A Radiotherapy Planning Study of RapidArc, Intensity Modulated Radiotherapy, Three-Dimensional Conformal Radiotherapy, and Parallel Opposed Beams in the Treatment of Pediatric Retroperitoneal Tumors

被引:14
作者
Shaffer, Richard [1 ,2 ]
Vollans, Emily [3 ]
Vellani, Rosie [3 ]
Welsh, Margaret [3 ]
Moiseenko, Vitali [3 ]
Goddard, Karen [1 ]
机构
[1] British Columbia Canc Agcy, Dept Radiat Oncol, Vancouver, BC V5Z 4E6, Canada
[2] Royal Surrey Cty Hosp, St Lukes Canc Ctr, Guildford, Surrey, England
[3] British Columbia Canc Agcy, Dept Med Phys, Vancouver, BC V5Z 4E6, Canada
关键词
IMRT; neuroblastoma; pediatric; rapidarc; VMAT; CHILDHOOD-CANCER SURVIVOR; RADIATION-THERAPY; ABDOMINAL NEUROBLASTOMA; 2ND CANCERS; IMRT; IMPACT; ARC;
D O I
10.1002/pbc.22649
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background This planning study compared Rapid Arc fixed field IMRT (cIMRT) 3D conformal radiotherapy (3D CRT), and a parallel opposed pair (POP) for children with retroperitoneal tumors Procedure Plans were generated in eight patients to treat the PTV (dose range 19 8-45 Gy) while limiting kidney and liver doses In selected patients vertebral body (VB) dose heterogeneity was minimized Cumulative DVH parameters, monitor units (MU) and treatment times were compared for the four techniques using the Wilcoxon matched pairs test Results RapidArc and cIMRT covered target volumes more conformally than 3D CRT and POP (P=0 012) There was no difference in the ability to meet kidney dose constraints A significantly lower volume of the liver received 12 Gy with cIMRT or RapidArc compared with 3D CRT (P=0 028) Where VB was included in PTV VB dose homogeneity was generally within 94-104% of the prescription dose Time to deliver a single fraction with RapidArc POP, 3D CRT, and cIMRT was 1 25 +/- 0 01, 1 38 +/- 0 10 2 6 +/- 0 45, and 4 02 +/- 1 12 min, respectively (P = 0 012) Monitor units for a single fraction with POP 3D CRT RapidArc, and cIMRT were 203 +/- 26, 235 +/- 32 325 +/- 71 and 665 +/- 215, respectively (P < 0 05) Conclusions POP resulted in favorable MU, treatment time and dosimetry but had poor conformality 3D CRT was more conformal but had higher MU and treatment time RapidArc and cIMRT were generally no better dosimetrically than conformal techniques RapidArc was dosimetrically very similar to cIMRT, but resulted in a major reduction in time and MU used to deliver the radiation Pediatr Blood Cancer 2011 56 16-23 (C) 2010 Wiley Liss Inc
引用
收藏
页码:16 / 23
页数:8
相关论文
共 50 条
[11]   Dosimetric analysis of three-dimensional conformal radiotherapy, intensity-modulated radiotherapy-step and shoot, helical tomotherapy, and volumetric modulated arc therapy in prostate cancer radiotherapy [J].
Gozal, Fenny ;
Gondhowiardjo, Soehartati Argadikoesoema ;
Kodrat, Henry ;
Wibowo, Wahyu Edy .
JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (04) :893-900
[12]   A Model of the Cost-effectiveness of Intensity-modulated Radiotherapy in Comparison with Three-dimensional Conformal Radiotherapy for the Treatment of Localised Prostate Cancer [J].
Hummel, S. R. ;
Stevenson, M. D. ;
Simpson, E. L. ;
Staffurth, J. .
CLINICAL ONCOLOGY, 2012, 24 (10) :E159-E167
[13]   Intensity modulated radiotherapy in early stage Hodgkin lymphoma patients: Is it better than three dimensional conformal radiotherapy? [J].
De Sanctis, Vitaliana ;
Bolzan, Chiara ;
D'Arienzo, Marco ;
Bracci, Stefano ;
Fanelli, Alessandro ;
Cox, Maria Christina ;
Valeriani, Maurizio ;
Osti, Mattia F. ;
Minniti, Giuseppe ;
Chiacchiararelli, Laura ;
Enrici, Riccardo Maurizi .
RADIATION ONCOLOGY, 2012, 7
[14]   Effect of intensity-modulated radiotherapy versus three-dimensional conformal radiotherapy on clinical outcomes in patients with glioblastoma multiforme [J].
Chen Yi-dong ;
Feng Jin ;
Fang Tong ;
Yang Ming ;
Qiu Xiao-guang ;
Jiang Tao .
CHINESE MEDICAL JOURNAL, 2013, 126 (12) :2320-2324
[15]   Comparison of Intensity Modulated Radiotherapy and Dynamic Three-Dimensional Conformal Radiotherapy With Regard to Dose Distribution and Sparing of Organs at Risk [J].
Hasegawa, Yuzo ;
Iuchi, Toshihiko ;
Osato, Katsunobu ;
Kodama, Takashi ;
Toyama, Naoki ;
Hatano, Kazuo .
NEUROLOGIA MEDICO-CHIRURGICA, 2011, 51 (05) :349-355
[16]   Breast size and dose to cardiac substructures in adjuvant three-dimensional conformal radiotherapy compared to tangential intensity modulated radiotherapy [J].
Ratosa, Ivica ;
Jenko, Aljasa ;
Sljivic, Zeljko ;
Pirnat, Maja ;
Oblak, Irena .
RADIOLOGY AND ONCOLOGY, 2020, 54 (04) :470-479
[17]   Dosimetric aspects of breast radiotherapy with three-dimensional and intensity-modulated radiotherapy helical tomotherapy planning modules [J].
Yadav, Poonam ;
Yan, Yue ;
Ignatowski, Tasha ;
Olson, Anna .
MEDICAL DOSIMETRY, 2017, 42 (01) :42-46
[18]   Dosimetric comparison between intensity modulated radiotherapy and three dimensional conformal radiotherapy planning in patients with locally advanced cervical carcinoma [J].
Naik, A. ;
Gurjar, O. P. ;
Bagdare, P. ;
Gupta, K. L. ;
Bhandari, V. ;
Kausar, M. ;
Ladia, D. D. ;
Mittal, H. K. .
INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (03) :189-196
[19]   Three-dimensional conformal versus intensity modulated radiotherapy in breast cancer treatment: is necessary a medical reversal? [J].
Fiorentino, Alba ;
Ruggieri, Ruggero ;
Giaj-Levra, Niccolo ;
Sicignano, Gianluisa ;
Di Paola, Gioacchino ;
Naccarato, Stefania ;
Fersino, Sergio ;
Mazzola, Rosario ;
Tebano, Umberto ;
Ricchetti, Francesco ;
Alongi, Filippo .
RADIOLOGIA MEDICA, 2017, 122 (02) :146-153
[20]   A comparison of clinical outcomes between three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for prostate cancer [J].
Takuya Shimizuguchi ;
Keiji Nihei ;
Tomoyuki Okano ;
Yumiko Machitori ;
Kei Ito ;
Katsuyuki Karasawa .
International Journal of Clinical Oncology, 2017, 22 :373-379