Unicortical self-drilling external fixator pins reduce thermal effects during pin insertion

被引:6
作者
Greinwald, Markus [1 ]
Varady, Patrick A. [1 ]
Augat, Peter [1 ,2 ]
机构
[1] Trauma Ctr Murnau, Inst Biomech, Prof Kuntscher Str 8, D-82418 Murnau, Germany
[2] Paracelsus Med Univ, Inst Biomech, Salzburg, Austria
关键词
External fixation; Thermographic camera; Unicortical pin; Thermal necrosis; Pin insertion; BONE; COMPLICATIONS;
D O I
10.1007/s00068-017-0887-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
IntroductionExternal fixation is associated with the risk of pin loosening and pin infection potentially associated to thermal bone necrosis during pin insertion.ObjectiveThis study aims to investigate if the use of external fixator systems with unicortical pins reduces the heat production during pin insertion compared to fixators with bicortical pins.MethodsPorcine bone specimens were employed to determine bone temperatures during insertion of fixator pins. Two thermographic cameras were used for a simultaneous temperature measurement on the bone surface (top view) and a bone cross-section (front view). Self-drilling unicortical and bicortical pins were inserted at different rotational speeds: (30-600) rpm. Maximum and mean temperatures of the emerging bone debris, bone surface and bone cross-section were analyzed.ResultsMaximum temperatures of up to 7726 degrees C were measured during pin insertion in the emerging debris and up to 42 +/- 2 degrees C on the bone surface. Temperatures of the emerging debris increased with increasing rotational speeds. Bicortical pin insertion generated significantly higher temperatures at low insertion speed (30rpm)ConclusionThe insertion of external fixator pins can generate a considerable amount of heat around the pins, primarily emerging from bone debris and at higher insertion speeds. Our findings suggest that unicortical, self-drilling fixator pins have a decreased risk for thermal damage, both to the surrounding tissue and to the bone itself.
引用
收藏
页码:939 / 946
页数:8
相关论文
共 15 条
[1]   INCREASE OF STABILITY IN EXTERNAL FRACTURE FIXATION BY HYDROXYAPATITE-COATED BONE SCREWS [J].
AUGAT, P ;
CLAES, L ;
HANSELMANN, KF ;
SUGER, G ;
FLEISCHMANN, W .
JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (02) :99-104
[2]   Thermal osteonecrosis and bone drilling parameters revisited [J].
Augustin, Goran ;
Davila, Slavko ;
Mihoci, Kristijan ;
Udiljak, Toma ;
Vedrina, Denis Stjepan ;
Antabak, Anko .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (01) :71-77
[3]  
BERMAN AT, 1984, CLIN ORTHOP RELAT R, P284
[4]   Prevention and Management of Complications Arising from External Fixation Pin Sites [J].
Bibbo, Christopher ;
Brueggeman, Jon .
JOURNAL OF FOOT & ANKLE SURGERY, 2010, 49 (01) :87-92
[5]  
Della Rocca Gregory J, 2006, J Am Acad Orthop Surg, V14, pS131
[6]  
Fragomen Austin T, 2007, HSS J, V3, P13, DOI 10.1007/s11420-006-9025-0
[7]  
GREEN SA, 1983, CLIN ORTHOP RELAT R, P109
[8]   Successful limb salvage using the two-staged technique with internal fixation after osteodistraction in an effort to treat large segmental bone defects in the lower extremity [J].
Koettstorfer, J. ;
Hofbauer, M. ;
Wozasek, G. E. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (10) :1399-1405
[9]   Effects of one-plane and two-plane external fixation on sheep osteotomy healing and complications [J].
Krischak, GD ;
Janousek, A ;
Wolf, S ;
Augat, P ;
Kinzl, L ;
Claes, LE .
CLINICAL BIOMECHANICS, 2002, 17 (06) :470-476
[10]   Measuring temperature rise during orthopaedic surgical procedures [J].
Manoogian, Sarah ;
Lee, Adam K. ;
Widmaier, James C. .
MEDICAL ENGINEERING & PHYSICS, 2016, 38 (09) :1016-1020