Experimental and numerical investigation on the performance of an internally cooled dehumidifier

被引:14
|
作者
Turgut, Oguz Emrah [1 ]
Coban, Mustafa Turhan [1 ]
机构
[1] Ege Univ, Dept Mech Engn, TR-35040 Izmir, Turkey
关键词
COOLED/HEATED DEHUMIDIFIER/REGENERATOR; MASS-TRANSFER; DESICCANT; ENERGY; MODEL;
D O I
10.1007/s00231-016-1782-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
Liquid desiccant based dehumidifiers are important components of the air conditioning applications. Internally cooled dehumidifiers with liquid desiccants are deemed to be superior to the adiabatic types, thanks to the cooling medium which takes away the latent heat of vaporization occured when moist air contacts with liquid desiccant. However, its utilization in industrial applications is restricted due to the inherent corrosive characteristics of the liquid desiccants. In this study, an experimental chamber is built for epoxy coated plate fin type dehumidifier which is used in order to diminish the corrosive effect of the lithium chloride aqueous solution. Dehumidification effectiveness and moisture removal rate, two parameter indices, are adopted to measure the performance of the air conditioning system. The effect of inlet operating parameters on moisture removal rates is extensively analyzed. Two dimensional numerical model adapted from the conservation principles is utilized for obtainment of output parameters. Experimental results are compared with the numerical model and comparisons show that numerical outputs agrees with the experimental results. And also, dehumidification performance of lithium chloride and lithium bromide aqueous solutions are evaluated and compared against each other.
引用
收藏
页码:2707 / 2722
页数:16
相关论文
共 50 条
  • [1] Experimental and numerical investigation on the performance of an internally cooled dehumidifier
    Oguz Emrah Turgut
    Mustafa Turhan Çoban
    Heat and Mass Transfer, 2016, 52 : 2707 - 2722
  • [2] Numerical simulation for the performance of internally cooled dehumidifier
    Zhao, Y
    Shi, MH
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 980 - 983
  • [3] Performance numerical analysis on an internally-cooled liquid desiccant dehumidifier
    Chan, X. M.
    Liu, X. H.
    Jiang, Y.
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 607 - 613
  • [4] Experimental analysis of an innovative internally cooled dehumidifier
    Du, Boyao
    Zhang, Guangkai
    Xie, Jingchao
    Liu, Honggang
    Liu, Jiaping
    JOURNAL OF BUILDING ENGINEERING, 2023, 80
  • [5] Investigation on Performance of Internally Cooled Liquid Desiccant Dehumidifier Based on ANN Model
    Luo, Yimo
    Chang, Yayin
    Li, Nianping
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2024, 51 (09): : 198 - 205
  • [6] Experimental analysis of an internally-cooled liquid desiccant dehumidifier
    Zhang, Tao
    Liu, Xiaohua
    Jiang, Jingjing
    Chang, Xiaoming
    Jiang, Yi
    BUILDING AND ENVIRONMENT, 2013, 63 : 1 - 10
  • [7] Experimental and Theoretical Study of an Internally Cooled Liquid Desiccant Dehumidifier
    ZHENG Xin
    LU Yuan
    WANG Bo
    ZHAO Lifeng
    XIAO Yunhan
    Journal of Thermal Science, 2023, 32 (04) : 1684 - 1696
  • [8] Experimental and Theoretical Study of an Internally Cooled Liquid Desiccant Dehumidifier
    Xin Zheng
    Yuan Lu
    Bo Wang
    Lifeng Zhao
    Yunhan Xiao
    Journal of Thermal Science, 2023, 32 : 1684 - 1696
  • [9] Experimental and Theoretical Study of an Internally Cooled Liquid Desiccant Dehumidifier
    Zheng, Xin
    Lu, Yuan
    Wang, Bo
    Zhao, Lifeng
    Xiao, Yunhan
    JOURNAL OF THERMAL SCIENCE, 2023, 32 (04) : 1684 - 1696
  • [10] Performance analysis on the internally cooled dehumidifier using liquid desiccant
    Liu, X. H.
    Chang, X. M.
    Xia, J. J.
    Jiang, Y.
    BUILDING AND ENVIRONMENT, 2009, 44 (02) : 299 - 308