Geometrical and Monte Carlo projectors in 3D PET reconstruction

被引:36
作者
Aguiar, Pablo [1 ]
Rafecas, Magdalena [2 ]
Enrique Ortuno, Juan [3 ]
Kontaxakis, George [3 ]
Santos, Andres [3 ]
Pavia, Javier [4 ]
Ros, Domenec [5 ]
机构
[1] Univ Santiago de Compostela, Dept Fis Particulas, Complexo Hosp Univ Santiago de Compostela, Fdn IDICHUS IDIS, Santiago De Compostela, Spain
[2] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain
[3] Univ Politecn Madrid, Dept Ingn Elect, E-28040 Madrid, Spain
[4] Hosp Clin Barcelona, IDIBAPS, Serv Med Nucl, Barcelona, Spain
[5] Univ Barcelona, IDIBAPS, Fac Med, Unitat Biofis, E-08007 Barcelona, Spain
关键词
3D PET; iterative reconstruction; list-mode reconstruction; ray-tracing techniques; Monte Carlo simulation; system response matrix; ITERATIVE IMAGE-RECONSTRUCTION; SYSTEM MATRIX; SCATTER; SIMULATION; ALGORITHM; IMPLEMENTATION; MODEL; EM;
D O I
10.1118/1.3501884
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the present work, the authors compare geometrical and Monte Carlo projectors in detail. The geometrical projectors considered were the conventional geometrical Siddon ray-tracer (S-RT) and the orthogonal distance-based ray-tracer (OD-RT), based on computing the orthogonal distance from the center of image voxel to the line-of-response. A comparison of these geometrical projectors was performed using different point spread function (PSF) models. The Monte Carlo-based method under consideration involves an extensive model of the system response matrix based on Monte Carlo simulations and is computed off-line and stored on disk. Methods: Comparisons were performed using simulated and experimental data of the commercial small animal PET scanner rPET. Results: The results demonstrate that the orthogonal distance-based ray-tracer and Siddon ray-tracer using PSF image-space convolutions yield better images in terms of contrast and spatial resolution than those obtained after using the conventional method and the multiray-based S-RT. Furthermore, the Monte Carlo-based method yields slight improvements in terms of contrast and spatial resolution with respect to these geometrical projectors. Conclusions: The orthogonal distance-based ray-tracer and Siddon ray-tracer using PSF image-space convolutions represent satisfactory alternatives to factorizing the system matrix or to the conventional on-the-fly ray-tracing methods for list-mode reconstruction, where an extensive modeling based on Monte Carlo simulations is unfeasible. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3501884]
引用
收藏
页码:5691 / 5702
页数:12
相关论文
共 42 条
  • [1] AGUIAR P, 2007, INT M FULL 3D UNPUB, P402
  • [2] Attenuation correction for PET using count-limited transmission images reconstructed with median root prior
    Alenius, S
    Ruotsalainen, U
    Astola, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 646 - 651
  • [3] Modeling and incorporation of system response functions in 3-D whole body PET
    Alessio, Adam M.
    Kinahan, Paul E.
    Lewellen, Thomas K.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) : 828 - 837
  • [4] Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction
    Alessio, Adam M.
    Stearns, Charles W.
    Tong, Shan
    Ross, Steven G.
    Kohlmyer, Steve
    Ganin, Alex
    Kinahan, Paul E.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (03) : 938 - 949
  • [5] [Anonymous], SINGLE SCATTER SIMUL
  • [6] Implementation and evaluation of a 3D one-step late reconstruction algorithm for 3D positron emission tomography brain studies using median root prior
    Bettinardi, V
    Pagani, E
    Gilardi, MC
    Alenius, S
    Thielemans, K
    Teras, M
    Fazio, F
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2002, 29 (01) : 7 - 18
  • [7] Molecular imaging of small animals with dedicated PET tomographs
    Chatziioannou, AF
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2002, 29 (01) : 98 - 114
  • [8] Cherry S. R., 2012, Physics in Nuclear Medicine
  • [9] Quantitative comparison of FBP, EM, and Bayesian reconstruction algorithms for the IndyPET scanner
    Frese, T
    Rouze, NC
    Bouman, CA
    Sauer, K
    Hutchins, GD
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (02) : 258 - 276
  • [10] Performance analysis of a low-cost small animal PET/SPECT scanner
    Guerra, Pedro
    Rubio, Jose L.
    Ortuno, Juan E.
    Kontaxakis, Georgios
    Ledesma, Maria J.
    Santos, Andres
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) : 98 - 101