A Radiotherapy Planning Study of RapidArc, Intensity Modulated Radiotherapy, Three-Dimensional Conformal Radiotherapy, and Parallel Opposed Beams in the Treatment of Pediatric Retroperitoneal Tumors

被引:14
|
作者
Shaffer, Richard [1 ,2 ]
Vollans, Emily [3 ]
Vellani, Rosie [3 ]
Welsh, Margaret [3 ]
Moiseenko, Vitali [3 ]
Goddard, Karen [1 ]
机构
[1] British Columbia Canc Agcy, Dept Radiat Oncol, Vancouver, BC V5Z 4E6, Canada
[2] Royal Surrey Cty Hosp, St Lukes Canc Ctr, Guildford, Surrey, England
[3] British Columbia Canc Agcy, Dept Med Phys, Vancouver, BC V5Z 4E6, Canada
关键词
IMRT; neuroblastoma; pediatric; rapidarc; VMAT; CHILDHOOD-CANCER SURVIVOR; RADIATION-THERAPY; ABDOMINAL NEUROBLASTOMA; 2ND CANCERS; IMRT; IMPACT; ARC;
D O I
10.1002/pbc.22649
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background This planning study compared Rapid Arc fixed field IMRT (cIMRT) 3D conformal radiotherapy (3D CRT), and a parallel opposed pair (POP) for children with retroperitoneal tumors Procedure Plans were generated in eight patients to treat the PTV (dose range 19 8-45 Gy) while limiting kidney and liver doses In selected patients vertebral body (VB) dose heterogeneity was minimized Cumulative DVH parameters, monitor units (MU) and treatment times were compared for the four techniques using the Wilcoxon matched pairs test Results RapidArc and cIMRT covered target volumes more conformally than 3D CRT and POP (P=0 012) There was no difference in the ability to meet kidney dose constraints A significantly lower volume of the liver received 12 Gy with cIMRT or RapidArc compared with 3D CRT (P=0 028) Where VB was included in PTV VB dose homogeneity was generally within 94-104% of the prescription dose Time to deliver a single fraction with RapidArc POP, 3D CRT, and cIMRT was 1 25 +/- 0 01, 1 38 +/- 0 10 2 6 +/- 0 45, and 4 02 +/- 1 12 min, respectively (P = 0 012) Monitor units for a single fraction with POP 3D CRT RapidArc, and cIMRT were 203 +/- 26, 235 +/- 32 325 +/- 71 and 665 +/- 215, respectively (P < 0 05) Conclusions POP resulted in favorable MU, treatment time and dosimetry but had poor conformality 3D CRT was more conformal but had higher MU and treatment time RapidArc and cIMRT were generally no better dosimetrically than conformal techniques RapidArc was dosimetrically very similar to cIMRT, but resulted in a major reduction in time and MU used to deliver the radiation Pediatr Blood Cancer 2011 56 16-23 (C) 2010 Wiley Liss Inc
引用
收藏
页码:16 / 23
页数:8
相关论文
共 50 条
  • [1] A RADIOTHERAPY PLANNING STUDY OF RAPIDARC, INTENSITY MODULATED RADIOTHERAPY AND THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY IN THE TREATMENT OF PEDIATRIC RETROPERITONEAL TUMORS
    Shaffer, R.
    Vollans, E.
    Vellani, R.
    Welsh, M.
    Moiseenko, V.
    Goddard, K.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S370 - S370
  • [2] A Comparison of Three-dimensional Conformal Proton Radiotherapy, Three-Dimensional Conformal Photon Radiotherapy and Intensity Modulated Radiotherapy for Retroperitoneal Sarcomas
    Swanson, E. L.
    Slopsema, R.
    Louis, D.
    Paryani, N.
    Morris, C. G.
    Indelicato, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S612 - S612
  • [3] Intensity-modulated three-dimensional conformal radiotherapy
    Mohan, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 121 - 121
  • [4] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    Thibouw, David
    Truc, Gilles
    Bertaut, Aurelie
    Chevalier, Cedric
    Aubignac, Leone
    Mirjolet, Celine
    JOURNAL OF NEURO-ONCOLOGY, 2018, 137 (02) : 429 - 438
  • [5] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    David Thibouw
    Gilles Truc
    Aurélie Bertaut
    Cédric Chevalier
    Léone Aubignac
    Céline Mirjolet
    Journal of Neuro-Oncology, 2018, 137 : 429 - 438
  • [6] Superiority of intensity modulated radiotherapy over best three-dimensional conformal radiotherapy combined with brachytherapy in treatment of nasopharyngeal carcinoma: A planning study
    Taheri-Kadkhoda, Z.
    Pettersson, N.
    Johansson, K-A.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S380 - S381
  • [7] Dosimetric Evaluation of Intensity Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy Treatment Plans for Prostate Cancer
    Adeneye, Samuel
    Akpochafor, Michael
    Habeebu, Muhammad
    Omojola, Akintayo
    Joseph, Adedayo
    Awhariado, John
    Durosinnmi-Etti, Abayomi
    Aweda, Moses
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2021, 36 (01): : 104 - 111
  • [8] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy for Paediatric Neuroblastoma
    Jiang, M.
    PEDIATRIC BLOOD & CANCER, 2016, 63 : S196 - S196
  • [9] DOSIMETRIC COMPARISON OF THREE-DIMENSIONAL CONFORMAL PROTON RADIOTHERAPY, INTENSITY-MODULATED PROTON THERAPY, AND INTENSITY-MODULATED RADIOTHERAPY FOR TREATMENT OF PEDIATRIC CRANIOPHARYNGIOMAS
    Boehling, Nicholas S.
    Grosshans, David R.
    Bluett, Jaques B.
    Palmer, Matthew T.
    Song, Xiaofei
    Amos, Richard A.
    Sahoo, Narayan
    Meyer, Jeffrey J.
    Mahajan, Anita
    Woo, Shiao Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (02): : 643 - 652
  • [10] Superiority of intensity-modulated radiotherapy over three-dimensional conformal radiotherapy combined with brachytherapy in nasopharyngeal carcinoma:: a planning study
    Taheri-Kadkhoda, Z.
    Pettersson, N.
    Bjoerk-Eriksson, T.
    Johansson, K-A
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (965): : 397 - 405