Time-of-flight magnetic resonance angiography at 7 tesla

被引:76
作者
Heverhagen, Johannes T. [1 ,2 ]
Bourekas, Eric [1 ]
Sammet, Steffen [1 ]
Knopp, Michael V. [1 ]
Schmalbrock, Petra [1 ]
机构
[1] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
[2] Philipps Univ, Dept Diagnost Radiol, Marburg, Germany
关键词
ultrahigh field; magnetic resonance imaging; angiography; comparative studies; time-of-flight;
D O I
10.1097/RLI.0b013e31817e9b2c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Magnetic resonance angiography (MRA) is noninvasive and does not require the application of high doses of contrast agents, and thus is used in the clinical routine for evaluation of cerebrovascular diseases, eg, aneurysm and arteriovenous malformations. However, more subtle microvascular disease usually cannot be seen with the resolution capabilities of standard field strength MRA. The purpose of this study was to evaluate the ability of 7-T time-of-flight (ToF) MRA to depict the arterial brain vasculature and to compare the results to data from 1.5 T and 3 T. Materials and Methods: The study was IRB approved and complied with The Health Insurance Portability and Accountability Act. All subjects gave written informed consent. Eight healthy volunteers (age: 36 +/- 10 years, 3 fermale, 5 male) were investigated using ToF MRA at 7 T, 3 T, and 1.5 T. Signal intensities of the large, primary vessels of the Circle of Willis were measured and signal-to-noise ratios were calculated. Visibility of smaller arteries was evaluated. Results: The results show that ultrahigh field allows depiction of the large vessels of the Circle of Willis. Although it provides only small increases in signal-to-noise ratios for these vessels, compared with 1.5 T and 3 T, it additionally demonstrates considerably more first and second-order branches. Conclusions: Because of its considerably enhanced potential to depict vessels of the Circle of Willis and its first- and second-order branches, ToF MRA at 7 T may become an important tool in future neuroradiology research and clinical care.
引用
收藏
页码:568 / 573
页数:6
相关论文
共 28 条
[21]   Radiation doses in interventional radiology procedures: The RAD-IR Study - Part I: Overall measures of dose [J].
Miller, DL ;
Balter, S ;
Cole, PE ;
Lu, HT ;
Schueler, BA ;
Geisinger, M ;
Berenstein, A ;
Albert, R ;
Georgia, JD ;
Noonan, PT ;
Cardella, JF ;
George, JS ;
Russell, EJ ;
Malisch, TW ;
Vogelzang, RL ;
Miller, GL ;
Anderson, J .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (06) :711-727
[22]   Multiple sclerosis as a vascular disease [J].
Minagar, A ;
Jy, W ;
Jimenez, JJ ;
Alexander, JS .
NEUROLOGICAL RESEARCH, 2006, 28 (03) :230-235
[23]   Aneurysm of the distal anterior inferior cerebellar artery at the medial branch: A case report and review of the literature [J].
Mizushima, H ;
Kobayashi, N ;
Yoshiharu, S ;
Kazuo, H ;
Dohi, K ;
Sasaki, K ;
Matsumoto, K .
SURGICAL NEUROLOGY, 1999, 52 (02) :137-142
[24]  
Molyneux AJ, 2004, AM J NEURORADIOL, V25, P39
[25]  
Nael K, 2006, AM J NEURORADIOL, V27, P2118
[26]   DETECTION OF CIRCLE OF WILLIS ANEURYSMS IN PATIENTS WITH ACUTE SUBARACHNOID HEMORRHAGE - A COMPARISON OF CT ANGIOGRAPHY AND DIGITAL SUBTRACTION ANGIOGRAPHY [J].
VIECO, PT ;
SHUMAN, WP ;
ALSOFROM, GF ;
GROSS, CE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :425-430
[27]   Sixteen-detector row CT angiography of the brain: Comparison of 3 different volumes of the contrast material [J].
Yoon, Dae Young ;
Lim, Kyoung Ja ;
Choi, Chul Soon ;
Chang, Suk Ki ;
Yun, Eun Joo ;
Seo, Young Lan ;
Lee, Yu-Jin ;
Moon, Jeung Hee ;
Park, Se Hyuck ;
Song, Hong Ki .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (05) :671-676
[28]   Complications with outpatient angiography and interventional procedures [J].
Young, N ;
Chi, KK ;
Ajaka, J ;
McKay, L ;
O'Neill, D ;
Wong, KP .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 25 (02) :123-126