Geometrical and Monte Carlo projectors in 3D PET reconstruction

被引:37
作者
Aguiar, Pablo [1 ]
Rafecas, Magdalena [2 ]
Enrique Ortuno, Juan [3 ]
Kontaxakis, George [3 ]
Santos, Andres [3 ]
Pavia, Javier [4 ]
Ros, Domenec [5 ]
机构
[1] Univ Santiago de Compostela, Dept Fis Particulas, Complexo Hosp Univ Santiago de Compostela, Fdn IDICHUS IDIS, Santiago De Compostela, Spain
[2] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain
[3] Univ Politecn Madrid, Dept Ingn Elect, E-28040 Madrid, Spain
[4] Hosp Clin Barcelona, IDIBAPS, Serv Med Nucl, Barcelona, Spain
[5] Univ Barcelona, IDIBAPS, Fac Med, Unitat Biofis, E-08007 Barcelona, Spain
关键词
3D PET; iterative reconstruction; list-mode reconstruction; ray-tracing techniques; Monte Carlo simulation; system response matrix; ITERATIVE IMAGE-RECONSTRUCTION; SYSTEM MATRIX; SCATTER; SIMULATION; ALGORITHM; IMPLEMENTATION; MODEL; EM;
D O I
10.1118/1.3501884
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the present work, the authors compare geometrical and Monte Carlo projectors in detail. The geometrical projectors considered were the conventional geometrical Siddon ray-tracer (S-RT) and the orthogonal distance-based ray-tracer (OD-RT), based on computing the orthogonal distance from the center of image voxel to the line-of-response. A comparison of these geometrical projectors was performed using different point spread function (PSF) models. The Monte Carlo-based method under consideration involves an extensive model of the system response matrix based on Monte Carlo simulations and is computed off-line and stored on disk. Methods: Comparisons were performed using simulated and experimental data of the commercial small animal PET scanner rPET. Results: The results demonstrate that the orthogonal distance-based ray-tracer and Siddon ray-tracer using PSF image-space convolutions yield better images in terms of contrast and spatial resolution than those obtained after using the conventional method and the multiray-based S-RT. Furthermore, the Monte Carlo-based method yields slight improvements in terms of contrast and spatial resolution with respect to these geometrical projectors. Conclusions: The orthogonal distance-based ray-tracer and Siddon ray-tracer using PSF image-space convolutions represent satisfactory alternatives to factorizing the system matrix or to the conventional on-the-fly ray-tracing methods for list-mode reconstruction, where an extensive modeling based on Monte Carlo simulations is unfeasible. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3501884]
引用
收藏
页码:5691 / 5702
页数:12
相关论文
共 42 条
[1]  
AGUIAR P, 2007, INT M FULL 3D UNPUB, P402
[2]   Attenuation correction for PET using count-limited transmission images reconstructed with median root prior [J].
Alenius, S ;
Ruotsalainen, U ;
Astola, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :646-651
[3]   Modeling and incorporation of system response functions in 3-D whole body PET [J].
Alessio, Adam M. ;
Kinahan, Paul E. ;
Lewellen, Thomas K. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) :828-837
[4]   Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction [J].
Alessio, Adam M. ;
Stearns, Charles W. ;
Tong, Shan ;
Ross, Steven G. ;
Kohlmyer, Steve ;
Ganin, Alex ;
Kinahan, Paul E. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (03) :938-949
[5]  
[Anonymous], SINGLE SCATTER SIMUL
[6]   Implementation and evaluation of a 3D one-step late reconstruction algorithm for 3D positron emission tomography brain studies using median root prior [J].
Bettinardi, V ;
Pagani, E ;
Gilardi, MC ;
Alenius, S ;
Thielemans, K ;
Teras, M ;
Fazio, F .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2002, 29 (01) :7-18
[7]   Molecular imaging of small animals with dedicated PET tomographs [J].
Chatziioannou, AF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2002, 29 (01) :98-114
[8]  
Cherry S. R., 2012, Physics in Nuclear Medicine
[9]   Quantitative comparison of FBP, EM, and Bayesian reconstruction algorithms for the IndyPET scanner [J].
Frese, T ;
Rouze, NC ;
Bouman, CA ;
Sauer, K ;
Hutchins, GD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (02) :258-276
[10]   Performance analysis of a low-cost small animal PET/SPECT scanner [J].
Guerra, Pedro ;
Rubio, Jose L. ;
Ortuno, Juan E. ;
Kontaxakis, Georgios ;
Ledesma, Maria J. ;
Santos, Andres .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) :98-101