First clinical use of novel ablation catheter incorporating local impedance data

被引:59
作者
Martin, Claire A. [1 ,2 ,3 ]
Martin, Ruairidh [1 ,4 ]
Gajendragadkar, Parag R. [2 ]
Maury, Philippe [5 ]
Takigawa, Masateru [1 ]
Cheniti, Ghassen [1 ]
Frontera, Antonio [1 ]
Kitamura, Takeshi [1 ]
Duchateau, Josselin [1 ]
Vlachos, Konstantinos [1 ]
Bourier, Felix [1 ]
Lam, Anna [1 ]
Lord, Stephen [4 ]
Murray, Stephen [4 ]
Shephard, Ewen [4 ]
Pambrun, Thomas [1 ]
Denis, Arnaud [1 ]
Derval, Nicolas [1 ]
Hocini, Meleze [1 ]
Haissaguerre, Michel [1 ]
Jais, Pierre [1 ]
Sacher, Frederic [1 ]
机构
[1] LIRYC Hop Haut Leveque, Bordeaux, France
[2] Papworth Hosp NHS Fdn Trust, Cambridge, England
[3] Barts Heart Ctr, London, England
[4] Freeman Rd Hosp, Newcastle Upon Tyne, Tyne & Wear, England
[5] Hop Rangueil, Toulouse, France
关键词
atrial tachycardia; catheter ablation; electrophysiology; impedance; ventricular tachycardia; VENTRICULAR-TACHYCARDIA; ELECTRICAL-IMPEDANCE; MYOCARDIAL-INFARCTION; CONTACT; SCAR;
D O I
10.1111/jce.13654
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Successful catheter ablation is limited by both poor spatial resolution of abnormal local signals and inability to deliver an effective lesion due to poor tissue contact. We report first worldwide use of the Intellanav MiFi OI catheter (Boston Scientific), providing ultra-high density mapping and incorporating a "DirectSense" algorithm to measure local tissue impedance (LI). Methods and results: 31 patients (65 +/- 6 years, 20 male) underwent ablation. LI from the catheter, generator impedance (GI) and maximum electrogram amplitude were recorded in the blood pool, and in regions from healthy to dense scar before, during and after ablation. The catheter demonstrated clear nearfield signal where standard bipolar recordings included farfield signal. LI was lower in dense scar than either healthy tissue or blood pool, and demonstrated an exponential relationship with maximum electrogram amplitude. Maximum LI drop on ablation linearly correlated with initial LI. The median LI drop for successful lesions, resulting in lack of local tissue capture, was 16.0 Omega (12.1-19.8 Omega) for LV and 14.6 Omega (10.0-18.3 Omega) for LA, which was larger than for unsuccessful lesions (LV: 9.4 Omega [5.4-15.6 Omega] P = 0.001; LA: 6.8 Omega [4.7-13.0 Omega], P = 0.049). LI percentage drop was also significantly larger for successful than unsuccessful lesions (LV: 17.1 Omega [14.0-19.6 Omega] vs. 10.6 Omega (7.1-16.5 Omega) P = 0.002; LA: 14.2 Omega [10.8-19.5 Omega] vs. 7.5 Omega [5.1-11.0 Omega], P = 0.005). Conclusion: This novel catheter gives reproducible recordings of local impedance, which are dependent on scar level. Absolute LI drop, and also percentage drop, on ablation may give an indication of tissue contact and subsequent effective lesion formation.
引用
收藏
页码:1197 / 1206
页数:10
相关论文
共 21 条
[11]   Use of microelectrode near-field signals to determine catheter contact [J].
Levy, Mathew R. ;
Merchant, Faisal M. ;
Langberg, Jonathan J. ;
Delurgio, David B. .
JOURNAL OF ARRHYTHMIA, 2018, 34 (01) :23-29
[12]   Electrogram Characteristics of Ablated and Non-Ablated Myocardium in Humans: A Comparison of Miniaturized Embedded Electrodes and Conventional Ablation Electrodes [J].
Lloyd, Michael S. ;
Hoskins, Michael H. ;
Shah, Anand D. ;
Langberg, Jonathan J. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (07) :820-824
[13]   Initial impedance decrease as an indicator of good catheter contact: Insights from radiofrequency ablation with force sensing catheters [J].
Reichlin, Tobias ;
Knecht, Sven ;
Lane, Christopher ;
Kuehne, Michael ;
Nof, Eyal ;
Chopra, Nagesh ;
Tadros, Thomas M. ;
Reddy, Vivek Y. ;
Schaer, Beat ;
John, Roy M. ;
Osswald, Stefan ;
Stevenson, William G. ;
Sticherling, Christian ;
Michaud, Gregory F. .
HEART RHYTHM, 2014, 11 (02) :194-201
[14]   Electrical impedance properties of normal and chronically infarcted left ventricular myocardium [J].
Schwartzman, D ;
Chang, I ;
Michele, JJ ;
Mirotznik, MS ;
Foster, KR .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1999, 3 (03) :213-224
[15]   ELECTRICAL IMPEDANCE OF CARDIAC MUSCLE [J].
SPERELAKIS, N ;
HOSHIKO, T .
CIRCULATION RESEARCH, 1961, 9 (06) :1280-&
[16]  
Sulkin M, 2017, HEART RHYTHM, V14, P5
[17]  
Tung R, 2016, CIRC ARRHYTHM ELECTR, V9
[18]   Recognition of far-field electrograms during entrainment mapping of ventricular tachycardia [J].
Tung, S ;
Soejima, K ;
Maisel, WH ;
Suzuki, M ;
Epstein, L ;
Stevenson, WG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (01) :110-115
[19]   Percutaneous electrocatheter technique for on-line detection of healed transmural myocardial infarction [J].
Warren, M ;
Bragós, R ;
Casas, O ;
Rodríguez-Sinovas, A ;
Rosell, J ;
Anivarro, I ;
Cinca, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (08) :1283-1287
[20]   Three-dimensional endocardial impedance mapping: a new approach for myocardial infarction assessment [J].
Wolf, T ;
Gepstein, L ;
Hayam, G ;
Zaretzky, A ;
Shofty, R ;
Kirshenbaum, D ;
Uretzky, G ;
Oron, U ;
Ben-Haim, SA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 280 (01) :H179-H188