Stereotactic Radiotherapy for Choroidal Melanoma: Analysis of Eye Movement During Treatment, Eye Simulator Design and Automated Monitoring System Development

被引:1
作者
Souza, F. [1 ]
Valani, J. [2 ]
Goncalves, O. D. [2 ]
Batista, D. V. S. [3 ]
Cardoso, S. C. [2 ]
Pereira, D. D. [2 ]
机构
[1] Univ Fed Rio de Janeiro, Polytech Sch, BR-21941901 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Rio de Janeiro, Inst Phys, BR-21941909 Rio de Janeiro, RJ, Brazil
[3] Natl Commiss Nucl Energy, Inst Radioprotect & Dosimetry, BR-22780160 Rio De Janeiro, RJ, Brazil
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3 | 2019年 / 68卷 / 03期
关键词
Stereotactic radiotherapy; Choroidal melanoma Eye simulator; UVEAL MELANOMA;
D O I
10.1007/978-981-10-9023-3_89
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Malignant choroidal melanoma is a choroidal tumor arising in the layer of blood vessels located beneath the retina. It is a rare occurrence, affecting five to every million inhabitants and rapidly evolving into metastasis. The stereotactic radiotherapy is one of the possible treatments for the disease, it consists in the application of small photon beams directed to the PTV, the prescribed dose is delivered in multiple sessions. The success of treatment depends directly, among others biomedical factors, on the precision of the application and how the treatment method can hold still the patient's eye. This study aims: (a) to analyze the eye's movement during the treatment for choroidal melanoma and the non-invasive method for fixating the patient's eye; (b) to develop a monitoring software for patient eye gaze; (c) design a mechanical eye to verify the monitoring system. As a result, it is expected that the system will be improved, raising the precision and accuracy of application and reducing the damage to healthy tissues and side effects. After analyzing the positions of the iris center and calculating its displacements relative to the orthophoria point the standard deviation values of 0.368 mm and 0.364 mm were found for the X-axis and Y-axis, respectively. The LED lamp is enough for a noninvasive fixation of the patient's eye during treatment. The mechanical eye now is able to verify the monitoring system software, as both work with resolutions within the limit given by the eye movement analyzes.
引用
收藏
页码:493 / 497
页数:5
相关论文
共 13 条
[1]  
Bernhard Petersch K. D, MED PHYS, P3521
[2]  
Bicas Harley E. A., 2003, Arq. Bras. Oftalmol., V66, P687, DOI 10.1590/S0004-27492003000500026
[3]   A noninvasive eye fixation and computer-aided eye monitoring system for linear accelerator-based stereotactic radiotherapy of uveal melanoma [J].
Bogner, J ;
Petersch, B ;
Georg, D ;
Dieckmann, K ;
Zehetmayer, M ;
Pötter, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (04) :1128-1136
[4]   Bone tissue engineering using 3D printing [J].
Bose, Susmita ;
Vahabzadeh, Sahar ;
Bandyopadhyay, Amit .
MATERIALS TODAY, 2013, 16 (12) :496-504
[5]  
Chauvel P, 1997, FRONT RADIAT THER ON, V30, P133
[6]  
Cruz D. P, ARQUIVOS MED, V23, P45
[7]   LINAC based stereotactic radiotherapy of uveal melanoma:: 4 years clinical experience [J].
Dieckmann, K ;
Georg, D ;
Zehetmayer, M ;
Bogner, J ;
Georgopoulos, M ;
Pötter, R .
RADIOTHERAPY AND ONCOLOGY, 2003, 67 (02) :199-206
[8]   Radiogenic Side Effects After Hypofractionated Stereotactic Photon Radiotherapy of Choroidal Melanoma in 212 Patients Treated Between 1997 and 2007 [J].
Dunavoelgyi, Roman ;
Dieckmann, Karin ;
Gleiss, Andreas ;
Sacu, Stefan ;
Kircher, Karl ;
Georgopoulos, Michael ;
Georg, Dietmar ;
Zehetmayer, Martin ;
Poetter, Richard .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01) :121-128
[9]   LOCAL TUMOR CONTROL, VISUAL ACUITY, AND SURVIVAL AFTER HYPOFRACTIONATED STEREOTACTIC PHOTON RADIOTHERAPY OF CHOROIDAL MELANOMA IN 212 PATIENTS TREATED BETWEEN 1997 AND 2007 [J].
Dunavoelgyi, Roman ;
Dieckmann, Karin ;
Gleiss, Andreas ;
Sacu, Stefan ;
Kircher, Karl ;
Georgopoulos, Michael ;
Georg, Dietmar ;
Zehetmayer, Martin ;
Poetter, Richard .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (01) :199-205
[10]  
Freire J. E, 1997, PRINCIPLES PRACTICE, P871