Novel flow analysis of regenerator under oscillating flow with pulsating pressure

被引:42
作者
Nam, K [1 ]
Jeong, S [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Mech Engn, Cryogen Engn Lab, Taejon 305701, South Korea
关键词
friction factor; oscillating flow; phase angle; volume-averaging; regenerator; cryocooler;
D O I
10.1016/j.cryogenics.2005.01.001
中图分类号
O414.1 [热力学];
学科分类号
摘要
A new model for the oscillating flow combined with pulsating pressure in cryocooler regenerators is developed to overcome inaccuracy of the conventional flow model based on steady flow friction factor. The new model is based on two non-dimensional parameters and one-dimensional governing equations. One of the parameters is the oscillating flow friction factor represented by the amplitudes of the pressure drop and the flow rate. The idea of the other important parameter originates from a volume averaged continuity equation, which includes the characteristic of randomly oriented matrix geometry. This parameter is named as Breathing factor, which implies that the regenerator breathes against the main oscillating flow. Empirical correlations of the parameters are obtained for screen regenerators. It is revealed that the phase angles of the pressure drop and the mass flow rate in regenerators are well predicted by introduction of the Breathing factor. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:368 / 379
页数:12
相关论文
共 19 条
[1]  
ACKERMANN RA, 1997, CRYOGENIC REGENERATI
[2]  
[Anonymous], 17 INT EN CONV ENG C
[3]   Investigation on the pressure drop characteristics of cryocooler regenerators under oscillating flow and pulsating pressure conditions [J].
Choi, SR ;
Nam, KW ;
Jeong, SK .
CRYOGENICS, 2004, 44 (03) :203-210
[4]  
GARY J, 2001, REGEN3 2 USER MANUAL
[5]   GENERAL EQUATIONS FOR FLOW IN POROUS-MEDIA AND THEIR REDUCTION TO DARCYS LAW [J].
GRAY, WG ;
ONEILL, K .
WATER RESOURCES RESEARCH, 1976, 12 (02) :148-154
[6]  
HARPOLE GM, 1990, P 6 INT CRY C PLYM M, P91
[7]  
Helvensteijn BPM, 1998, ADV CRYOG ENG, V43, P1619
[8]   On pressure-velocity correlation of steady and oscillating flows in regenerators made of wire screens [J].
Hsu, CT ;
Fu, HL ;
Cheng, P .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (01) :52-56
[9]   Experimental study of the oscillating flow characteristics for a regenerator in a pulse tube cryocooler [J].
Ju, YL ;
Jiang, Y ;
Zhou, Y .
CRYOGENICS, 1998, 38 (06) :649-656
[10]  
Kaviany M., 1995, MECH ENG SERIES