Intracranial pressure in hydrocephalus: impact of shunt adjustments and body positions

被引:35
作者
Farahmand, Dan [1 ]
Qvarlander, Sara [2 ]
Malm, Jan [3 ]
Wikkelso, Carsten [1 ]
Eklund, Anders [2 ]
Tisell, Magnus [1 ]
机构
[1] Univ Gothenburg, Hydrocephalus Res Unit, Inst Neurosci & Physiol, Sahlgrenska Acad, Gothenburg, Sweden
[2] Umea Univ, Dept Radiat, Umea, Sweden
[3] Umea Univ, Dept Clin Neurosci, Umea, Sweden
关键词
VALVE OPENING PRESSURE; FLUID PULSE PRESSURE; CLINICAL-EVALUATION; TECHNICAL REPORT; BRAINIT GROUP; DYNAMICS; PULSATILITY; MANAGEMENT; SENSORS; SYSTEM;
D O I
10.1136/jnnp-2014-307873
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background The association between intracranial pressure (ICP) and different shunt valve opening pressures in relation to body positions is fundamental for understanding the physiological function of the shunt. Objective To analyse the ICP and ICP wave amplitude (AMP) at different shunt settings and body positions in patients with hydrocephalus. Methods In this prospective study 15 patients with communicating hydrocephalus were implanted with a ligated adjustable ventriculoperitoneal shunt. They also received a portable intraparenchymatous ICP-monitoring device. Postoperative ICP and AMP were recorded with the patients in three different body positions (supine, sitting and walking) and with the shunt ligated and open at high, medium and low valve settings. In each patient 12 10 min segments were coded, blinded and analysed for mean ICP and mean AMP using an automated computer algorithm. Results Mean ICP and mean AMP were lower at all three valve settings compared with the ligated shunt state (p<0.001). Overall, when compared with the supine position, mean ICP was 11.5 +/- 1.1 (mean +/- SD) mm Hg lower when sitting and 10.5 +/- 1.1 mm Hg lower when walking (p<0.001). Mean ICP was overall 1.1 mm Hg higher (p=0.042) when walking compared with sitting. The maximal adjustability difference (highest vs lowest valve setting) was 4.4 mm Hg. Conclusions Changing from a supine to an upright position reduced ICP while AMP only increased at trend level. Lowering of the shunt valve opening pressure decreased ICP and AMP but the difference in mean ICP in vivo between the highest and lowest opening pressures was less than half that previously observed in vitro.
引用
收藏
页码:222 / 228
页数:7
相关论文
共 38 条
[1]   Quality and Safety of Home ICP Monitoring Compared with In-Hospital Monitoring [J].
Andresen, Morten ;
Juhler, Marianne ;
Munch, Tina Norgaard .
HYDROCEPHALUS, 2012, 113 :187-191
[2]  
[Anonymous], 2005, NEUROSURGERY
[3]   Evaluation of Strata NSC and Codman Hakim adjustable cerebrospinal fluid shunts and their corresponding antisiphon devices Laboratory investigation [J].
Arnell, Kai ;
Koskinen, Lars-Owe D. ;
Malam, Jan ;
Eklund, Anders .
JOURNAL OF NEUROSURGERY-PEDIATRICS, 2009, 3 (03) :166-172
[4]   CLINICAL OBSERVATIONS ON THE RELATIONSHIP BETWEEN CEREBROSPINAL-FLUID PULSE PRESSURE AND INTRACRANIAL-PRESSURE [J].
AVEZAAT, CJJ ;
VANEIJNDHOVEN, JHM .
ACTA NEUROCHIRURGICA, 1986, 79 (01) :13-29
[5]   Surgical management of idiopathic normal-pressure hydrocephalus [J].
Bergsneider, M ;
Black, PM ;
Klinge, P ;
Marmarou, A ;
Relkin, N .
NEUROSURGERY, 2005, 57 (03) :29-39
[6]   Relationship between valve opening pressure, body position, and intracranial pressure in normal pressure hydrocephalus: Paradigm for selection of programmable valve pressure setting [J].
Bergsneider, M ;
Yang, I ;
Hu, X ;
McArthur, DL ;
Cook, SW ;
Boscardin, WJ .
NEUROSURGERY, 2004, 55 (04) :851-858
[7]   Management of hydrocephalus with programmable valves after traumatic brain injury and subarachnoid hemorrhage [J].
Bergsneider, M .
CURRENT OPINION IN NEUROLOGY, 2000, 13 (06) :661-664
[8]   THE RELATIONSHIP BETWEEN VENTRICULAR FLUID PRESSURE AND BODY POSITION IN NORMAL SUBJECTS AND SUBJECTS WITH SHUNTS - A TELEMETRIC STUDY [J].
CHAPMAN, PH ;
COSMAN, ER ;
ARNOLD, MA .
NEUROSURGERY, 1990, 26 (02) :181-189
[9]   Bench test assessment of the new Raumedic Neurovent-P ICP sensor: a technical report by the BrainIT group [J].
Citerio, G ;
Piper, I ;
Cormio, M ;
Galli, D ;
Cazzaniga, S ;
Enblad, P ;
Nilsson, P ;
Contant, C ;
Chambers, I .
ACTA NEUROCHIRURGICA, 2004, 146 (11) :1221-1226
[10]   MULTICENTER CLINICAL ASSESSMENT OF THE RAUMEDIC NEUROVENT-P INTRACRANIAL PRESSURE SENSOR: A REPORT BY THE BRAINIT GROUP [J].
Citerio, Giuseppe ;
Piper, Ian ;
Chambers, Iain R. ;
Galli, Davide ;
Enblad, Per ;
Kiening, Karl ;
Ragauskas, Arminas ;
Sahuquillo, Juan ;
Gregson, Barbara .
NEUROSURGERY, 2008, 63 (06) :1152-1158