Effect of plenum chamber obstructions on data center performance

被引:56
作者
Fulpagare, Yogesh [1 ]
Mahamuni, Gaurav [1 ]
Bhargav, Atul [1 ]
机构
[1] Indian Inst Technol Gandhinagar, Energy Syst Lab, Ahmadabad, Gujarat, India
关键词
Data center; Raised floor; CFD; Plenum flow; TILE FLOW DISTRIBUTION; PERFORATED TILES;
D O I
10.1016/j.applthermaleng.2015.01.065
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cool air supplied from a raised floor plenum is the most common cooling technique employed in any electronic data center. Many factors lead to the presence of obstructions in the under-floor plenum chamber. However, detailed investigations on the effect of these obstructions on cooling system performance need to be carried out. We have performed CFD studies to quantify the effect of obstruction and perforated tiles on total CRAC (Computer Room Air Conditioning) flow rates as well as the distribution of flow through CRAC. We investigate various factors affecting the air flow distribution and the corresponding cooling with seven models. This paper describes these models and presents key results, compared with experimental data available from the relevant literature. The flow rates through perforated tiles obtained through simulations show good agreement with the measured values for three CFD models. It was observed that obstructions in the plenum chamber lead to decreased air flow rates by as much as 80%, thereby leading to an increase in the occurrence of hot spots. Further, we demonstrate that pipe placement in the plenum chamber is one of the important factors affecting data center performance and hence there is a need to further develop industry standards. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 18 条
[1]  
Abdelmaksoud W.A., 2010, EXPT COMPUTATIONAL S, P1
[2]  
Bauman FS, 2006, ASHRAE TRAN, V112, P567
[3]  
Bhopte S., 2006, ASME 2006 International Mechanical Engineering Congress and Exposition, P83
[4]   Evaluation of air distribution system's airflow performance for cooling energy savings in high-density data centers [J].
Cho, Jinkyun ;
Yang, Joonyoung ;
Park, Woopyoung .
ENERGY AND BUILDINGS, 2014, 68 :270-279
[5]   Cooling solutions in an operational data centre: A case study [J].
Fakhim, B. ;
Behnia, M. ;
Armfield, S. W. ;
Srinarayana, N. .
APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) :2279-2291
[6]  
Fried E., 1989, FLOW RESISTANCE DESI
[7]   Advances in data center thermal management [J].
Fulpagare, Yogesh ;
Bhargav, Atul .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 43 :981-996
[8]  
Joshi Y, 2012, ENERGY EFFICIENT THERMAL MANAGEMENT OF DATA CENTERS, P1, DOI 10.1007/978-1-4419-7124-1
[9]   Airflow distribution through perforated tiles in raised-floor data centers [J].
Karki, KC ;
Patankar, SV .
BUILDING AND ENVIRONMENT, 2006, 41 (06) :734-744
[10]   Use of computational fluid dynamics for calculating flow rates through perforated tiles in raised-floor data centers [J].
Karki, KC ;
Radmehr, A ;
Patankar, SV .
HVAC&R RESEARCH, 2003, 9 (02) :153-166