Steps toward the percutaneous replacement of atrioventricular valves - An experimental study

被引:85
作者
Boudjemline, Y
Agnoletti, G
Bonnet, D
Behr, L
Borenstein, N
Sidi, D
Bonhoeffer, P
机构
[1] Hop Necker Enfants Malad, Serv Cardiol Pediat, F-75015 Paris, France
[2] Inst Mutualiste Montsouris, Fac Necker, Paris, France
[3] Inst Mutualiste Montsouris, IMM Rech, Paris, France
[4] Great Ormond St Hosp Sick Children, Cardiothorac Unit, London, England
关键词
D O I
10.1016/j.jacc.2005.01.063
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The goal of this study was to develop a device for percutaneous replacement of the tricuspid valve in animals. BACKGROUND Percutaneous valve replacement has recently been introduced, and early clinical experience has been reported. To date, this technique is limited to the replacement of pulmonary and aortic valves in selected patients. METHODS A newly designed nitinol stent, forming two large disks separated by a cylinder with a diameter of 18 mm, was specially designed for the purpose of this study. An 18-mm bovine valve was mounted in the central part of the stent, and a polytetrafluoroethylene membrane was sutured onto the ventricular disk. Eight ewes were equally divided into two groups (group 1, acute study; group 2, killed at one month). RESULTS Seven of eight devices were successfully delivered in the desired position. In one animal, the device was trapped in tricuspid cordae, leading to its incomplete opening. A significant paravalvular leak was noticed in one animal of group 2. Mean right atrial pressure increased from 5 to 7 mm Hg and did not change during the follow-up. At autopsy, examination confirmed the good position of devices in successfully implanted animals. CONCLUSIONS Implantation of a semi-lunar valve in the tricuspid position is possible in ewes through a transcatheter approach. A disk-based nitinol stent is needed to allow valve implantation in the atrioventricular position. These studies open new perspectives into tricuspid as well as mitral valve replacement. (c) 2005 by the American College of Cardiology Foundation.
引用
收藏
页码:360 / 365
页数:6
相关论文
共 9 条
  • [1] Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction
    Bonhoeffer, P
    Boudjemline, Y
    Saliba, Z
    Merckx, J
    Aggoun, Y
    Bonnet, D
    Acar, P
    Le Bidois, J
    Sidi, D
    Kachaner, J
    [J]. LANCET, 2000, 356 (9239) : 1403 - 1405
  • [2] Transcatheter implantation of a bovine valve in pulmonary position - A lamb study
    Bonhoeffer, P
    Boudjemline, Y
    Saliba, Z
    Hausse, AO
    Aggoun, Y
    Bonnet, D
    Sidi, D
    Kachaner, J
    [J]. CIRCULATION, 2000, 102 (07) : 813 - 816
  • [3] Percutaneous insertion of the pulmonary valve
    Bonhoeffer, P
    Boudjemline, Y
    Qureshi, SA
    Le Bidois, J
    Iserin, L
    Acar, P
    Merckx, J
    Kachaner, J
    Sidi, D
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (10) : 1664 - 1669
  • [4] Steps toward percutaneous aortic valve replacement
    Boudjemline, Y
    Bonhoeffer, P
    [J]. CIRCULATION, 2002, 105 (06) : 775 - 778
  • [5] Percutaneous implantation of a valve in the descending aorta in lambs
    Boudjemline, Y
    Bonhoeffer, P
    [J]. EUROPEAN HEART JOURNAL, 2002, 23 (13) : 1045 - 1049
  • [6] Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description
    Cribier, A
    Eltchaninoff, H
    Bash, A
    Borenstein, N
    Tron, C
    Bauer, F
    Derumeaux, G
    Anselme, F
    Laborde, F
    Leon, MB
    [J]. CIRCULATION, 2002, 106 (24) : 3006 - 3008
  • [7] *EUR CONV PROT AN, 1999, OFFICIAL J EUROPEA L, V222
  • [8] Percutaneous mitral valve repair: A feasibility study in an ovine model of acute ischemic mitral regurgitation
    Liddicoat, JR
    Mac Neill, BD
    Gillinov, AM
    Cohn, WE
    Chin, CH
    Prado, AD
    Pandian, NG
    Oesterle, SN
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (03) : 410 - 416
  • [9] Endovascular edge-to-edge mitral valve repair - Short-term results in a porcine model
    St Goar, FG
    Fann, JI
    Komtebedde, J
    Foster, E
    Oz, MC
    Fogarty, TJ
    Feldman, T
    Block, PC
    [J]. CIRCULATION, 2003, 108 (16) : 1990 - 1993