Analysis of Dose Distribution and Risk of Pneumonitis in Stereotactic Body Radiation Therapy for Centrally Located Lung Tumors: A Comparison of Robotic Radiosurgery, Helical Tomotherapy and Volumetric Modulated Arc Therapy

被引:13
|
作者
Kannarunimit, Danita [1 ]
Descovich, Martina [2 ]
Garcia, Aaron [2 ]
Chen, Josephine [2 ]
Weinberg, Vivian [2 ]
Mcguinness, Christopher [2 ]
Pinnaduwage, Dilini [2 ]
Murnane, John [2 ]
Gottschalk, Alexander R. [2 ]
Yom, Sue S. [2 ]
机构
[1] King Chulalongkorn Univ Hosp, Dept Radiat Oncol, Bangkok, Thailand
[2] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
Central lung; SBRT; Robotic radiosurgery; Helical tomotherapy; VMAT; Pneumonitis; CYBERKNIFE RADIOSURGERY; TRACKING SYSTEM; MEGAVOLTAGE CT; RADIOTHERAPY; CANCER; RECONSTRUCTION; TOXICITY; ACCURACY; SBRT; VMAT;
D O I
10.7785/tcrt.2012.500394
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Stereotactic body radiation therapy (SBRT) to central lung tumors is associated with normal tissue toxicity. Highly conformal technologies may reduce the risk of complications. This study compares physical dose characteristics and anticipated risks of radiation pneumonitis (RP) among three SBRT modalities: robotic radiosurgery (RR), helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT). Nine patients with central lung tumors. 5 cm were compared. RR, HT and VMAT plans were developed per RTOG 0831. Dosimetric comparisons included target coverage, conformity index, heterogeneity index, gradient index, maximal dose at 2 cm from target (D2cm), and dose-volume parameters for organs at risk (OARs). Efficiency endpoints included total beam-on time and monitor units. RP risk was derived from Lyman-Kutcher-Burman modeling on in-house software. The average GTV and PTV were 11.6 +/- 7.86 cm(3) and 36.8 +/- 18.1 cm(3). All techniques resulted in similar target coverage (p = 0.64) and dose conformity (p = 0.88). While RR had sharper fall-off gradient (p = 0.002) and lower D2 cm (p = 0.02), HT and VMAT produced greater homogeneity (p < 0.001) and delivery efficiency (p = 0.001). RP risk predicted from whole or contralateral lung volumes was less than 10%, but was 2-3 times higher using ipsilateral volumes. Using whole (p = 0.04, p = 0.02) or ipsilateral (p = 0.004, p = 0.0008) volumes, RR and VMAT had a lower risk of RP than HT. Using contralateral volumes, RR had the lowest RP risk (p = 0.0002, p = 0.0003 versus HT, VMAT). RR, HT and VMAT were able to provide clinically acceptable plans following the guidelines provided by RTOG 0813. All techniques provided similar coverage and conformity. RR seemed to produce a lower RP risk for a scenario of small PTV-OAR overlap and small PTV. VMAT and HT produced greater homogeneity, potentially desirable for a large PTV-OAR overlap. VMAT probably yields the lowest RP risk for a large PTV. Understanding subtle differences among these technologies may assist in situations where multiple choices of modality are available.
引用
收藏
页码:49 / 60
页数:12
相关论文
共 50 条
  • [21] Volumetric modulated arc therapy for lung stereotactic radiation therapy can achieve high local control rates
    Yamashita, Hideomi
    Haga, Akihiro
    Takahashi, Wataru
    Takenaka, Ryousuke
    Imae, Toshikazu
    Takenaka, Shigeharu
    Nakagawa, Keiichi
    RADIATION ONCOLOGY, 2014, 9 : 243
  • [22] VOLUMETRIC-MODULATED ARC THERAPY FOR STEREOTACTIC BODY RADIOTHERAPY OF LUNG TUMORS: A COMPARISON WITH INTENSITY-MODULATED RADIOTHERAPY TECHNIQUES
    Holt, Andrea
    van Vliet-Vroegindeweij, Corine
    Mans, Anton
    Belderbos, Jose S.
    Damen, Eugene M. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05): : 1560 - 1567
  • [23] Dosimetric comparison of flattened and unflattened beams for stereotactic body radiation therapy: Impact of the size of the PTV on dynamic conformal arc and volumetric modulated arc therapy
    Vieillevigne, Laure
    Bessieres, Sandra
    Ouali, Monia
    Lanaspeze, Christel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (11): : 1405 - 1414
  • [24] Critical Structure Sparing in Stereotactic Ablative Radiotherapy for Central Lung Lesions: Helical Tomotherapy vs. Volumetric Modulated Arc Therapy
    Chi, Alexander
    Ma, Pan
    Fu, Guishan
    Hobbs, Gerry
    Welsh, James S.
    Nguyen, Nam P.
    Jang, Si Young
    Dai, Jinrong
    Jin, Jing
    Komaki, Ritsuko
    PLOS ONE, 2013, 8 (04):
  • [25] Minimizing dose variation from the interplay effect in stereotactic radiation therapy using volumetric modulated arc therapy for lung cancer
    Kubo, Kazuki
    Monzen, Hajime
    Tamura, Mikoto
    Hirata, Makoto
    Ishii, Kentaro
    Okada, Wataru
    Nakahara, Ryuta
    Kishimoto, Shun
    Kawamorita, Ryu
    Nishimura, Yasumasa
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 121 - 127
  • [26] Evaluation of collimator rotation for volumetric modulated arc therapy lung stereotactic body radiation therapy using flattening filter free
    Sandrini, Emmily Santos
    da Silva, Ademir Xavier
    da Silva, Claudia Menezes
    APPLIED RADIATION AND ISOTOPES, 2018, 141 : 257 - 260
  • [27] Radiation Pneumonitis After Volumetric Modulated Arc Therapy for Non-small Cell Lung Cancer
    Fujiwara, Masayuki
    Doi, Hiroshi
    Igeta, Masataka
    Suzuki, Hitomi
    Kitajima, Kazuhiro
    Tanooka, Masao
    Ishida, Toshihisa
    Wakayama, Tsukasa
    Yokoi, Takashi
    Kuribayashi, Kozo
    Kijima, Takashi
    Hashimoto, Masaki
    Kondo, Nobuyuki
    Matsumoto, Seiji
    Hasegawa, Seiki
    Kamikonya, Norihiko
    Yamakado, Koichiro
    ANTICANCER RESEARCH, 2021, 41 (11) : 5793 - 5802
  • [28] SmartArc-based volumetric modulated arc therapy for endometrial cancer: a dosimetric comparison with helical tomotherapy and intensity-modulated radiation therapy
    Ruijie Yang
    Junjie Wang
    Shouping Xu
    Hua Li
    BMC Cancer, 13
  • [29] SmartArc-based volumetric modulated arc therapy for endometrial cancer: a dosimetric comparison with helical tomotherapy and intensity-modulated radiation therapy
    Yang, Ruijie
    Wang, Junjie
    Xu, Shouping
    Li, Hua
    BMC CANCER, 2013, 13
  • [30] Dosimetric study for spine stereotactic body radiation therapy: magnetic resonance guided linear accelerator versus volumetric modulated arc therapy
    Yadav, Poonam
    Musunuru, Hima B.
    Witt, Jacob S.
    Bassetti, Michael
    Bayouth, John
    Baschnagel, Andrew M.
    RADIOLOGY AND ONCOLOGY, 2019, 53 (03) : 362 - 368