Predicting appropriate shocks in patients with heart failure: Patient levelmeta-analysis from SCD-HeFT and MADIT II

被引:22
作者
Zeitler, Emily P. [1 ]
Al-Khatib, Sana M. [1 ,2 ]
Friedman, Daniel J. [1 ,2 ]
Han, Joo Yoon [3 ]
Poole, Jeanne E. [3 ]
Bardy, Gust H. [3 ]
Bigger, J. Thomas [4 ]
Buxton, Alfred E. [6 ]
Moss, Arthur J. [5 ]
Lee, Kerry L. [2 ]
Dorian, Paul [7 ]
Cappato, Riccardo [8 ,9 ]
Kadish, Alan H. [10 ]
Kudenchuk, Peter J. [3 ]
Mark, Daniel B. [1 ,2 ]
Inoue, Lurdes Y. T. [3 ]
Sanders, Gillian D. [2 ]
机构
[1] Duke Univ Hosp, Durham, NC USA
[2] Duke Clin Res Inst, Duke Box 3485,7020 North Pavil Bldg, Durham, NC 27710 USA
[3] Univ Washington, Seattle, WA 98195 USA
[4] Columbia Univ, New York, NY USA
[5] Univ Rochester, Rochester, NY USA
[6] Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[7] Univ Toronto, Toronto, ON, Canada
[8] Humanitas Univ, Milan, Italy
[9] Humanitas Clin Res Inst, Milan, Italy
[10] Northwestern Mem Hosp, Feinberg Sch Med, Chicago, IL 60611 USA
基金
美国国家卫生研究院; 美国医疗保健研究与质量局;
关键词
implantable cardioverter defibrillator; meta-analysis; primary prevention; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; CARDIAC-RESYNCHRONIZATION THERAPY; VENTRICULAR-ARRHYTHMIAS TOVA; CORONARY-ARTERY-DISEASE; NONISCHEMIC CARDIOMYOPATHY; PRIMARY PREVENTION; ISCHEMIC CARDIOMYOPATHY; FOLLOW-UP; DILATED CARDIOMYOPATHY; MYOCARDIAL-INFARCTION;
D O I
10.1111/jce.13307
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: No precise tools exist to predict appropriate shocks in patients with a primary prevention ICD. We sought to identify characteristics predictive of appropriate shocks in patients with a primary prevention implantable cardioverter defibrillator (ICD). Methods: Using patient-level data from the Multicenter Automatic Defibrillator Implantation Trial II (MADIT II) and the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), we identified patients with any appropriate shock. Clinical and demographic variables were included in a logistic regression model to predict appropriate shocks. Results: There were 1,463 patients randomized to an ICD, and 285 (19%) had >= 1 appropriate shock over a median follow-up of 2.59 years. Compared with patients without appropriate ICD shocks, patients who received any appropriate shock tended to have more severe heart failure. In a multiple logistic regression model, predictors of appropriate shocks included NYHA class (NYHA II vs. I: OR 1.65, 95% CI 1.07-2.55; NYHA III vs. I: OR 1.74, 95% CI 1.10-2.76), lower LVEF (per 1% change) (OR 1.04, 95% CI 1.02-1.06), absence of beta-blocker therapy (OR 1.61, 95% CI 1.23-2.12), and single chamber ICD (OR 1.67, 95% CI 1.13-2.45). Conclusion: In this meta-analysis of patient level data from MADIT-II and SCD-HeFT, higher NYHA class, lower LVEF, no beta-blocker therapy, and single chamber ICD (vs. dual chamber) were significant predictors of appropriate shocks.
引用
收藏
页码:1345 / 1351
页数:7
相关论文
共 43 条
[21]   An impaired renal function and advanced heart failure represent independent predictors of the incidence of malignant ventricular arrhythmias in patients with an implantable cardioverter/defibrillator for primary prevention [J].
