Molecular scale track structure simulations in liquid water using the Geant4-DNA Monte-Carlo processes

被引:68
作者
Francis, Z. [1 ]
Incerti, S. [2 ]
Capra, R.
Mascialino, B. [3 ]
Montarou, G. [4 ]
Stepan, V. [5 ]
Villagrasa, C. [1 ]
机构
[1] Inst Radioprotect & Surete Nucl, Lab Dosimetrie Rayonnements Ionisants, F-92262 Fontenay Aux Roses, France
[2] Univ Bordeaux 1, CNRS, IN2P3, CENBG, F-33175 Gradignan, France
[3] Stockholm Univ, Dept Med Radiat Phys, S-17176 Stockholm, Sweden
[4] Phys Corpusculaire Lab, F-63177 Aubiere, France
[5] Acad Sci Czech Republ, Inst Nucl Phys, Prague 8, Czech Republic
关键词
Monte Carlo; Geant4; DNA; Microdosimetry; Cross sections; INELASTIC CROSS-SECTIONS; LOW-ENERGY ELECTRONS; DIELECTRIC RESPONSE MODEL; RADIATION BIOLOGY; PROTON COLLISIONS; SCATTERING; DISTRIBUTIONS; TRANSPORT; SYSTEMS; DNA;
D O I
10.1016/j.apradiso.2010.08.011
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This paper presents a study of energy deposits induced by ionising particles in liquid water at the molecular scale Particles track structures were generated using the Geant4-DNA processes of the Geant4 Monte-Carlo toolkit These processes cover electrons (0 025 eV-1 MeV) protons (1 keV-100 MeV) hydrogen atoms (1 keV-100 MeV) and alpha particles (10 keV-40 MeV) including their different charge states Electron ranges and lineal energies for protons were calculated in nanometric and micrometric volumes (C) 2010 Elsevier Ltd All rights reserved
引用
收藏
页码:220 / 226
页数:7
相关论文
共 61 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Geant4 developments and applications [J].
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Dubois, PA ;
Asai, M ;
Barrand, G ;
Capra, R ;
Chauvie, S ;
Chytracek, R ;
Cirrone, GAP ;
Cooperman, G ;
Cosmo, G ;
Cuttone, G ;
Daquino, GG ;
Donszelmann, M ;
Dressel, M ;
Folger, G ;
Foppiano, F ;
Generowicz, J ;
Grichine, V ;
Guatelli, S ;
Gumplinger, P ;
Heikkinen, A ;
Hrivnacova, I ;
Howard, A ;
Incerti, S ;
Ivanchenko, V ;
Johnson, T ;
Jones, F ;
Koi, T ;
Kokoulin, R ;
Kossov, M ;
Kurashige, H ;
Lara, V ;
Larsson, S ;
Lei, F ;
Link, O ;
Longo, F ;
Maire, M ;
Mantero, A ;
Mascialino, B ;
McLaren, I ;
Lorenzo, PM ;
Minamimoto, K ;
Murakami, K ;
Nieminen, P ;
Pandola, L ;
Parlati, S ;
Peralta, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :270-278
[3]  
[Anonymous], 1993, STOPPING POWERS RANG
[4]   Electron and positron elastic scattering in gaseous and liquid water: A comparative study [J].
Aouchiche, H. ;
Champion, C. ;
Oubaziz, D. .
RADIATION PHYSICS AND CHEMISTRY, 2008, 77 (02) :107-114
[5]   THE PHOTOELECTRON-SPECTRUM OF WATER IN THE 30-140 EV PHOTON ENERGY-RANGE [J].
BANNA, MS ;
MCQUAIDE, BH ;
MALUTZKI, R ;
SCHMIDT, V .
JOURNAL OF CHEMICAL PHYSICS, 1986, 84 (09) :4739-4744
[6]   CROSS-SECTIONS FOR ELECTRON CAPTURE BY 0.3- TO 70-KEV DEUTERONS IN H2, H2O, CO, CH4 AND C8F16 GASES [J].
BERKNER, KH ;
PYLE, RV ;
STEARNS, JW .
NUCLEAR FUSION, 1970, 10 (02) :145-&
[7]  
Bethe H, 1930, ANN PHYS-BERLIN, V5, P325
[8]  
Bethe H., 1933, HDB PHYS, V24/1
[9]   Charged particle tracks in water of different phases. Monte Carlo simulation of electron tracks [J].
Bigildeev, EA ;
Michalik, V .
RADIATION PHYSICS AND CHEMISTRY, 1996, 47 (02) :197-207
[10]   Comparisons of LET distributions for protons with energies between 50 and 200 MeV determined using a spherical tissue-equivalent proportional counter (TEPC) and a position-sensitive silicon spectrometer (RRMD-III) [J].
Borak, TB ;
Doke, T ;
Fuse, T ;
Guetersloh, S ;
Heilbronn, L ;
Hara, K ;
Moyers, M ;
Suzuki, S ;
Taddei, P ;
Terasawa, K ;
Zeitlin, CJ .
RADIATION RESEARCH, 2004, 162 (06) :687-692