Determination of albendazole metabolites by direct injection of bovine plasma and multidimensional achiral-chiral high performance liquid chromatography

被引:28
作者
Belaz, Katia Roberta A. [1 ]
Cass, Quezia B. [1 ]
Oliveira, Regina V. [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, BR-13565905 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
restricted access media (RAM); direct injection; antihelmintics; bovine plasma; albendazole metabolites; polysaccharide chiral phases;
D O I
10.1016/j.talanta.2008.02.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development and validation of a fully automated achiral-chiral high performance liquid chromatography (HPLC) method for the simultaneous determination of albendazole metabolites: enantiomers of albendazole sulphoxide (ABZ-SO), albenclazole sulphone (ABZ-SO2) and albendazole 2-aminosulphone (ABZ-SO2NH2) in bovine plasma are described. This method involves an octyl restricted access media bovine serum albumin column (C-8-RAM-BSA) (50 mm x 4.6 mm I.D.) for sample clean-up, followed by enantioselective analysis on a column containing an amylose tris(3,5-dimethylphenylcarbamate) stationary phase (150 mm x 4.6 mm I.D.). The chromatographic separations of all target compounds were performed at 30 degrees C using a mobile phase composed of phosphate buffer (10 mmol L-1; pH 7.5):acetonitrile (60:40, v/v), flow rate of 0.5 mL min(-1) and fluorescence detection at 290 nm and 320 nm, excitation and emission, respectively. The influence of different organic modifiers and chiral selector of the stationary phase on enantioseparation of ABZ-SO was investigated. The method developed was fully validated. The calibration curves were linear in the concentration range of 40.00-1280 ng mL(-1) for each albendazole sulphoxide enantiomer, 10.0-320 ng mL(-1) for albendazole sulphone and 20.0-320 ng mL(-1) for albendazole 2-aminosulphone. The inter- and intra-day precision ranged from 0.760% to 7.79% relative standard deviation (R.S.D.), and the accuracy ranged 101% from 114% of the nominal values while the transfer efficiency was in the range of 84.4-103%. The method showed good linearity, precision, accuracy, sensitivity and selectivity allowing it to be appropriate for further pharmacokinetics and metabolism studies of albendazole. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:146 / 153
页数:8
相关论文
共 57 条
[1]  
Ali MH, 1998, SYNTHESIS-STUTTGART, P1238
[2]  
AMRI HS, 1988, J PHARMACOL EXP THER, V246, P758
[3]  
ANDERSON DJ, 1993, ANAL CHEM, V65, pR434
[4]   Selective and mild oxidation of sulfides to sulfoxides by oxodiperoxo molybdenum complexes adsorbed onto silica gel [J].
Batigalhia, F ;
Zaldini-Hernandes, M ;
Ferreira, AG ;
Malvestiti, I ;
Cass, QB .
TETRAHEDRON, 2001, 57 (48) :9669-9676
[5]   Quantitative determination of albendazole metabolites in sheep spermatozoa and seminal plasma by liquid chromatographic analysis with fluorescence detection [J].
Batzias, GC ;
Theodosiadou, E ;
Delis, GA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (05) :1191-1202
[6]   Ex vivo anthelmintic activity of albendazole-sulphoxide enantiomers [J].
Bolás-Fernández, F ;
Rama-Iñiguez, S ;
Torrado, JJ .
JOURNAL OF PARASITOLOGY, 2004, 90 (02) :407-409
[7]  
Boos KS, 1997, LC GC-MAG SEP SCI, V15, P602
[8]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[9]   Pharmacokinetic behaviour of albendazole sulphoxide enantiomers in male and female sheep [J].
Capece, BPS ;
Castells, G ;
Pérez, F ;
Arboix, M ;
Cristòfol, C .
VETERINARY RESEARCH COMMUNICATIONS, 2000, 24 (05) :339-348
[10]   Enantiomeric determination of the plasma levels of omeprazole by direct plasma injection using high-performance liquid chromatography with achiral-chiral column-switching [J].
Cass, QB ;
Lima, VV ;
Oliveira, RV ;
Cassiano, NM ;
Degani, ALG ;
Pedrazzoli, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 798 (02) :275-281