EVALUATION OF EYE LENS DOSE TO WORKERS IN THE STEAM GENERATOR AT THE KOREAN OPTIMIZED POWER REACTOR 1000

被引:5
作者
Maeng, Sung Jun [1 ,2 ]
Kim, Jinhwan [2 ]
Cho, Gyuseong [2 ]
机构
[1] Korea Hydro & Nucl Power Co Ltd, Cent Res Inst, Daejeon 34101, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, 291 Daehak Ro, Daejeon, South Korea
关键词
D O I
10.1093/rpd/ncy038
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
ICRP (2011) revised the dose limit to the eye lens to 20 mSv/y based on a recent epidemiological study of radiation-induced cataracts. Maintenance of steam generators at nuclear power plants is one of the highest radiation-associated tasks within a non-uniform radiation field. This study aims to evaluate eye lens doses in the steam generators of the Korean OPR1000 design. The source term was characterized based on the CRUD-specific activity, and both the eye lens dose and organ dose were simulated using MCNP6 combined with an ICRP voxel phantom and a mesh phantom, respectively. The eye lens dose was determined to be 5.39E-02-9.43E-02 Sv/h, with a negligible effect by beta particles. As the effective dose was found to be 0.81-1.21 times the lens equivalent dose depending on the phantom angles, the former can be used to estimate the lens dose in the SG of the OPR1000 for radiation monitoring purposes.
引用
收藏
页码:374 / 381
页数:8
相关论文
共 19 条
[1]  
[Anonymous], 2015, OUT RAD MAN REP HANB, VKHNP
[2]  
[Anonymous], 2007, The 2007 Recommendations of the International Commission on Radiological Protection
[3]   Dose conversion coefficients for photon exposure of the human eye lens [J].
Behrens, R. ;
Dietze, G. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (02) :415-437
[4]   Monitoring the eye lens: which dose quantity is adequate? [J].
Behrens, R. ;
Dietze, G. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (14) :4047-4062
[5]  
Chosun University, 2016, SOURC TERM PRED STUD, P89
[6]  
Deshon J, 2005, 101173 EPRI
[7]  
Electric Power Research Institute, 2006, 1013507 TR EL POW RE
[8]   Use of smears for assessing removable contamination [J].
Frame, PW ;
Abelquist, EW .
HEALTH PHYSICS, 1999, 76 (05) :S57-S66
[9]  
International Commission on Radiation Protection, 2009, NON TRADITIONAL REF, V39
[10]  
International Commission on Radiation Protection, 2010, NON TRADITIONAL REF, V40