Quantitative ultrasound parameters in ex-vivo fibrotic rabbit livers: Liver stiffness and tissue microstructure estimation

被引:0
|
作者
Escoffre, Jean-Michel [1 ]
Novell, Anthony [1 ]
Bouakaz, Ayache [1 ]
Benane, Yanis M. [2 ]
Basset, Olivier [2 ]
Franceschini, Emilie [3 ]
机构
[1] Univ Tours, Imagerie & Cerveau, INSERM, Tours, France
[2] Univ Lyon 1, CNRS, Creatis, Inserm,INSA, Lyon, France
[3] Aix Marseille Univ, CNRS, Cent Marseille, LMA, Marseille, France
来源
2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2017年
关键词
STRUCTURE FACTOR MODEL; CELL PELLET BIOPHANTOMS; BACKSCATTER; ATTENUATION; HEPATITIS; FIBROSIS; DISEASE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Liver fibrosis is the common result of chronic liver disease. Diagnosis and grading liver fibrosis for patient management is mainly based on blood tests and hepatic puncture-biopsy, which is particularly invasive. Quantitative UltraSound (QUS) techniques provide insight into tissue microstructure and are based on the frequency-based analysis of the signals from biological tissues. This study aims to explore the diagnostic performance of QUS technique in high frequency (10-40 MHz) for detection of liver fibrosis. The changes in QUS parameters of healthy and fibrotic livers were investigated and were compared to the changes in liver stiffness using shear wave elastography (SWE). Liver fibrosis was induced by subcutaneous injection of CCI4 in the neck of rabbits. Attenuation and backscatter coefficients (BSCs) were estimated using the spectral difference method and the reference phantom method, respectively. Effective scatterer diameter (ESD) and effective acoustic concentration (EAC) were estimated by fitting the measured BSC to an estimated BSC calculated with a spherical Gaussian model. Finally, histopathological analysis of rabbit livers was performed using picrosirius red staining in order to rank the livers according to the Ishak fibrosis staging scale. Rabbit livers were classified on grade 0 (N=3), 2 (N=1), 3 (N=2), 4 (N=3) and 5 (N=2) using histological analysis. Mean attenuation at 40 MHz was higher in fibrotic livers: 0.83 dB/cm/MHz for grades 2 and 3, 0.90 dB/cm/MHz for grades 4 and 5, when compared to 0.59 dB/cm/MHz for healthy livers. Mean ESD estimated in the 10-20 MHz frequency bandwidth was observed to be 24 mu m, 31 mu m and 34 mu m for the healthy liver, for grades 2 and 3, and for grades 4 and 5, respectively. Results showed that the elastic (Young) modulus values were on the order of several thousand of Pascals. The elastic modulus generally increased with the fibrosis grade (scores 2 to 5).
引用
收藏
页数:4
相关论文
共 7 条
  • [1] QUANTITATIVE ULTRASOUND IN EX VIVO FIBROTIC RABBIT LIVERS
    Franceschini, Emilie
    Escoffre, Jean-Michel
    Novell, Anthony
    Auboire, Laurent
    Mendes, Vanda
    Benane, Yanis M.
    Bouakaz, Ayache
    Basset, Olivier
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (07) : 1777 - 1786
  • [2] EX VIVO STUDY OF QUANTITATIVE ULTRASOUND PARAMETERS IN FATTY RABBIT LIVERS
    Ghoshal, Goutam
    Lavarello, Roberto J.
    Kemmerer, Jeremy P.
    Miller, Rita J.
    Oelze, Michael L.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (12) : 2238 - 2248
  • [3] In-vivo study of quantitative ultrasound parameters in fatty rabbit livers
    Nguyen, T.
    Podkowa, A.
    Miller, R. J.
    Oelze, M. L.
    Do, M.
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [4] Ex-vivo expanded CD34+cell transplantation alleviates fibrotic liver injury via innate immune modulation in metabolic dysfunction- associated steatohepatitis mice
    Masuda, Atsutaka
    Nakamura, Toru
    Iwamoto, Hideki
    Suzuki, Hiroyuki
    Sakaue, Takahiko
    Tanaka, Toshimitsu
    Imamura, Yasuko
    Mori, Nobuyuki
    Koga, Hironori
    Kawaguchi, Takumi
    CYTOTHERAPY, 2024, 26 (08) : 899 - 909
  • [5] Reliability Analysis of Acoustic Radiation Force Impulse Ultrasound Imaging With Virtual Touch Tissue Quantification Ex Vivo Ox Liver
    Yang, Long
    Yuan, Jianjun
    Wang, Qi
    Wu, Gang
    Guo, Wen-Qing
    Wang, Wen-Wei
    Zhao, Bing
    ULTRASOUND QUARTERLY, 2015, 31 (01) : 59 - 62
  • [6] Quantitative ultrasound techniques for assessing thermal ablation: Measurement of the backscatter coefficient from ex vivo human liver
    Rohfritsch, Adrien
    Franceschini, Emilie
    Dupre, Aurelien
    Melodelima, David
    MEDICAL PHYSICS, 2023, 50 (11) : 6908 - 6919
  • [7] Ex Vivo Demonstration of a Novel Dual-Frequency Ultrasound Method for Quantitative Measurements of Liver Fat Content
    Berg, Sigrid
    Amini, Naseh
    Solberg, Stian
    Kulseng, Eirik
    Odega, Ronnaug Astri
    Fossmark, Reidar
    Muller, Sebastien
    Kulseng, Bard Eirik
    Dankel, Simon Nitter
    Mjones, Patricia
    Berge, Rolf K.
    Hansen, Rune
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2025, 51 (01) : 159 - 168