Kreuz, Jens ;
Balta, Osman ;
Linhart, Markus ;
Fimmers, Rolf ;
Lickfett, Lars ;
Mellert, Fritz ;
Nickenig, Georg ;
Schwab, Joerg Otto .
EUROPACE, 2010, 12 (10) :1439-1445
[22]   Outcomes After Implantable Cardioverter-Defibrillator Generator Replacement for Primary Prevention of Sudden Cardiac Death [J].
Madhavan, Malini ;
Waks, Jonathan W. ;
Friedman, Paul A. ;
Kramer, Daniel B. ;
Buxton, Alfred E. ;
Noseworthy, Peter A. ;
Mehta, Ramila A. ;
Hodge, David O. ;
Higgins, Angela Y. ;
Webster, Tracy L. ;
Witt, Chance M. ;
Cha, Yong-Mei ;
Gersh, Bernard J. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (03)
[23]   Incidence of Defibrillator Shocks After Elective Generator Exchange Following Uneventful First Battery Life [J].
Merchant, Faisal M. ;
Jones, Paul ;
Wehrenberg, Scott ;
Lloyd, Michael S. ;
Saxon, Leslie A. .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2014, 3 (06)
[24]   Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia [J].
Moss, AJ ;
Hall, WJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Klein, H ;
Levine, JH ;
Saksena, S ;
Waldo, AL ;
Wilber, D ;
Brown, MW ;
Heo, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (26) :1933-1940
[25]   Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction [J].
Moss, AJ ;
Zareba, W ;
Hall, WJ ;
Klein, H ;
Wilber, DJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Brown, MW ;
Andrews, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) :877-883
[26]   Reduction in Inappropriate Therapy and Mortality through ICD Programming [J].
Moss, Arthur J. ;
Schuger, Claudio ;
Beck, Christopher A. ;
Brown, Mary W. ;
Cannom, David S. ;
Daubert, James P. ;
Estes, N. A. Mark, III ;
Greenberg, Henry ;
Hall, W. Jackson ;
Huang, David T. ;
Kautzner, Josef ;
Klein, Helmut ;
McNitt, Scott ;
Olshansky, Brian ;
Shoda, Morio ;
Wilber, David ;
Zareba, Wojciech .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 367 (24) :2275-2283
[27]   Persistent atrial fibrillation is associated with appropriate shocks and, heart failure in patients with left ventricular dysfunction treated with an implantable cardioverter defibrillator [J].
Rienstra, Michiel ;
Smit, Marcelle D. ;
Nieuwland, Wybe ;
Tan, Eng S. ;
Wiesfeld, Ans C. P. ;
Anthonio, Rutger L. ;
Van den Berg, Maarten P. ;
Van Veldhuisen, Dirk J. ;
Van Gelder, Isabelle C. .
AMERICAN HEART JOURNAL, 2007, 153 (01) :120-126
[28]   Can we predict which patients with implantable cardioverter defibrillators receive appropriate shock therapy? A study of 155 patients [J].
Rinaldi, CA ;
Simon, RDB ;
Baszko, A ;
Bostock, J ;
Elliot, D ;
Bucknall, C ;
Gill, JS .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 88 (01) :69-75
[29]   Cardiac anxiety after sudden cardiac arrest: Severity, predictors and clinical implications [J].
Rosman, Lindsey ;
Whited, Amanda ;
Lampert, Rachel ;
Mosesso, Vincent N. ;
Lawless, Christine ;
Sears, Samuel F. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 181 :73-76
[30]   Contemporary rates of appropriate shock therapy in patients who receive implantable device therapy in a real-world setting: From the Israeli ICD Registry [J].
Sabbag, Avi ;
Suleiman, Mahmoud ;
Laish-Farkash, Avishag ;
Samania, Nimer ;
Kazatsker, Mark ;
Goldenberg, Ilan ;
Glikson, Michael ;
Beinart, Roy .
HEART RHYTHM, 2015, 12 (12) :2426-2433