Visibility of bony structures around hip prostheses in dual-energy CT: With or without metal artefact reduction software

被引:7
作者
Jeong, Jewon [1 ]
Kim, Hyun-joo [1 ]
Oh, Eunsun [1 ]
Cha, Jang Gyu [2 ]
Hwang, Jiyoung [1 ]
Hong, Seong Sook [1 ]
Chang, Yun Woo [1 ]
机构
[1] Soonchunhyang Univ, Seoul Hosp, Daesagwanro 59, Seoul 04401, South Korea
[2] Soonchunhyang Univ, Bucheon Hosp, Bucheonsi, Gyeonggido, South Korea
关键词
CT-dual energy; metal artefact reduction software; metal hip prostheses; REVISION TOTAL HIP; MRI GRADING SYSTEM; UNITED-STATES; FOLLOW-UP; REPLACEMENT; ARTHROPLASTY; EPIDEMIOLOGY; TOMOGRAPHY; PREVALENCE; FRACTURES;
D O I
10.1111/1754-9485.12746
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The development of dual-energy CT and metal artefact reduction software provides a further chance of reducing metal-related artefacts. However, there have been only a few studies regarding whether MARs practically affect visibility of structures around a metallic hip prosthesis on post-operative CT evaluation. Methods: Twenty-seven patients with 42 metallic hip prostheses underwent DECT. The datasets were reconstructed with 70, 90 and 110 keV with and without MARs. The areas were classified into 10 zones according to the reference zone. All the images were reviewed in terms of the severity of the beam-hardening artefacts, differentiation of the bony cortex and trabeculae and visualization of trabecular patterns with a three-point scale. The metallic screw diameter was measured in the acetabulum with 110 keV images. Results: The scores were the worst on 70 keV images without MARs [mean scores:1.84-4.22 (p < 0.001-1.000)]. The structures in zone II were best visualized on 110 keV (p < 0.001-0.011, mean scores: 2.86-5.22). In other zones, there is general similarity in mean scores whether applying MARs or not (p < 0.001-0.920). The mean diameter of the screw was 5.85 mm without MARs and 3.44 mm with MARs (mean reference diameter: 6.48 mm). Conclusion: The 110 keV images without MARs are best for evaluating acetabular zone II. The visibility of the bony structures around the hip prosthesis is similar in the other zones with or without MARs regardless of key. MARS may not be needed for the evaluation of the metallic hip prosthesis itself at sufficient high-energy levels; however, MARS still has a role in the evaluation of other soft tissues around the prosthesis.
引用
收藏
页码:634 / 641
页数:8
相关论文
共 27 条
[1]   Survival following total hip replacement [J].
Barrett, J ;
Losina, E ;
Baron, JA ;
Mahomed, NN ;
Wright, J ;
Katz, JN .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09) :1965-1971
[2]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[3]  
Bloch B, 2015, ACTA ORTHOP BELG, V81, P225
[4]   The Epidemiology of Revision Total Hip Arthroplasty in the United States [J].
Bozic, Kevin J. ;
Kurtz, Steven M. ;
Lau, Edmund ;
Ong, Kevin ;
Vail, Thomas P. ;
Berry, Daniel J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01) :128-133
[5]   Incidence and Mortality of Hip Fractures in the United States [J].
Brauer, Carmen A. ;
Coca-Perraillon, Marcelo ;
Cutler, David M. ;
Rosen, Allison B. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 302 (14) :1573-1579
[6]   Incidence and economic burden of osteoporosis-related fractures in the United States, 2005-2025 [J].
Burge, Russel ;
Dawson-Hughes, Bess ;
Solomon, Daniel H. ;
Wong, John B. ;
King, Alison ;
Tosteson, Anna .
JOURNAL OF BONE AND MINERAL RESEARCH, 2007, 22 (03) :465-475
[7]   CT and MRI of hip arthroplasty [J].
Cahir, J. G. ;
Toms, A. P. ;
Marshall, T. J. ;
Wimhurst, J. ;
Nolan, J. .
CLINICAL RADIOLOGY, 2007, 62 (12) :1163-1171
[8]   Metal Artifact Reduction Software Used With Abdominopelvic Dual- Energy CT of Patients With Metal Hip Prostheses: Assessment of Image Quality and Clinical Feasibility [J].
Han, Seung Chol ;
Chung, Yong Eun ;
Lee, Young Han ;
Park, Kwan Kyu ;
Kim, Myeong Jin ;
Kim, Ki Whang .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (04) :788-795
[9]   New MRI Grading System for the Cervical Canal Stenosis [J].
Kang, Yusuhn ;
Lee, Joon Woo ;
Koh, Young Hwan ;
Hur, Saebeom ;
Kim, Su Jin ;
Chai, Jee Won ;
Kang, Heung Sik .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (01) :W134-W140
[10]   Low rate of total hip replacement as reflected by a low prevalence of hip osteoarthritis in South Korea [J].
Kim, H. A. ;
Koh, S. H. ;
Lee, B. ;
Kim, I. J. ;
Seo, Y. I. ;
Song, Y. W. ;
Hunter, D. J. ;
Zhang, Y. .
OSTEOARTHRITIS AND CARTILAGE, 2008, 16 (12) :1572-1575