Outcomes of Endurant stent graft in narrow aortic bifurcation

被引:19
作者
Troisi, Nicola [1 ]
Donas, Konstantinos P. [2 ,3 ]
Weiss, Kristin [2 ,3 ]
Michelagnoli, Stefano [1 ]
Torsello, Giovanni [2 ,3 ]
Bisdas, Theodosios [2 ,3 ]
机构
[1] San Giovanni Dio Hosp, Dept Surg, Vasc & Endovasc Surg Unit, Via Torregalli 3, I-50143 Florence, Italy
[2] St Franziskus Hosp, Dept Vasc Surg, Munster, Germany
[3] Univ Hosp, Ctr Vasc & Endovasc Surg, Munster, Germany
关键词
ENDOVASCULAR AAA REPAIR; OFF-LABEL CONDITIONS; ANEURYSM REPAIR; DISTAL AORTA; LIMB OCCLUSION; SYSTEM; INSTRUCTIONS; GENERATION; EXPERIENCE; DEVICE;
D O I
10.1016/j.jvs.2015.11.053
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The purpose of this study was to compare the outcomes obtained with Endurant stent graft in the early and midterm period in the treatment of patients with narrow aortic bifurcation vs patients with standard aortic bifurcation. Methods: Data were prospectively collected from 817 patients with abdominal aortic aneurysm treated between November 2007 and August 2014 with the Endurant stent graft at our center. There were 87 patients (10.6%) with a narrow aortic bifurcation (<= 20 mm; NA group). The remaining 730 patients (89.4%) had a standard aortic bifurcation (SA group). Early and estimated 3-year outcomes were evaluated in these patients in terms of survival, freedom from any device-related reinterventions, and freedom from graft thrombosis. Univariate and multivariate analyses in the NA group were performed to detect possible predictors for poor outcomes. Results: The two groups were similar in terms of demographics, preoperative diagnostic assessment, and intraoperative data. In 211 of 817 patients (25.8%), an adjunctive iliac limb stenting by balloon-expanding stents was performed. Overall, 41 patients in the NA group (47.1%) underwent iliac limb stenting, whereas an iliac stent was implanted in just 170 patients (23.3%) in the SA group (P < .001). The mean follow-up was 16.3 months (range, 1-73 months). The estimated 3-year survival rate was similar between the two groups (87.2% in the NA group vs 80.8% in the SA group; P = [.84). Furthermore, the estimated freedom from any device-related reinterventions was 92.9% in the NA group and 85.5% in the SA group (P = .1). Finally, the estimated 3-year freedom from graft thrombosis was 96.9% in the NA group and 94.8% in the SA group (P = .79). In the NA group at univariate and multivariate analyses, none of the examined preoperative or intraoperative factors were independent predictors of poor outcomes. Conclusions: Use of bifurcated Endurant stent graft, combined in almost half of the patients with narrow aortic bifurcation with additional aortoiliac stent placement, is feasible and safe. Early and midterm outcomes are similar to those obtained in non-narrow aortic bifurcation.
引用
收藏
页码:1135 / 1140
页数:6
相关论文
共 25 条
[1]   Outcomes of a novel technique of endovascular repair of aneurysmal internal iliac arteries using iliac branch devices [J].
Austermann, Martin ;
Bisdas, Theodosios ;
Torsello, Giovanni ;
Bosiers, Michel J. ;
Lazaridis, Konstantinos ;
Donas, Konstantinos P. .
JOURNAL OF VASCULAR SURGERY, 2013, 58 (05) :1186-1191
[2]   Severe Proximal Aneurysm Neck Angulation: Early Results Using the Endurant Stentgraft System [J].
Bastos Goncalves, F. ;
de Vries, J. -P. P. M. ;
van Keulen, J. W. ;
Dekker, H. ;
Moll, F. L. ;
van Herwaarden, J. A. ;
Verhagen, H. J. M. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 41 (02) :193-200
[3]   Durability of the Endurant stent graft in patients undergoing endovascular abdominal aortic aneurysm repair [J].
Bisdas, Theodosios ;
Weiss, Kristin ;
Eisenack, Markus ;
Austermann, Martin ;
Torsello, Giovanni ;
Donas, Konstantinos P. .
JOURNAL OF VASCULAR SURGERY, 2014, 60 (05) :1125-1131
[4]   Legal implications of pushing the endovascular envelope [J].
Brown, O. William .
JOURNAL OF VASCULAR SURGERY, 2012, 56 (01) :273-274
[5]   Stent-Graft Limb Deployment in the External Iliac Artery Increases the Risk of Limb Occlusion Following Endovascular AAA Repair [J].
Conway, Allan M. ;
Modarai, Bijan ;
Taylor, Peter R. ;
Carrell, Tom W. G. ;
Waltham, Matthew ;
Salter, Richard ;
Bell, Rachel E. .
JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (01) :79-85
[6]  
Donas KP, 2011, J VASC SURG, V53, P1223, DOI 10.1016/j.jvs.2010.10.121
[7]   Early results of the Endurant endograft system in patients with friendly and hostile infrarenal abdominal aortic aneurysm anatomy [J].
Georgiadis, George S. ;
Trellopoulos, George ;
Antoniou, George A. ;
Gallis, Konstantinos ;
Nikolopoulos, Evagelos S. ;
Kapoulas, Konstantinos C. ;
Pitta, Xanthi ;
Lazarides, Miltos K. .
JOURNAL OF VASCULAR SURGERY, 2011, 54 (03) :616-627
[8]   One year outcomes of the United States regulatory trial of the Endurant Stent Graft System [J].
Makaroun, Michel S. ;
Tuchek, Michael ;
Massop, Doug ;
Henretta, John ;
Rhee, Robert ;
Buckley, Clifford ;
Mehta, Manish ;
Ellozy, Sharif .
JOURNAL OF VASCULAR SURGERY, 2011, 54 (03) :601-608
[9]   Standard endovascular treatment of abdominal aortic aneurysms in patients with very short proximal necks using the Endurant stent graft [J].
Matsagkas, Miltiadis ;
Kouvelos, George ;
Peroulis, Michalis ;
Avgos, Stavros ;
Arnaoutoglou, Eleni ;
Papa, Nektario ;
Papadopoulos, George .
JOURNAL OF VASCULAR SURGERY, 2015, 61 (01) :9-15
[10]   Balloon dilation of a narrow distal aorta during bifurcated endograft placement: A reminder of the value of standard angioplasty techniques for increasing EVAR applicability [J].
Muhs, BE ;
Moll, FL ;
Verhagen, HJM .
JOURNAL OF ENDOVASCULAR THERAPY, 2006, 13 (01) :125-126