Flow Diverter in Unruptured Intracranial Vertebral Artery Dissecting Aneurysm

被引:8
|
作者
Oh, Han San [1 ]
Bae, Jin Woo [2 ]
Hong, Chang-eui [3 ]
Kim, Kang Min [1 ]
Yoo, Dong Hyun [4 ]
Kang, Hyun-Seung [1 ]
Cho, Young Dae [4 ]
机构
[1] Seoul Natl Univ, Seoul Natl Univ Hosp, Dept Neurosurg, Coll Med, Seoul, South Korea
[2] Inha Univ Hosp, Dept Neurosurg, Incheon, South Korea
[3] Vet Hlth Serv Med Ctr, Dept Neurosurg, Seoul, South Korea
[4] Seoul Natl Univ, Seoul Natl Univ Hosp, Dept Radiol, Coll Med, Seoul, South Korea
来源
FRONTIERS IN NEUROLOGY | 2022年 / 13卷
关键词
aneurysm; vertebral artery; dissection; reconstructive; flow diverter; PIPELINE EMBOLIZATION DEVICE; ENDOVASCULAR TREATMENT; COIL EMBOLIZATION; FOLLOW-UP; OUTCOMES; STENT;
D O I
10.3389/fneur.2022.912863
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
ObjectiveIntracranial vertebral artery dissecting aneurysm (VADA) may present as aneurysmal dilation alone, dilation with coexisting stenosis, or, in some cases, as a recurrent aneurysm after previous reconstructive treatment. To date, the clinical utility of flow diverters in VADA has not been examined according to these various circumstances. This study aims to report the safety and efficacy of flow diverters in the treatment of various manifestations of intracranial VADA. MethodsA total of 26 patients and 27 VADAs treated with flow diverting stents from November 2014 to September 2021 were included. Medical records and radiologic data were analyzed to assess the safety and efficacy of flow diverting stents. ResultsThe results showed that 12 cases (44.4%) presented with aneurysmal dilation only, 7 (26.0%) with aneurysmal dilation and one or more associated stenotic lesions, and 8 (29.6%) as recurrence after previous treatment, including stent-assisted coil embolization (n = 5), single stent only (n = 1), and coil embolization without stent (n = 2). Among 27 lesions, 25 were treated with single flow diverters; additional flow diverting stents were required in 2 cases because of incomplete coverage of the aneurysm neck. There was one instance of incomplete expansion of the flow diverter. All cases showed contrast stagnation in the aneurysmal sac immediately after deployment of the flow diverting stent, and during a mean follow-up period of 18.6 months (range 6 to 60), the overall complete occlusion rate was 55.6%, with complete occlusion of 83.3% of aneurysmal dilation only lesions, 42.9% of aneurysms with stenosis, and 25% of the recurrent aneurysm. Only two patients (7.7%) had delayed ischemic complications. ConclusionFlow diverters have proven safe and effective in unruptured VADA. However, the complete occlusion rate with the flow diverter is relatively lower in VADA with stenosis or with previous stent placement than in dilation-only lesions. Further study with a larger cohort would be needed to confirm these results.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Flow Diverter Devices for the Treatment of Unruptured Vertebral Artery Dissecting Aneurysm
    Kim, Chang Hyeun
    Lee, Chi Hyung
    Kim, Young Ha
    Sung, Soon Ki
    Son, Dong Wuk
    Lee, Sang Weon
    Song, Geun Sung
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2021, 64 (06) : 891 - 900
  • [2] Flow diverter treatment of intracranial vertebral artery dissecting pseudoaneurysms
    Cerejo, Russell
    Bain, Mark
    Moore, Nina
    Hardman, Julian
    Bauer, Andrew
    Hussain, M. Shazam
    Masaryk, Thomas
    Rasmussen, Peter
    Toth, Gabor
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (11) : 1064 - 1068
  • [3] Flow diverters versus stent-assisted coiling in unruptured intracranial vertebral artery dissecting aneurysms
    Han, Jiangli
    Tong, Xin
    Han, Mingyang
    Peng, Fei
    Niu, Hao
    Liu, Fei
    Liu, Aihua
    JOURNAL OF NEUROSURGERY, 2023, 140 (04) : 1064 - 1070
  • [4] Flow-Diverting Stent for Ruptured Intracranial Dissecting Aneurysm of Vertebral Artery
    Narata, Ana Paula
    Yilmaz, Hasan
    Schaller, Karl
    Lovblad, Karl Olof
    Pereira, Vitor Mendes
    NEUROSURGERY, 2012, 70 (04) : 982 - 988
  • [5] Flow diverter for the treatment of large (> 10 mm) vertebral artery dissecting aneurysms
    Lee, Woosung
    Han, Hyun Jin
    Kim, Junhyung
    Park, Keun Young
    Kim, Yong Bae
    Jang, Chang Ki
    Chung, Joonho
    ACTA NEUROCHIRURGICA, 2022, 164 (05) : 1247 - 1254
  • [6] Management of ruptured and unruptured intracranial vertebral artery dissecting aneurysms
    Su, Wandong
    Gou, Shouzhong
    Ni, Shilei
    Li, Gang
    Liu, Yuguang
    Zhu, Shugan
    Li, Xingang
    JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (12) : 1639 - 1644
  • [7] Evaluation of flow diverter use in acutely ruptured vertebral artery dissecting Aneurysms: A focus on safety and efficacy for rapid Aneurysm obliteration
    Duangprasert, Gahn
    Sukhor, Sasikan
    Ratanavinitkul, Warot
    Tantongtip, Dilok
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2024, 242
  • [8] Flow diverters in the treatment of unruptured vertebral artery dissecting aneurysm: A single-center experience
    Lu, Xiaoyang
    Zhang, Yuansheng
    Zhou, Hu
    Jian, Lipeng
    Yin, Shi
    Li, Tao
    Huang, Wei
    FRONTIERS IN NEUROLOGY, 2023, 14
  • [9] The Use of Flow Diverter in Ruptured, Dissecting Intracranial Aneurysms of the Posterior Circulation
    Maus, Volker
    Mpotsaris, Anastasios
    Dorn, Franziska
    Moehlenbruch, Markus
    Borggrefe, Jan
    Stavrinou, Pantelis
    Abdullayev, Nuran
    Barnikol, Utako Birgit
    Liebig, Thomas
    Kabbasch, Christoph
    WORLD NEUROSURGERY, 2018, 111 : E424 - E433
  • [10] Flow Diverter Treatment Using a Flow Re-Direction Endoluminal Device for Unruptured Intracranial Vertebral Artery Dissecting Aneurysm: Single-Center Case Series and Technical Considerations
    Phd, Dae Chul Suh Md
    Song, Yunsun
    Park, Sang Ik
    Kwon, Boseong
    NEUROINTERVENTION, 2023, 18 (02) : 114 - +