Removal of Toluene from Polluted Air Using Ozone and Pt Catalyst

被引:0
作者
Baei, Mazyar Sharifzadeh [1 ]
Katal, Reza [2 ]
Abbasian, Saeid [3 ]
机构
[1] Islamic Azad Univ, Ayatollah Amoli Branch, Dept Chem Engn, Amol, Iran
[2] Tarbiat Modares Univ, Fac Chem Engn, Tehran, Iran
[3] Babol Univ Technol, Fac Chem Engn, Babol Sar, Iran
关键词
Polluted air; Ozone; Organic compounds; Catalyst; INDOOR AIR; PHOTOCATALYTIC OXIDATION; ORGANIC-COMPOUNDS; BENZENE; EXPOSURE; QUALITY; VOC; MN;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, removal of volatile organic compounds (VOCs) from polluted air by using ozone based Pt catalyst were investigated. Highly active Pt catalysts for toluene oxidation could be obtained by using colloid-deposition method. The type of the support is an importance of supported Pt/MeOx (Me = Fe, Ni, Zn, Al) catalysts. The results indicated that process of toluene oxidation based on Pt catalyst is dependent on the type of catalyst, temperature and concentration of ozone. As can be seen, in the absence and presence of ozone, Pt/Fe2O3 catalyst has the best efficiency for the removal of toluene in the various temperatures. Furthermore. at 50-200 degrees C, the rate of toluene omission would be higher when the concentration of applied ozone increased.
引用
收藏
页码:81 / 84
页数:4
相关论文
共 23 条
[1]   Removal of pollutants from indoor air using zeolite membranes [J].
Aguado, S ;
Polo, AC ;
Bernal, MP ;
Coronas, J ;
Santamaría, J .
JOURNAL OF MEMBRANE SCIENCE, 2004, 240 (1-2) :159-166
[2]   Influence of support composition on the structure and reactivity of strontium base catalysts [J].
Bordawekar, SV ;
Doskocil, EJ ;
Davis, RJ .
CATALYSIS LETTERS, 1997, 44 (3-4) :193-199
[3]   Catalytic oxidation of benzene with ozone over alumina-supported manganese oxides [J].
Einaga, H ;
Futamura, S .
JOURNAL OF CATALYSIS, 2004, 227 (02) :304-312
[4]   Catalytic oxidation of benzene with ozone over Mn ion-exchanged zeolites [J].
Einaga, Hisahiro ;
Futamura, Shigeru .
CATALYSIS COMMUNICATIONS, 2007, 8 (03) :557-560
[5]   Indoor air quality in the 21st century: Search for excellence [J].
Fanger, PO .
INDOOR AIR, 2000, 10 (02) :68-73
[6]   Evaluation of ionic air purifiers for reducing aerosol exposure in confined indoor spaces [J].
Grinshpun, SA ;
Mainelis, G ;
Trunov, M ;
Adhikari, A ;
Reponen, T ;
Willeke, K .
INDOOR AIR, 2005, 15 (04) :235-245
[7]   Indoor climate in interior Alaska: simultaneous measurement of ventilation, benzene and toluene in residential indoor air of two homes [J].
Isbell, MA ;
Stolzberg, RJ ;
Duffy, LK .
SCIENCE OF THE TOTAL ENVIRONMENT, 2005, 345 (1-3) :31-40
[8]  
JELEN HH, 1995, APPL ENVIRON MICROB, V61, P3815
[9]   Indoor air quality and health [J].
Jones, AP .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (28) :4535-4564
[10]   Asthma and domestic air quality [J].