Automated visibility map of the internal colon surface from colonoscopy video

被引:15
作者
Armin, Mohammad Ali [1 ,2 ]
Chetty, Girija [1 ]
De Visser, Hans [2 ]
Dumas, Cedric [2 ]
Grimpen, Florian [3 ]
Salvado, Olivier [2 ]
机构
[1] Univ Canberra, HCT, Canberra, ACT, Australia
[2] UQ Hlth Sci, Australian E Hlth Res Ctr, CSIRO Biomed Informat, Level 5, Brisbane, Qld 4029, Australia
[3] Royal Brisbane & Womens Hosp, Dept Gastroenterol & Hepatol, Brisbane, Qld, Australia
关键词
Colonoscopy quality; Camera motion parameters; Camera motion drift; Optical colonoscopy; Uncovered area; Visibility map; REGISTRATION; TRACKING; QUALITY; REAL;
D O I
10.1007/s11548-016-1462-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Optical colonoscopy is a prominent procedure by which clinicians examine the surface of the colon for cancerous polyps using a flexible colonoscope. One of the main concerns regarding the quality of the colonoscopy is to ensure that the whole colonic surface has been inspected for abnormalities. In this paper, we aim at estimating areas that have not been covered thoroughly by providing a map from the internal colon surface. Camera parameters were estimated using optical flow between consecutive colonoscopy frames. A cylinder model was fitted to the colon structure using 3D pseudo stereo vision and projected into each frame. A circumferential band from the cylinder was extracted to unroll the internal colon surface (band image). By registering these band images, drift in estimating camera motion could be reduced, and a visibility map of the colon surface could be generated, revealing uncovered areas by the colonoscope. Hidden areas behind haustral folds were ignored in this study. The method was validated on simulated and actual colonoscopy videos. The realistic simulated videos were generated using a colonoscopy simulator with known ground truth, and the actual colonoscopy videos were manually assessed by a clinical expert. The proposed method obtained a sensitivity and precision of 98 and 96 % for detecting the number of uncovered areas on simulated data, whereas validation on real videos showed a sensitivity and precision of 96 and 78 %, respectively. Error in camera motion drift could be reduced by almost 50 % using results from band image registration. Using a simple cylindrical model for the colon and reducing drift by registering band images allows for the generation of visibility maps. The current results also suggest that the provided feedback through the visibility map could enhance clinicians' awareness of uncovered areas, which in return could reduce the probability of missing polyps.
引用
收藏
页码:1599 / 1610
页数:12
相关论文
共 41 条
[1]  
Armin Mohammad Ali, 2016, Computer-Assisted and Robotic Endoscopy. Second International Workshop, CARE 2015 Held in Conjunction with MICCAI 2015, P153, DOI 10.1007/978-3-319-29965-5_15
[2]   Visibility Map: A New Method in Evaluation Quality of Optical Colonoscopy [J].
Armin, Mohammad Ali ;
De Visser, Hans ;
Chetty, Girija ;
Dumas, Cedric ;
Conlan, David ;
Grimpen, Florian ;
Salvado, Olivier .
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT I, 2015, 9349 :396-404
[3]  
Bao G, 2013, VIDEO AIDED RF LOCAL
[4]   Hybrid Localization of Microrobotic Endoscopic Capsule Inside Small Intestine by Data Fusion of Vision and RF Sensors [J].
Bao, Guanqun ;
Pahlavan, Kaveh ;
Mi, Liang .
IEEE SENSORS JOURNAL, 2015, 15 (05) :2669-2678
[5]   Colonoscopic withdrawal times and adenoma detection during screening colonoscopy [J].
Barclay, Robert L. ;
Vicari, Joseph J. ;
Doughty, Andrea S. ;
Johanson, John F. ;
Greenlaw, Roger L. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (24) :2533-2541
[6]   Speeded-Up Robust Features (SURF) [J].
Bay, Herbert ;
Ess, Andreas ;
Tuytelaars, Tinne ;
Van Gool, Luc .
COMPUTER VISION AND IMAGE UNDERSTANDING, 2008, 110 (03) :346-359
[7]   Stitching and Surface Reconstruction From Endoscopic Image Sequences: A Review of Applications and Methods [J].
Bergen, Tobias ;
Wittenberg, Thomas .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (01) :304-321
[8]  
Cotton PB, 2008, PRACTICAL GASTROINTE, P81, DOI [10.1002/9780470987032.ch6, DOI 10.1002/9780470987032.CH6]
[9]  
de Groen Piet C, 2010, Gastrointest Endosc Clin N Am, V20, P699, DOI 10.1016/j.giec.2010.07.012
[10]   DEVELOPING A NEXT GENERATION COLONOSCOPY SIMULATOR [J].
De Visser, Hans ;
Passenger, Josh ;
Conlan, David ;
Russ, Christoph ;
Hellier, David ;
Cheng, Mario ;
Acosta, Oscar ;
Ourselin, Sebastien ;
Salvado, Olivier .
INTERNATIONAL JOURNAL OF IMAGE AND GRAPHICS, 2010, 10 (02) :203-217