Fruit Microstructure Evaluation Using Synchrotron X-Ray Computed Tomography

被引:1
|
作者
Verboven, Pieter [1 ]
Ho, Quang Tri [1 ]
Herremans, Els [1 ]
Mebatsion, Hibru Kelemu [1 ]
Nicolai, Bart [1 ]
Kerckhofs, Greet [2 ]
Wevers, Martine [2 ]
Cloetens, Peter [3 ]
机构
[1] Katholieke Univ Leuven, Div BIOSYST MeBioS, W de Croylaan 42,POB 2428, BE-3001 Louvain, Belgium
[2] Katholieke Univ Leuven, Res Grp Mat Performance & Non destructive Evaluat, ID19 High resolution Diffraction Topog Beamlin, BE-3001 Leuven, Belgium
[3] European Synchrotron Radiat Facil, F-38043 Grenoble, France
来源
FOOD ENGINEERING INTERFACES | 2011年
关键词
QUANTITATIVE PHASE TOMOGRAPHY; GAS-EXCHANGE; NETWORK; TISSUE; APPLE; MICROTOMOGRAPHY;
D O I
10.1007/978-1-4419-7475-4_24
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
引用
收藏
页码:589 / +
页数:3
相关论文
共 50 条
  • [1] Determination of Density Distribution of Tablets Using Synchrotron X-ray Computed Tomography
    Takayama, Kozo
    Otoguro, Saori
    Okada, Nobuto
    Hoshino, Masato
    Yagi, Naoto
    Obata, Yasuko
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2017, 137 (06): : 757 - 762
  • [2] Combined X-ray fluorescence and absorption computed tomography using a synchrotron beam
    Hall, C.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [3] Fluorescent x-ray computed tomography with synchrotron radiation using fan collimator
    Takeda, T
    Akiba, M
    Yuasa, T
    Kazama, M
    Hoshino, A
    Watanabe, Y
    Hyodo, K
    Dilmanian, FA
    Akatsuka, T
    Itai, Y
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 685 - 695
  • [4] Quantification of eggshell microstructure using X-ray micro computed tomography
    Riley, A.
    Sturrock, C. J.
    Mooney, S. J.
    Luck, M. R.
    BRITISH POULTRY SCIENCE, 2014, 55 (03) : 311 - 320
  • [5] Progress in Cell Marking for Synchrotron X-ray Computed Tomography
    Hall, Christopher
    Sturm, Erica
    Schultke, Elisabeth
    Arfelli, Fulvia
    Menk, Ralf-Hendrik
    Astolfo, Alberto
    Juurlink, Bernhard H. J.
    6TH INTERNATIONAL CONFERENCE ON MEDICAL APPLICATIONS OF SYNCHROTRON RADIATION, 2010, 1266 : 51 - +
  • [6] Incoherent scatter computed tomography with monochromatic synchrotron x-ray
    Yuasa, T
    Takeda, T
    Akiba, M
    Kazama, M
    Hoshino, A
    Watanabe, Y
    Hyodo, K
    Dilmanian, FA
    Akatsuka, T
    Itai, Y
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 728 - 729
  • [7] Virtual histology uncertainty in synchrotron x-ray micro-computed tomography evaluation
    Lauridsen, T.
    Feidenhans'l, R.
    Pinholt, E. M.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (09) : 1569 - 1575
  • [9] Study on dual-energy X-ray computed tomography using synchrotron radiation
    Tsunoo, T
    Torikoshi, A
    Endo, M
    Natsuhori, A
    Kakizaki, T
    Yamada, N
    Itoh, N
    Uesugi, K
    Yagi, N
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 1368 - 1371
  • [10] Three-dimensional monochromatic x-ray computed tomography using synchrotron radiation
    Saito, T
    Kudo, H
    Takeda, T
    Itai, Y
    Tokumori, K
    Toyofuku, F
    Hyodo, K
    Ando, M
    Nishimura, K
    Uyama, C
    OPTICAL ENGINEERING, 1998, 37 (08) : 2258 - 2268