Accuracy Evaluation of Additively and Subtractively Fabricated Palatal Plate Orthodontic Appliances for Newborns and Infants-An In Vitro Study

被引:16
作者
Aretxabaleta, Maite [1 ]
Unkovskiy, Alexey [2 ,3 ,4 ,5 ]
Koos, Bernd [1 ]
Spintzyk, Sebastian [6 ]
Xepapadeas, Alexander B. [1 ]
机构
[1] Univ Hosp Tubingen, Dept Orthodont, Univ Ctr Dent Oral Med & Maxillofacial Surg, Osianderstr 2-8, D-72076 Tubingen, Germany
[2] Charite Univ Med Berlin, Dept Prosthodont Geriatr Dent & Craniomandibular, Assmannshauser Str 4-6, D-14197 Berlin, Germany
[3] Free Univ Berlin, Assmannshauser Str 4-6, D-14197 Berlin, Germany
[4] Humboldt Univ, Assmannshauser Str 4-6, D-14197 Berlin, Germany
[5] Sechenov First Moscow State Med Univ, Dept Dent Surg, Bolshaya Pirogovskaya St 19C1, Moscow 119146, Russia
[6] Univ Hosp Tubingen, Sect Med Mat Sci & Technol, Osianderstr 2-8, D-72076 Tubingen, Germany
关键词
digital workflow; SLA; DLP; trueness; precision; layer thickness; time efficiency; cleft palate plate; stimulation plate; Tubingen palatal plate; DENTURE BASE ADAPTATION;
D O I
10.3390/ma14154103
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Different approaches for digital workflows have already been presented for their use in palatal plates for newborns and infants. However, there is no evidence on the accuracy of CAD/CAM manufactured orthodontic appliances for this kind of application. This study evaluates trueness and precision provided by different CAM technologies and materials for these appliances. Samples of a standard palatal stimulation plate were manufactured using stereolithography (SLA), direct light processing (DLP) and subtractive manufacturing (SM). The effect of material (for SM) and layer thickness (for DLP) were also investigated. Specimens were digitized with a laboratory scanner (D2000, 3Shape) and analyzed with a 3D inspection software (Geomagic Control X, 3D systems). For quantitative analysis, differences between 3D datasets were measured using root mean square (RMS) error values for trueness and precision. For qualitative analysis, color maps were generated to detect locations of deviations within each sample. SM showed higher trueness and precision than AM technologies. Reducing layer thickness in DLP did not significantly increase accuracy, but prolonged manufacturing time. All materials and technologies met the clinically acceptable range and are appropriate for their use. DLP with 100 mu m layer thickness showed the highest efficiency, obtaining high trueness and precision within the lowest manufacturing time.
引用
收藏
页数:19
相关论文
共 39 条
  • [1] 3Shape A/S, 2017, 3SHAPE DENT SYST CAT 3SHAPE DENT SYST CAT
  • [2] Effects of two Postprocessing Methods onto Surface Dimension of in-Office Fabricated Stereolithographic Implant Surgical Guides
    Ammoun, Rami
    Dalal, Nishchal
    Abdulmajeed, Aous A.
    Deeb, George R.
    Bencharit, Sompop
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (01): : 71 - 75
  • [3] [Anonymous], 1994, Accuracy trueness and precision of measurement methods and results
  • [4] Comparison of additive and subtractive CAD/CAM materials for their potential use as Tubingen Palatal Plate: An in-vitro study on flexural strength
    Aretxabaleta, Maite
    Xepapadeas, Alexander B.
    Poets, Christian F.
    Koos, Bernd
    Spintzyk, Sebastian
    [J]. ADDITIVE MANUFACTURING, 2021, 37
  • [5] Fracture Load of an Orthodontic Appliance for Robin Sequence Treatment in a Digital Workflow
    Aretxabaleta, Maite
    Xepapadeas, Alexander B.
    Poets, Christian F.
    Koos, Bernd
    Spintzyk, Sebastian
    [J]. MATERIALS, 2021, 14 (02) : 1 - 17
  • [6] Castillo-Morales R, 1985, Zahnarztl Mitt, V75, P935
  • [7] Castillo-Morales R., 1982, SOZIALPADIATRIE, V1, P10
  • [8] Chate R A, 1995, Br J Orthod, V22, P299
  • [9] Edentulous jaw impression techniques: An in vivo comparison of trueness
    Chebib, Najla
    Kalberer, Nicole
    Srinivasan, Murali
    Maniewicz, Sabrina
    Perneger, Thomas
    Mueller, Frauke
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (04) : 623 - 630
  • [10] Dentaurum GmbH Co. KG, 2016, ORTHOCRYL INSTRUCTIO