Are simple IMRT beams more robust against MLC error? Exploring the impact of MLC errors on planar quality assurance and plan quality for different complexity beams

被引:13
作者
Wang, Jiazhou [1 ]
Jin, Xiance [2 ]
Peng, Jiayuan [1 ]
Xie, Jiang [1 ]
Chen, Junchao [1 ]
Hu, Weigang [1 ,2 ]
机构
[1] Fudan Univ, Shanghai Canc Ctr, Dept Radiat Oncol, 270 Dongan Rd, Shanghai 200433, Peoples R China
[2] Wenzhou Med Coll, Affiliated Hosp 1, Wenzhou, Zhejiang, Peoples R China
关键词
patient QA; planar QA; IMRT; MODULATED ARC THERAPY; PASSING RATES; METRICS; QA; RADIOTHERAPY; DOSIMETRY; ACCURACY; DELIVERY; INDEX;
D O I
10.1120/jacmp.v17i3.6022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study investigated the impact of beam complexities on planar quality assurance and plan quality robustness by introducing MLC errors in intensity-modulate radiation therapy. Forty patients' planar quality assurance QA) plans were enrolled in this study, including 20 dynamic MLC DMLC) IMRT plans and 20 static MLC SMLC) IMRT plans. The total beam numbers were 150 and 160 for DMLC and SMLC, respectively. Six different magnitudes of MLC errors were introduced to these beams. Gamma pass rates were calculated by comparing error-free fluence and error-induced fluence. The plan quality variation was acquired by comparing PTV coverage. Eight complexity scores were calculated based on the beam fluence and the MLC sequence. The complexity scores include fractal dimension, monitor unit, modulation index, fluence map complexity, weighted average of field area, weighted average of field perimeter, and small aperture ratio < 5 cm(2) and < 50 cm(2)). The Spearman's rank correlation coefficient was calculated to analyze the correlation between these scores and gamma pass rate and plan quality variation. For planar QA, the most significant complexity index was fractal dimension for DMLC p = -0.40) and weighted segment area for SMLC p = 0.27) at low magnitude MLC error. For plan quality, the most significant complexity index was weighted segment perimeter for DMLC p = 0.56) and weighted segment area for SMLC p = 0.497) at low magnitude MLC error. The sensitivity of planar QA was weakly associated with the field complexity with low magnitude MLC error, but the plan quality robustness was associated with beam complexity. Plans with simple beams were more robust to MLC error.
引用
收藏
页码:147 / 157
页数:11
相关论文
共 28 条
[1]  
[Anonymous], 2003, APPL STAT BEHAV SCI
[2]   Dosimetric accuracy of tomotherapy dose calculation in thorax lesions [J].
Ardu, Veronica ;
Broggi, Sara ;
Cattaneo, Giovanni Mauro ;
Mangili, Paola ;
Calandrino, Riccardo .
RADIATION ONCOLOGY, 2011, 6
[3]   ROC analysis in patient specific quality assurance [J].
Carlone, Marco ;
Cruje, Charmainne ;
Rangel, Alejandra ;
McCabe, Ryan ;
Nielsen, Michelle ;
MacPherson, Miller .
MEDICAL PHYSICS, 2013, 40 (04)
[4]   Parallel/Opposed: IMRT QA using treatment log files is superior to conventional measurement-based method [J].
Childress, Nathan ;
Chen, Quan ;
Rong, Yi .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01) :4-7
[5]   Treatment plan complexity metrics for predicting IMRT pre-treatment quality assurance results [J].
Crowe, S. B. ;
Kairn, T. ;
Kenny, J. ;
Knight, R. T. ;
Hill, B. ;
Langton, C. M. ;
Trapp, J. V. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (03) :475-482
[6]   Quantification of beam complexity in intensity-modulated radiation therapy treatment plans [J].
Du, Weiliang ;
Cho, Sang Hyun ;
Zhang, Xiaodong ;
Hoffman, Karen E. ;
Kudchadker, Rajat J. .
MEDICAL PHYSICS, 2014, 41 (02)
[7]   IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119 [J].
Ezzell, Gary A. ;
Burmeister, Jay W. ;
Dogan, Nesrin ;
LoSasso, Thomas J. ;
Mechalakos, James G. ;
Mihailidis, Dimitris ;
Molineu, Andrea ;
Palta, Jatinder R. ;
Ramsey, Chester R. ;
Salter, Bill J. ;
Shi, Jie ;
Xia, Ping ;
Yue, Ning J. ;
Xiao, Ying .
MEDICAL PHYSICS, 2009, 36 (11) :5359-5373
[8]   The Radiological Physics Center's standard dataset for small field size output factors [J].
Followill, David S. ;
Kry, Stephen F. ;
Qin, Lihong ;
Leif, Jessica ;
Molineu, Andrea ;
Alvarez, Paola ;
Aguirre, Jose Francisco ;
Ibbott, Geoffrey S. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (05) :282-289
[9]   What is an acceptably smoothed fluence? Dosimetric and delivery considerations for dynamic sliding window IMRT [J].
Giorgia, Nicolini ;
Antonella, Fogliata ;
Eugenio, Vanetti ;
Alessandro, Clivio ;
Filippo, Ammazzalorso ;
Luca, Cozzi .
RADIATION ONCOLOGY, 2007, 2
[10]  
Haidekker M.A., 2011, Advanced biomedical image analysis