A hybrid approach for fast simulation of x-ray computed tomography

被引:6
作者
Ay, M. R. [1 ]
Gafarian, P. [2 ]
Zaidi, H. [3 ]
机构
[1] Med Sci Univ Tehran, Dept Med Phys & Biomed Engn, Sch Med, Tehran, Iran
[2] Shahid Beheshti Univ, Dept Radiat Med, Tehran, Iran
[3] Univ Geneva, Div Nucl Med, CH-1211 Geneva, Switzerland
来源
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11 | 2007年
基金
瑞士国家科学基金会;
关键词
D O I
10.1109/NSSMIC.2007.4436797
中图分类号
O59 [应用物理学];
学科分类号
摘要
With the advent of powerful computers the use of Monte Carlo (MC) techniques for radiation transport simulation has become one of the most popular methods for modeling x-ray computed tomography (CT) scanners. One significant problem in the use of MC calculations is the presence of statistical uncertainties in the estimates. A simple but not practical way to decrease statistical uncertainties is to run MC simulations for sufficiently long time (large number of histories) and use efficient variance reduction techniques. In this paper, we propose a hybrid approach combining MC and analytical simulations to speed up x-ray CT modeling. In addition, an analytic method for modeling of beam hardening effect (BHE) in CT is proposed for fast generation of raw data for use in validation of BHE correction algorithms. In this method, the contribution of the primary component to the projections is calculated through analytical simulations using ray-tracing methods whereas the contribution of the scatter component is calculated using pure MC simulations. The final projections are determined by appropriate combination of both simulation results. The hybrid simulator and analytic BHE modelling were validated through comparison with experimental measurements and pure MC simulation of different phantoms performed on clinical CT scanners. In general, there is good agreement between the simulated and measured projections and reconstructed images. This work has demonstrated the feasibility of using the hybrid approach for fast and accurate modeling of CT scanners thus allowing to evaluate the effect of physical, geometrical and other design parameters on CT scanner performance and image quality. The results also validate the proposed method for analytical modeling of BHE which is a useful tool for fast generation of raw CT datasets.
引用
收藏
页码:3155 / +
页数:2
相关论文
共 50 条
  • [41] A Multiresolution Approach to Iterative Reconstruction Algorithms in X-Ray Computed Tomography
    De Witte, Yoni
    Vlassenbroeck, Jelle
    Van Hoorebeke, Luc
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2010, 19 (09) : 2419 - 2427
  • [42] Fast Three-Dimensional Focused X-ray Luminescence Computed Tomography
    Lun, Michael C.
    Fang, Yile
    Li, Changqing
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [43] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [44] Phase retrieval for hard X-ray computed tomography of samples with hybrid compositions
    Liu, Huiqiang
    Ren, Yuqi
    Guo, Han
    Xue, Yanling
    Xie, Honglan
    Xiao, Tiqiao
    Wu, Xizeng
    CHINESE OPTICS LETTERS, 2012, 10 (12)
  • [45] Hybrid deterministic and stochastic X-ray transport simulation for transmission computed tomography with advanced detector noise model
    Popescu, Lucretiu M.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [46] X-ray computed tomography of polymer composites
    Garcea, S. C.
    Wang, Y.
    Withers, P. J.
    COMPOSITES SCIENCE AND TECHNOLOGY, 2018, 156 : 305 - 319
  • [47] Development of dimensional X-ray computed tomography
    National Metrology Institute of Japan , National Institute of Advanced Industrial Science and Technology , 1-1-1 Umezono, Tsukuba
    Ibaraki
    305-8563, Japan
    Int. J. Autom. Technol., 5 (567-571): : 567 - 571
  • [48] Ptychographic X-ray computed tomography at the nanoscale
    Martin Dierolf
    Andreas Menzel
    Pierre Thibault
    Philipp Schneider
    Cameron M. Kewish
    Roger Wepf
    Oliver Bunk
    Franz Pfeiffer
    Nature, 2010, 467 : 436 - 439
  • [49] APPLIED X-RAY COMPUTED-TOMOGRAPHY
    BUYNAK, CF
    BOSSI, RH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4) : 772 - 774
  • [50] NOISE LIMITATIONS IN X-RAY COMPUTED TOMOGRAPHY
    TRETIAK, OJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (04) : 477 - 480