Geometrical and Monte Carlo projectors in 3D PET reconstruction

被引:37
作者
Aguiar, Pablo [1 ]
Rafecas, Magdalena [2 ]
Enrique Ortuno, Juan [3 ]
Kontaxakis, George [3 ]
Santos, Andres [3 ]
Pavia, Javier [4 ]
Ros, Domenec [5 ]
机构
[1] Univ Santiago de Compostela, Dept Fis Particulas, Complexo Hosp Univ Santiago de Compostela, Fdn IDICHUS IDIS, Santiago De Compostela, Spain
[2] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain
[3] Univ Politecn Madrid, Dept Ingn Elect, E-28040 Madrid, Spain
[4] Hosp Clin Barcelona, IDIBAPS, Serv Med Nucl, Barcelona, Spain
[5] Univ Barcelona, IDIBAPS, Fac Med, Unitat Biofis, E-08007 Barcelona, Spain
关键词
3D PET; iterative reconstruction; list-mode reconstruction; ray-tracing techniques; Monte Carlo simulation; system response matrix; ITERATIVE IMAGE-RECONSTRUCTION; SYSTEM MATRIX; SCATTER; SIMULATION; ALGORITHM; IMPLEMENTATION; MODEL; EM;
D O I
10.1118/1.3501884
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the present work, the authors compare geometrical and Monte Carlo projectors in detail. The geometrical projectors considered were the conventional geometrical Siddon ray-tracer (S-RT) and the orthogonal distance-based ray-tracer (OD-RT), based on computing the orthogonal distance from the center of image voxel to the line-of-response. A comparison of these geometrical projectors was performed using different point spread function (PSF) models. The Monte Carlo-based method under consideration involves an extensive model of the system response matrix based on Monte Carlo simulations and is computed off-line and stored on disk. Methods: Comparisons were performed using simulated and experimental data of the commercial small animal PET scanner rPET. Results: The results demonstrate that the orthogonal distance-based ray-tracer and Siddon ray-tracer using PSF image-space convolutions yield better images in terms of contrast and spatial resolution than those obtained after using the conventional method and the multiray-based S-RT. Furthermore, the Monte Carlo-based method yields slight improvements in terms of contrast and spatial resolution with respect to these geometrical projectors. Conclusions: The orthogonal distance-based ray-tracer and Siddon ray-tracer using PSF image-space convolutions represent satisfactory alternatives to factorizing the system matrix or to the conventional on-the-fly ray-tracing methods for list-mode reconstruction, where an extensive modeling based on Monte Carlo simulations is unfeasible. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3501884]
引用
收藏
页码:5691 / 5702
页数:12
相关论文
共 42 条
[41]  
Zaidi H, 2003, J NUCL MED, V44, P291
[42]   Fast and memory-efficient Monte Carlo-based image reconstruction for whole-body PET [J].
Zhang, Long ;
Staelens, Steven ;
Van Holen, Roel ;
De Beenhouwer, Jan ;
Verhaeghe, Jeroen ;
Kawrakow, Iwan ;
Vandenberghe, Stefaan .
MEDICAL PHYSICS, 2010, 37 (07) :3667-3676