The on-chip measurement of absorbing species has proven to be challenging, particularly with respect to the sample pathlengths available in a miniaturised system. This paper demonstrates how the principles of total internal reflection can be utilised to form a liquid-core waveguide along a single microfluidic channel, increasing the sampling pathlength to 5 mm while maintaining a detection volume of <1 muL. This was achieved using the Teflon fluoropolymers PTFE, FEP and AF as cladding for the liquid-core waveguide. In conjunction with a 3D chip architecture, the use of the liquid-core waveguide enables more efficient use of the probing light beam along with easy and effective coupling of the source, microfluidic chip and the detection system. The confirmation that waveguiding was occurring was successfully demonstrated and the subsequent spectrophotometric analysis of crystal violet provided a linear calibration with reproducibility (<2.4% RSD) and limits of detection (<1.3 muM), comparable to absorbance measurements made with a standard UV-Vis spectrophotometer.
引用
收藏
页码:1336 / 1340
页数:5
相关论文
共 34 条
[1]   Spectrophotometric measurement of total inorganic carbon in aqueous solutions using a liquid core waveguide [J].
Byrne, RH ;
Liu, XW ;
Kaltenbacher, EA ;
Sell, K .
ANALYTICA CHIMICA ACTA, 2002, 451 (02) :221-229
[2]   Rectangular channels for lab-on-a-chip applications [J].
Ceriotti, L ;
Weible, K ;
de Rooij, NF ;
Verpoorte, E .
MICROELECTRONIC ENGINEERING, 2003, 67-8 :865-871
[3]   Chemical sensing using an integrated microfluidic system based on the Berthelot reaction [J].
Daridon, A ;
Sequeira, M ;
Pennarun-Thomas, G ;
Dirac, H ;
Krog, JP ;
Gravesen, P ;
Lichtenberg, J ;
Diamond, D ;
Verpoorte, E ;
de Rooij, NF .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) :235-243
[4]   Further studies into the development of a micro-FIA (μFIA) system based on electroosmotic flow for the determination of phosphate as orthophosphate [J].
Doku, GN ;
Haswell, SJ .
ANALYTICA CHIMICA ACTA, 1999, 382 (1-2) :1-13
[5]   Physical analysis of teflon coated capillary waveguides [J].
Dress, P ;
Belz, M ;
Klein, KF ;
Grattan, KTV ;
Franke, H .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) :278-284
[6]   Transport of small polar molecules across nonporous polymeric membranes - I. Experimental procedures and data analysis [J].
Ghoreyshi, AA ;
Farhadpour, FA ;
Soltanieh, M ;
Bansal, A .
JOURNAL OF MEMBRANE SCIENCE, 2003, 211 (02) :193-214
[7]  
GODDARD NJ, 1998, MICRO TOTAL ANAL SYS
[8]   Characterisation of a micro-total analytical system for the determination of nitrite with spectrophotometric detection [J].
Greenway, GM ;
Haswell, SJ ;
Petsul, PH .
ANALYTICA CHIMICA ACTA, 1999, 387 (01) :1-10
[9]   FABRICATION OF BURIED-CHANNEL WAVE-GUIDES ON SILICON SUBSTRATES USING SPIN-ON GLASS [J].
HOLMES, AS ;
SYMS, RRA ;
LI, M ;
GREEN, M .
APPLIED OPTICS, 1993, 32 (25) :4916-4921
[10]  
JACKMAN RJ, 2001, MICRO TOTAL ANAL SYS, P345