ple) is not significant for channel with 60 degrees V-broken ribs for a given rib height to hydraulic diameter ratio (elD = 0.0625). (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:997 / 1010
页数:14
相关论文
共 11 条
[1]   Heat transfer enhancements in rotating two-pass coolant channels with profiled ribs: Part 1 - Average results [J].
Acharya, S ;
Eliades, V ;
Nikitopoulos, DE .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2001, 123 (01) :97-106
[2]   Heat transfer and friction behaviors in rectangular channels with varying number of ribbed walls [J].
Chandra, PR ;
Alexander, CR ;
Han, JC .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (03) :481-495
[3]   HIGH-PERFORMANCE HEAT-TRANSFER DUCTS WITH PARALLEL BROKEN AND V-SHAPED BROKEN RIBS [J].
HAN, JC ;
ZHANG, YM .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (02) :513-523
[4]   AUGMENTED HEAT-TRANSFER IN SQUARE CHANNELS WITH PARALLEL, CROSSED, AND V-SHAPED ANGLED RIBS [J].
HAN, JC ;
ZHANG, YM ;
LEE, CP .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1991, 113 (03) :590-596
[5]  
KLINE SJ, 1953, MECH ENG, V75
[6]  
LION TM, 2000, J HEAT TRANSFER, V122, P327
[7]   Heat transfer enhancements in rotating two-pass coolant channels with profiled ribs: Part 2 - Detailed measurements [J].
Nikitopoulos, DE ;
Eliades, V ;
Acharya, S .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2001, 123 (01) :107-114
[8]   The effect of periodic ribs on the local aerodynamic and heat transfer performance of a straight cooling channel [J].
Rau, G ;
Cakan, M ;
Moeller, D ;
Arts, T .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1998, 120 (02) :368-375
[9]   Experimental validation of large eddy simulations of flow and heat transfer in a stationary ribbed duct [J].
Sewall, EA ;
Tafti, DK ;
Graham, AB ;
Thole, KA .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2006, 27 (02) :243-258
[10]   Heat transfer in rectangular channels with transverse and V-shaped broken ribs [J].
Tanda, G .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (02) :229-243