Fault-Tolerant Operation of a Battery-Energy-Storage System Based on a Multilevel Cascade PWM Converter With Star Configuration

被引:183
作者
Maharjan, Laxman [1 ]
Yamagishi, Tsukasa [1 ]
Akagi, Hirofumi [1 ]
Asakura, Jun [2 ]
机构
[1] Tokyo Inst Technol, Dept Elect & Elect Engn, Tokyo 1528552, Japan
[2] Panasonic Corp, Energy Co, Moriguchi, Osaka 5708511, Japan
关键词
Battery-energy-storage system (BESS); cascade converters; fault-tolerant control; neutral shift; state-of-charge (SOC) balancing; STATCOM; DRIVE; PERFORMANCE; STRATEGY; INVERTER;
D O I
10.1109/TPEL.2010.2047407
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper focuses on fault-tolerant control for a battery-energy-storage system based on a multilevel cascade pulsewidth-modulation (PWM) converter with star configuration. During the occurrence of a single-converter-cell or single-battery-unit fault, the fault-tolerant control enables continuous operation and maintains state-of-charge balancing of the remaining healthy battery units. This enhances both system reliability and availability. A 200-V, 10-kW, 3.6-kW . h laboratory system combining a three-phase cascade PWM converter with nine nickel-metal-hydride battery units is designed, constructed, and tested to verify the validity and effectiveness of the proposed fault-tolerant control.
引用
收藏
页码:2386 / 2396
页数:11
相关论文
共 37 条
[21]   State-of-Charge (SOC)-Balancing Control of a Battery Energy Storage System Based on a Cascade PWM Converter [J].
Maharjan, Laxman ;
Inoue, Shigenori ;
Akagi, Hirofumi ;
Asakura, Jun .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (5-6) :1628-1636
[22]   Power-electronic systems for the grid integration of renewable energy sources:: A survey [J].
Manuel Carrasco, Juan ;
Franquelo, Leopoldo G. ;
Bialasiewicz, Jan T. ;
Galvan, Eduardo ;
Portillo, Ramon ;
Martin Prats, Maria ;
Ignacio Leon, Jose ;
Moreno-Alfonso, Narciso .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (04) :1002-1016
[23]   A Nonconventional Power Converter for Plasma Stabilization [J].
Marchesoni, Mario ;
Mazzucchelli, Maurizio ;
Tenconi, Sandro .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1990, 5 (02) :212-219
[24]  
Osman R. H., 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370), P2662, DOI 10.1109/IAS.1999.799213
[25]  
Peng F. Z., 1997, U.S. Patent, Patent No. [5 642 275, 5642275]
[26]  
Peng FZ, 1997, IEEE T IND APPL, V33, P748, DOI 10.1109/28.585865
[27]  
Peng FZ, 1996, IEEE T IND APPL, V32, P1130, DOI 10.1109/28.536875
[28]   Methods for state-of-charge determination and their applications [J].
Piller, S ;
Perrin, M ;
Jossen, A .
JOURNAL OF POWER SOURCES, 2001, 96 (01) :113-120
[29]   Failures-tolerance and remedial strategies of a PWM multicell inverter [J].
Richardeau, F ;
Baudesson, P ;
Meynard, TA .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2002, 17 (06) :905-912
[30]   Operation of a medium-voltage drive under faulty conditions [J].
Rodríguez, J ;
Hammond, PW ;
Pontt, J ;
Musalem, R ;
Lezana, P ;
Escobar, MJ .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2005, 52 (04) :1080-1085