A straightforward electrochemical deposition process was developed to grow gold nanostructures, including nanocoral, nanothorn, branched belt, and nanoparticle, on carbon electrodes by reducing HAuCl4 under constant potentials in mixtures containing CTAC and/or NaNO3. Among the nanostructures, the quasi-one-dimensional nanocoral electrode showed the highest surface area. Because of this, it provided excellent electrochemical performances in cyclic voltammetric (CV) studies for kinetic-controlled enzyme-free glucose oxidation reactions. In amperometric studies carried out at 0.200 V in PBS (pH 7.40, 0.100 M), the nanocoral electrode showed the highest anodic current response. It also offered the greatest sensitivity, 22.6 mu AmM(-1)cm(-2), an extended linear range, 5.00 x 10(-2) mM to 3.00 x 10(1) mM, and a low detection limit, 1.00 x 10(1) mu m among the electrodes investigated in this study. In addition, the glucose oxidation by the nanocoral electrode started at -0.280 V. more negative than the one of using a commercial Au electrode as the working electrode. This is attributed to the presence of exposed Au (110) surfaces on the electrode. The feature was applied to oxidize glucose selectively in the presence of ascorbic acid (AA) and uric acid (UA), common interferences found in physiological analytes. With an applied voltage at -0.100 V. the AA oxidation (started at -0.080 V) can be avoided while the glucose oxidation still provides a significant response.
引用
收藏
页码:2773 / 2780
页数:8
相关论文
共 37 条
  • [31] Nonenzymatic electrochemical glucose sensor based on nanoporous PtPb networks
    Wang, Jingpeng
    Thomas, Dan F.
    Chen, Aicheng
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (04) : 997 - 1004
  • [32] Enzyme based biosensors for in vivo measurements
    Wilson, GS
    Hu, YB
    [J]. CHEMICAL REVIEWS, 2000, 100 (07) : 2693 - 2704
  • [33] GLUCOSE-OXIDASE - AN IDEAL ENZYME
    WILSON, R
    TURNER, APF
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (03) : 165 - 185
  • [34] Highly ordered platinum-nanotubule arrays for amperometric glucose sensing
    Yuan, JH
    Wang, K
    Xia, XH
    [J]. ADVANCED FUNCTIONAL MATERIALS, 2005, 15 (05) : 803 - 809
  • [35] A glucose biosensor employing a stable artificial peroxidase based on ruthenium purple anchored cinder
    Zen, JM
    Kumar, AS
    Chung, CR
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (11) : 2703 - 2709
  • [36] Fabrication, characterization and application of gold nano-structured film
    Zhao, Wei
    Xu, Jing-Juan
    Shi, Chuan-Guo
    Chen, Hong-Yuan
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (05) : 773 - 778
  • [37] Gold nanoparticles integrated in a nanotube array for electrochemical detection of glucose
    Zhou, Yi-Ge
    Yang, Si
    Qian, Qing-Yun
    Xia, Xing-Hua
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (01) : 216 - 219