Evidence-based Danish guidelines for screening of diabetic retinopathy

被引:57
作者
Grauslund, Jakob [1 ,2 ,3 ]
Andersen, Nis [1 ,4 ]
Andresen, Jens [1 ,4 ]
Flesner, Per [1 ,4 ]
Haamann, Per [1 ,4 ]
Heegaard, Steffen [1 ,5 ]
Larsen, Michael [1 ,5 ]
Laugesen, Caroline Schmidt [1 ,6 ]
Schielke, Katja [1 ,7 ]
Skov, Jesper [1 ,4 ]
Bek, Toke [1 ,8 ]
机构
[1] Danish Ophthalmol Soc, Copenhagen, Denmark
[2] Odense Univ Hosp, Dept Ophthalmol, Sdr Blvd 29, DK-5000 Odense C, Denmark
[3] Univ Southern Denmark, Dept Clin Res, Odense, Denmark
[4] Org Danish Ophthalmologists, Copenhagen, Denmark
[5] Rigshosp Glostrup, Dept Ophthalmol, Copenhagen, Denmark
[6] Zealand Univ Hosp Roskilde, Dept Ophthalmol, Roskilde, Denmark
[7] Aalborg Univ Hosp, Dept Ophthalmol, Aalborg, Denmark
[8] Aarhus Univ Hosp, Dept Ophthalmol, Aarhus, Denmark
关键词
diabetic retinopathy; screening; guideline; evidence; proliferative diabetic retinopathy; clinically significant diabetic macular oedema; SCANNING LASER OPHTHALMOSCOPY; MACULAR EDEMA; FUNDUS PHOTOGRAPHY; BARIATRIC SURGERY; RISK-ASSESSMENT; PREVALENCE; INTERVALS; PROGRESSION; IMPACT; COMPLICATIONS;
D O I
10.1111/aos.13936
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Diabetic retinopathy (DR) is among the leading causes of visual loss in the working-age population. It is generally accepted that screening of DR is cost-effective and can detect DR before it becomes sight-threatening to allow timely treatment. Methods A group of retinal specialists was formed by the Danish Ophthalmological Society with the aim to formulate contemporary evidence-based guidelines for screening of DR in order to implement these in the Danish screening system. Results We hereby present evidence for DR-screening regarding (1) classification of DR, (2) examination techniques, (3) screening intervals and (4) automated screening. It is our recommendation that the International Clinical Retinopathy Disease Severity Scale should be used to classify DR. As a minimum, mydriatic two-field disc- and macular-centred images are required. In the case of suspected clinically significant diabetic macular oedema, supplementary optical coherence tomography can increase the diagnostic accuracy. There is solid evidence to support a flexible, individualized screening regimen. In particular, it is possible to prolong screening intervals to 24-48 months for patients with no or mild nonproliferative diabetic retinopathy (NPDR), but it is also possible to use extended intervals of 12-24 months for patients with moderate NPDR given that these are well-regulated regarding glycaemic control (HbA1c <= 53 mmol/mol) and blood pressure (<= 130/80 mmHg). Automated screening of DR is encouraging but is not ready for implementation at present. Conclusion Danish evidenced-based guidelines for screening of DR support high-quality imaging and allow flexible, individualized screening intervals with a potential for extension to patients with low risk of DR progression.
引用
收藏
页码:763 / 769
页数:7
相关论文
共 64 条
[1]   Improved Automated Detection of Diabetic Retinopathy on a Publicly Available Dataset Through Integration of Deep Learning [J].
Abramoff, Michael David ;
Lou, Yiyue ;
Erginay, Ali ;
Clarida, Warren ;
Amelon, Ryan ;
Folk, James C. ;
Niemeijer, Meindert .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (13) :5200-5206
[2]   Adopting 3-Year Screening Intervals for Sight-Threatening Retinal Vascular Lesions in Type 2 Diabetic Subjects Without Retinopathy [J].
Agardh, Elisabet ;
Tababat-Khani, Poya .
DIABETES CARE, 2011, 34 (06) :1318-1319
[3]   METHODOLOGY FOR RETINAL PHOTOGRAPHY AND ASSESSMENT OF DIABETIC-RETINOPATHY - THE EURODIAB IDDM COMPLICATIONS STUDY [J].
ALDINGTON, SJ ;
KOHNER, EM ;
MEUER, S ;
KLEIN, R ;
SJOLIE, AK .
DIABETOLOGIA, 1995, 38 (04) :437-444
[4]   The Danish Registry of Diabetic Retinopathy [J].
Andersen, Nis ;
Hjortdal, Jesper Ostergaard ;
Schielke, Katja Christina ;
Bek, Toke ;
Grauslund, Jakob ;
Laugesen, Caroline Schmidt ;
Lund-Andersen, Henrik ;
Cerqueira, Charlotte ;
Andresen, Jens .
CLINICAL EPIDEMIOLOGY, 2016, 8 :613-619
[5]  
[Anonymous], 1991, OPHTHALMOLOGY, V98, P786
[6]  
[Anonymous], 1976, Am J Ophthalmol, V81, P383
[7]  
[Anonymous], 2009, ISO 10940:2009
[8]  
[Anonymous], INT J ENV RES PUBLIC
[9]  
[Anonymous], INVEST OPHTHALMOL VI
[10]  
[Anonymous], NHS DIAB EYE SCREEN