Effects of systematic partial volume errors on the estimation of gray matter cerebral blood flow with arterial spin labeling MRI

被引:27
作者
Petr, Jan [1 ,2 ]
Mutsaerts, Henri J. M. M. [2 ,3 ,4 ,5 ]
De Vita, Enrico [6 ,7 ]
Steketee, Rebecca M. E. [8 ]
Smits, Marion [8 ]
Nederveen, Aart J. [4 ]
Hofheinz, Frank [1 ]
van den Hoff, Joerg [1 ,9 ]
Asllani, Iris [2 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, Inst Radiopharmaceut Canc Res, Dresden, Germany
[2] Rochester Inst Technol, Dept Biomed Engn, Rochester, NY 14623 USA
[3] Sunnybrook Res Inst, Toronto, ON, Canada
[4] Acad Med Ctr Amsterdam, Dept Radiol, Amsterdam, Netherlands
[5] Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[6] Natl Hosp Neurol & Neurosurg, Lysholm Dept Neuroradiol, London, England
[7] Kings Coll London, Sch Biomed Engn & Imaging Sci, St Thomas Hosp, Dept Biomed Engn,Kings Hlth Partners, London, England
[8] Erasmus MC Univ Med Ctr Rotterdam, Dept Radiol & Nucl Med, Rotterdam, Netherlands
[9] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Dept Nucl Med, Dresden, Germany
关键词
Arterial spin labeling; Perfusion magnetic resonance imaging; Cerebral blood flow; Partial volume; POSITRON-EMISSION-TOMOGRAPHY; CLINICAL-APPLICATIONS; PERFUSION; BRAIN; INVERSION; DEMENTIA; IMAGES; MULTICENTER; ALGORITHM; SEQUENCE;
D O I
10.1007/s10334-018-0691-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivePartial volume (PV) correction is an important step in arterial spin labeling (ASL) MRI that is used to separate perfusion from structural effects when computing the mean gray matter (GM) perfusion. There are three main methods for performing this correction: (1) GM-threshold, which includes only voxels with GM volume above a preset threshold; (2) GM-weighted, which uses voxel-wise GM contribution combined with thresholding; and (3) PVC, which applies a spatial linear regression algorithm to estimate the flow contribution of each tissue at a given voxel. In all cases, GM volume is obtained using PV maps extracted from the segmentation of the T1-weighted (T1w) image. As such, PV maps contain errors due to the difference in readout type and spatial resolution between ASL and T1w images. Here, we estimated these errors and evaluated their effect on the performance of each PV correction method in computing GM cerebral blood flow (CBF).Materials and methodsTwenty-two volunteers underwent scanning using 2D echo planar imaging (EPI) and 3D spiral ASL. For each PV correction method, GM CBF was computed using PV maps simulated to contain estimated errors due to spatial resolution mismatch and geometric distortions which are caused by the mismatch in readout between ASL and T1w images. Results were analyzed to assess the effect of each error on the estimation of GM CBF from ASL data.ResultsGeometric distortion had the largest effect on the 2D EPI data, whereas the 3D spiral was most affected by the resolution mismatch. The PVC method outperformed the GM-threshold even in the presence of combined errors from resolution mismatch and geometric distortions. The quantitative advantage of PVC was 16% without and 10% with the combined errors for both 2D and 3D ASL. Consistent with theoretical expectations, for error-free PV maps, the PVC method extracted the true GM CBF. In contrast, GM-weighted overestimated GM CBF by 5%, while GM-threshold underestimated it by 16%. The presence of PV map errors decreased the calculated GM CBF for all methods.ConclusionThe quality of PV maps presents no argument for the preferential use of the GM-threshold method over PVC in the clinical application of ASL.
引用
收藏
页码:725 / 734
页数:10
相关论文
共 37 条
[1]   Partial volume correction of brain perfusion estimates using the inherent signal data of time-resolved arterial spin labeling [J].
Ahlgren, Andre ;
Wirestam, Ronnie ;
Petersen, Esben Thade ;
Stahlberg, Freddy ;
Knutsson, Linda .
NMR IN BIOMEDICINE, 2014, 27 (09) :1112-1122
[2]   Recommended Implementation of Arterial Spin-Labeled Perfusion MRI for Clinical Applications: A Consensus of the ISMRM Perfusion Study Group and the European Consortium for ASL in Dementia [J].
Alsop, David C. ;
Detre, John A. ;
Golay, Xavier ;
Guenther, Matthias ;
Hendrikse, Jeroen ;
Hernandez-Garcia, Luis ;
Lu, Hanzhang ;
MacIntosh, Bradley J. ;
Parkes, Laura M. ;
Smits, Marion ;
van Osch, Matthias J. P. ;
Wang, Danny J. J. ;
Wong, Eric C. ;
Zaharchuk, Greg .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) :102-116
[3]   How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging [J].
Andersson, JLR ;
Skare, S ;
Ashburner, J .
NEUROIMAGE, 2003, 20 (02) :870-888
[4]  
Ashburner J, 1999, HUM BRAIN MAPP, V7, P254, DOI 10.1002/(SICI)1097-0193(1999)7:4<254::AID-HBM4>3.0.CO
[5]  
2-G
[6]   A fast diffeomorphic image registration algorithm [J].
Ashburner, John .
NEUROIMAGE, 2007, 38 (01) :95-113
[7]   Separating Function From Structure in Perfusion Imaging of the Aging Brain [J].
Asllani, Iris ;
Habeck, Christian ;
Borogovac, Ajna ;
Brown, Truman R. ;
Brickman, Adam M. ;
Stern, Yaakov .
HUMAN BRAIN MAPPING, 2009, 30 (09) :2927-2935
[8]   Regression Algorithm Correcting for Partial Volume Effects in Arterial Spin Labeling MRI [J].
Asllani, Iris ;
Borogovac, Ajna ;
Brown, Truman R. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) :1362-1371
[9]   Positron emission tomography partial volume correction: Estimation and algorithms [J].
Aston, JAD ;
Cunningham, VJ ;
Asselin, MC ;
Hammers, A ;
Evans, AC ;
Gunn, RN .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2002, 22 (08) :1019-1034
[10]  
BoscoloGalazzo I, 2014, P 22 JOINT ANN M ISM, P2704