Femoral neck shape and the spatial distribution of its mineral mass varies with its size: Clinical and biomechanical implications

被引:62
作者
Zebaze, RMD
Jones, A
Welsh, F
Knackstedt, M
Seeman, E [1 ]
机构
[1] Univ Melbourne, Austin Hosp, Melbourne, Vic 3084, Australia
[2] Univ Aberdeen, Aberdeen, Scotland
[3] Australian Natl Univ, Dept Appl Math, RSPhysSE, Canberra, ACT, Australia
基金
澳大利亚研究理事会;
关键词
femoral neck size; shape; geometric indices of bone strength; volumetric bone mineral density;
D O I
10.1016/j.bone.2005.03.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The femoral neck (FN) is a cantilever with external and internal dimensions determining its size, shape, the spatial distribution of the mineralized cortical and trabecutar bone tissue mass, and its strength. Geometric indices of FN strength are often derived using FN dimensions estimated in vivo from dual X-ray absorptiometry (DXA) assuming that the FN cross section approximates a circle or a square. As DXA does not measure FN depth, we examined whether circular, square, or elliptical models of FN cross sections predict FN depth, and so its external volume, shape, volumetric bone mineral density (vBMD), and geometric indices of strength. We studied paired FN specimens from 13 Caucasian female cadavers (mean age 69 years, range 29 to 85) using DXA, micro-computed tomography (mu-CT), and direct calliper measurements. DXA accurately measured FN width (supero-inferior diameter) but models assuming a circular and a square cross section overestimated FN depth (antero-posterior diameter) and volume, and so underestimated vBMD by 15.0 +/- 5.8% (circular cross section) and by 33.2 +/- 4.6% (square cross section) (both P < 0.05). As depth was less than the width, an elliptical model with a constant depth/width ratio of 0.75 reduced the accuracy error in vBMD to 14.0 +/- 8.5% (P = 0.10). However, as FN width increased, FN depth increased relatively less. An elliptical model using a quadratic equation to mimic this changing in shape with increasing size reduced the error in vBMD to 4.4 +/- 7.7% (NS). Circular cross-section models overestimated section modulus at the mid-FN by about 51%. The elliptical models reduced the error two- to three fold. Images from micro-CT scanning show that the FN cross-sectional shape resembles an ellipse with the long axis and the maximum moment of inertia (I-max) oriented in the supero-inferior direction, and the cortical mass concentrated inferiorly. The larger the cross section, the more elliptical the shape, and the greater the I-max supero-inferiorly, while I-min (in the antero-posterior direction) remains relatively constant. The shape, spatial distribution of bone, and moments of inertia are likely to be adaptations to bending moments during bipedalism. Assuming the FN cross section approximates a circle or square produces errors in FN depth, volume, vBMD, and Geometric indices of bone strength. Studies are needed to determine the effects of a e, sex, and race on FN size and shape in health and disease. (c) 2005 Published by Elsevier Inc.
引用
收藏
页码:243 / 252
页数:10
相关论文
共 32 条
[1]   Characterisation of irregular spatial structures by parallel sets and integral geometric measures [J].
Arns, CH ;
Knackstedt, MA ;
Mecke, KR .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2004, 241 (1-3) :351-372
[2]  
Augat P, 1996, J BONE MINER RES, V11, P1356
[3]   PREDICTING FEMORAL-NECK STRENGTH FROM BONE-MINERAL DATA - A STRUCTURAL APPROACH [J].
BECK, TJ ;
RUFF, CB ;
WARDEN, KE ;
SCOTT, WW ;
RAO, GU .
INVESTIGATIVE RADIOLOGY, 1990, 25 (01) :6-18
[4]   The accuracy of peripheral skeletal assessment at the radius in estimating femoral bone density as measured by dual-energy X-ray absorptiometry: a comparative study of single-photon absorptiometry and computed tomography [J].
Boonen, S ;
Cheng, X ;
Nicholson, PHF ;
Verbeke, G ;
Broos, P ;
Dequeker, J .
JOURNAL OF INTERNAL MEDICINE, 1997, 242 (04) :323-328
[5]  
CARTER DR, 1992, J BONE MINER RES, V7, P137
[6]   Assessment of the strength of proximal femur in vitro: Relationship to femoral bone mineral density and femoral geometry [J].
Cheng, XG ;
Lowet, G ;
Boonen, S ;
Nicholson, PHF ;
Brys, P ;
Nijs, J ;
Dequeker, J .
BONE, 1997, 20 (03) :213-218
[7]  
CUMMINGS SR, 1994, J BONE MINER RES, V9, P1429
[8]  
CURREY JD, 2002, STRUCTURE MECH, pCH11
[9]   BODY SIZE, LOCOMOTION, AND LONG-BONE CROSS-SECTIONAL GEOMETRY IN INDRIID PRIMATES [J].
DEMES, B ;
JUNGERS, WL ;
SELPIEN, K .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1991, 86 (04) :537-547
[10]   Structural and biomechanical basis of sexual dimorphism in femoral neck fragility has its origins in growth and aging [J].
Duan, YB ;
Beck, TJ ;
Wang, XF ;
Seeman, E .
JOURNAL OF BONE AND MINERAL RESEARCH, 2003, 18 (10) :1766-1774