Biomechanical analysis using Kinovea for sports application

被引:48
作者
Adnan, Nor Muaza Nor [1 ]
Ab Patar, Mohd Nor Azmi [1 ,2 ]
Lee, Hokyoo [2 ]
Yamamoto, Shin-Ichiroh [2 ]
Jong-Young, Lee [3 ]
Mahmud, Jamaluddin [1 ]
机构
[1] Univ Teknol MARA, Fac Mech Engn, Shah Alam 40450, Selangor, Malaysia
[2] Shibaura Inst Technol, Coll Syst Engn & Sci, Minuma Ku, Saitama 3378570, Japan
[3] Suwon Univ, Coll Phys Educ, Hwaseong, Gyunggi Do, South Korea
来源
INTERNATIONAL CONFERENCE ON INNOVATIVE TECHNOLOGY, ENGINEERING AND SCIENCES 2018 (ICITES 2018) | 2018年 / 342卷
关键词
RELIABILITY;
D O I
10.1088/1757-899X/342/1/012097
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper assesses the reliability of HD VideoCam-Kinovea as an alternative tool in conducting motion analysis and measuring knee relative angle of drop jump movement. The motion capture and analysis procedure were conducted in the Biomechanics Lab, Shibaura Institute of Technology, Omiya Campus, Japan. A healthy subject without any gait disorder (BMI of 28.60 +/- 1.40) was recruited. The volunteered subject was asked to per the drop jump movement on preset platform and the motion was simultaneously recorded using an established infrared motion capture system (Hawk-Cortex) and a HD VideoCam in the sagittal plane only. The capture was repeated for 5 times. The outputs (video recordings) from the HD VideoCam were input into Kinovea (an open-source software) and the drop jump pattern was tracked and analysed. These data are compared with the drop jump pattern tracked and analysed earlier using the Hawk-Cortex system. In general, the results obtained (drop jump pattern) using the HD VideoCam-Kinovea are close to the results obtained using the established motion capture system. Basic statistical analyses show that most average variances are less than 10%, thus proving the repeatability of the protocol and the reliability of the results. It can be concluded that the integration of HD VideoCam-Kinovea has the potential to become a reliable motion capture-analysis system. Moreover, it is low cost, portable and easy to use. As a conclusion, the current study and its findings are found useful and has contributed to enhance significant knowledge pertaining to motion capture-analysis, drop jump movement and HD VideoCam-Kinovea integration.
引用
收藏
页数:9
相关论文
共 18 条
[1]   System integration and control of finger orthosis for post stroke rehabilitation [J].
Ab Patar, Mohd Nor Azmi ;
Komeda, Takashi ;
Low, Cheng Yee ;
Mahmud, Jamaluddin .
2ND INTERNATIONAL CONFERENCE ON SYSTEM-INTEGRATED INTELLIGENCE: CHALLENGES FOR PRODUCT AND PRODUCTION ENGINEERING, 2014, 15 :755-764
[2]  
Ab Patar MNA, 2014, 2014 1ST INTERNATIONAL SYMPOSIUM ON TECHNOLOGY MANAGEMENT AND EMERGING TECHNOLOGIES (ISTMET 2014), P82, DOI 10.1109/ISTMET.2014.6936482
[3]  
Amirah N., 2017, Int. Med. Device Technol. Conf, P247
[4]  
Bujang K, 2015, J TEKNOL, V76, P75
[5]  
Damsted C, 2015, INT J SPORTS PHYS TH, V10, P147
[6]  
M. Centre, 2003, CREAT COMM, P2
[7]   An innovative application of a small-scale motion analysis technique to quantify human skin deformation in vivo [J].
Mahmud, Jamaluddin ;
Holt, Cathy A. ;
Evans, Sam L. .
JOURNAL OF BIOMECHANICS, 2010, 43 (05) :1002-1006
[8]  
Motion Analysis, 2010, CORT REF MAN
[9]  
Mustapha G, 2016, INT J GEOMATE, V11, P2248
[10]  
Nielsen D. B., 2008, COMP ANGULAR MEASURE, P26