Accuracy of potentiometric oxygen sensors with Bi/Bi2O3 reference electrode for use in liquid LBE

被引:62
作者
Lim, J. [1 ]
Marien, A. [1 ]
Rosseel, K. [1 ]
Aerts, A. [1 ]
Van den Bosch, J. [1 ]
机构
[1] Belgian Nucl Res Ctr SCK CEN, B-2400 Mol, Belgium
关键词
LEAD; SOLUBILITY; BI;
D O I
10.1016/j.jnucmat.2012.06.011
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Potentiometric oxygen sensors fabricated with yttria partially stabilized zirconia (YPSZ) and a Bi/Bi2O3 reference electrode were tested in oxygen saturated lead-bismuth eutectic (LBE) and oxygen saturated tin (Sn), respectively, in order to estimate the accuracy of the oxygen sensors prior to applying them to R&D work for MYRRHA. The accuracy of these sensors was estimated in the temperature range of 673-733 K by measuring the electromotive force (emf) of eight sensors. The standard deviation on the measured emf data was about 0.79 mV in the case of oxygen saturated LBE and was about 1.25 mV in the case of oxygen saturated Sn. These values result in a standard deviation of 4% on the oxygen concentration in LBE which is calculated from the measured emf. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:270 / 275
页数:6
相关论文
共 23 条
[1]   MYRRHA: A multipurpose accelerator driven system for research & development [J].
Abderrahim, HA ;
Kupschus, P ;
Malambu, E ;
Benoit, P ;
Van Tichelen, K ;
Arien, B ;
Vermeersch, F ;
D'hondt, P ;
Jongen, Y ;
Ternier, S ;
Vandeplassche, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 463 (03) :487-494
[2]  
Abderrahim HamidAit., 2010, Nuclear Physics News, V20, P24, DOI DOI 10.1080/10506890903178913
[3]   THERMODYNAMICS AND SOLUBILITY OF OXYGEN IN LIQUID METALS FROM EMF MEASUREMENTS INVOLVING SOLID ELECTROLYTES .2. TIN [J].
BELFORD, TN ;
ALCOCK, CB .
TRANSACTIONS OF THE FARADAY SOCIETY, 1965, 61 (507P) :443-&
[4]   Electrochemical oxygen sensors for on-line monitoring in lead-bismuth alloys: status of development [J].
Courouau, JL .
JOURNAL OF NUCLEAR MATERIALS, 2004, 335 (02) :254-259
[5]   Impurities and oxygen control in lead alloys [J].
Courouau, JL ;
Trabuc, P ;
Laplanche, G ;
Deloffre, P ;
Taraud, P ;
Ollivier, M ;
Adriano, R ;
Trambaud, S .
JOURNAL OF NUCLEAR MATERIALS, 2002, 301 (01) :53-59
[6]  
De Bruyn D, 2011, P ICAPP 2011 MAY 2 5
[7]   Development of an oxygen sensor for molten 44.5% lead-55.5% bismuth alloy [J].
Fernández, JA ;
Abellà, J ;
Barceló, J ;
Victori, L .
JOURNAL OF NUCLEAR MATERIALS, 2002, 301 (01) :47-52
[8]   Diffusivity, activity and solubility of oxygen in liquid lead and lead-bismuth eutectic alloy by electrochemical methods [J].
Ganesan, R ;
Gnanasekaran, T ;
Srinivasa, RS .
JOURNAL OF NUCLEAR MATERIALS, 2006, 349 (1-2) :133-149
[9]   Determination of standard molar Gibbs free energy of formation of Bi2O3 over a wide temperature range by EMF method [J].
Ganesan, R ;
Gnanasekaran, T ;
Srinivasa, RS .
JOURNAL OF CHEMICAL THERMODYNAMICS, 2003, 35 (10) :1703-1716
[10]  
Gaskell D.R., 2003, Introduction to the Thermodynamics of Materials, V4th