Groundwater Mound due to Artificial Recharge from Rectangular Areas

被引:10
|
作者
Singh, Sushil K. [1 ]
机构
[1] Natl Inst Hydrol, Roorkee 247667, Uttar Pradesh, India
关键词
Groundwater; Artificial recharge; Groundwater mound; Unsteady flow; Transient recharge; Analytical solution; Percolation basin; Spreading basin; Kernel method; GROWTH; STREAM; DECAY; STAGE;
D O I
10.1061/(ASCE)IR.1943-4774.0000427
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
The suitability of the widely used existing solution for calculating groundwater mound due to artificial recharge from rectangular areas is examined for its applicability to unconfined aquifers, and this solution has been found applicable only to confined aquifers. The solution applicable for confined aquifers is derived and shown equivalent to the existing solutions. A computationally simple function is proposed for accurately approximating the integral appearing in this or existing solutions. A procedure involving analytical approximation is outlined for using this solution for unconfined aquifers. A method to calculate groundwater mound height in unconfined aquifers due to arbitrarily varying temporal recharge (percolation) is also proposed. It is hoped that the proposed methods would be of help to field engineers and practitioners.
引用
收藏
页码:476 / 480
页数:5
相关论文
共 50 条
  • [31] Perspectives of artificial recharge of groundwater in southern European Russia
    Zektser, I. S.
    Potapova, E. Yu.
    Chetverikova, A. V.
    Shtengelov, R. S.
    WATER RESOURCES, 2012, 39 (06) : 672 - 684
  • [32] Effectiveness of check dam and percolation pond with percolation wells for artificial groundwater recharge using groundwater models
    Abraham, Marykutty
    Mohan, S.
    WATER SUPPLY, 2019, 19 (07) : 2107 - 2115
  • [33] Impact of artificial recharge on groundwater recharge estimated by groundwater modeling (case study: Jarmeh flood spreading, Iran)
    Chitsazan, M.
    Nozarpour, L.
    Movahedian, A.
    SUSTAINABLE WATER RESOURCES MANAGEMENT, 2018, 4 (01) : 79 - 89
  • [34] Evaluation of areas for artificial groundwater recharge in Ayyar basin, Tamil Nadu, India through statistical terrain analysis
    Anbazhagan, S.
    Ramasamy, S. M.
    JOURNAL OF THE GEOLOGICAL SOCIETY OF INDIA, 2006, 67 (01) : 59 - 68
  • [35] Analytical Model of Groundwater Flow in a Rectangular Domain for Spatiotemporally Distributed Recharge
    Hsieh, Ping-Cheng
    Yu, Po-Wen
    Wu, Ming-Chang
    HYDROLOGICAL PROCESSES, 2025, 39 (03)
  • [36] Investigation of introducing water from an artificial recharge plant to an existing groundwater distribution system
    Berg, RL
    Jensen, TO
    Bennedsen, L
    Brandt, G
    4th World Water Congress: Innovation in Water Supply - Reuse and Efficiency, 2005, 5 (01): : 25 - 32
  • [37] Two-Dimensional Modelling of Water Table Fluctuations due to Time-Varying Recharge from Rectangular Basin
    A. Manglik
    S. N. Rai
    Water Resources Management, 1998, 12 : 467 - 475
  • [38] Numerical modelling of physical clogging during groundwater artificial recharge
    Lu, Ying
    Du, X. Q.
    Chi, B. M.
    Yang, Y. S.
    Fan, W.
    CALIBRATION AND RELIABILITY IN GROUNDWATER MODELLING: MANAGING GROUNDWATER AND THE ENVIRONMENT, 2011, 341 : 121 - 126
  • [39] Efficiency of Artificial Groundwater Recharge, Quantification Through Conceptual Modelling
    Mounira Zammouri
    Naima Brini
    Water Resources Management, 2020, 34 : 3345 - 3361
  • [40] Two-Dimensional Modelling of Water Table Fluctuations due to Time-Varying Recharge from Rectangular Basin
    Manglik, A.
    Rai, S. N.
    WATER RESOURCES MANAGEMENT, 1998, 12 (06) : 467 - 475