An Aspiration Material Preparation System: Application of a New Liquid-Based Cytology Technique for Fine-Needle Aspiration of the Breast

被引:3
作者
Sakakibara, Eiichi [1 ]
Kimachi, Setsuo [1 ]
Hashimoto, Katsunori [3 ]
Inagaki, Hiroshi [2 ]
Nagasaka, Tetsuro [3 ]
Wakusawa, Shinya [3 ]
Yokoi, Toyoharu [4 ]
机构
[1] Tokoname Municipal Hosp, Dept Cytopathol, Tokoname, Japan
[2] Nagoya City Univ, Dept Pathol, Grad Sch Med Sci, Nagoya, Aichi, Japan
[3] Nagoya Univ, Sch Hlth Sci, Dept Med Technol, Nagoya, Aichi 4648601, Japan
[4] Aichi Med Univ Hosp, Dept Diagnost Pathol, Nagakute, Aichi, Japan
关键词
AMAPS; Breast; Fine-needle aspiration; Liquid-based cytology; CONVENTIONAL SMEAR; CERVICAL CYTOLOGY; THINPREP; SPECIMENS;
D O I
10.1159/000320857
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Objective To evaluate the usefulness of our original liquid-based cell preparation system AMAPS (aspiration material preparation system) and to compare it with the AutoSmear system in breast aspiration cytology Study Design A total of 487 specimens of fine-needle aspiration cytology of the breast were retrieved, of which 250 were processed with AMAPS and 237 with the AutoSmear method (before the introduction of AMAPS) A final histological diagnosis was obtained by an excisional biopsy or a surgical resection in 148 cases Results Cell recovery rates were significantly improved with AMAPS (96 8 and 991% in Papanicolaou and Diff-Quik, respectively) compared with the AutoSmear method (40 9 and 42 3%, respectively, p < 0 01) Within-run and day-to-day reproducibility of cell recovery was satisfactory, with coefficients of variations of 6 8 and 8 7%, respectively Following the introduction of AMAPS in breast cytology, the unsatisfactory rate decreased significantly (from 160 to 8 8%, p < 001), while the diagnostic sensitivity for malignancy did not change (97 8 to 98 1%) Moreover, the diagnostic specificity for benign lesions increased from 75 to 93 8%, thus decreasing the excision rate of fibrocystic disease Conclusion AMAPS may serve as an alternative to the conventional technique or commercially available liquid-based cytology systems Copyright (C) 2010 S Karger AG Basel
引用
收藏
页码:92 / 99
页数:8
相关论文
共 15 条
[1]  
Bédard YC, 1999, AM J CLIN PATHOL, V111, P523
[2]  
Biscotti CV, 1999, DIAGN CYTOPATHOL, V21, P137, DOI 10.1002/(SICI)1097-0339(199908)21:2<137::AID-DC11>3.0.CO
[3]  
2-O
[4]   Comparison of ThinPrep and conventional preparations on fine needle aspiration cytology material [J].
Dey, P ;
Luthra, UK ;
George, J ;
Zuhairy, F ;
George, SS ;
Haji, BI .
ACTA CYTOLOGICA, 2000, 44 (01) :46-50
[5]   THE EFFICACY OF AN AUTOMATED PREPARATION DEVICE FOR CERVICAL CYTOLOGY [J].
HUTCHINSON, ML ;
CASSIN, CM ;
BALL, HG .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1991, 96 (03) :300-305
[6]  
HUTCHINSON ML, 1992, ACTA CYTOL, V36, P499
[7]   EVALUATION OF CYTOCENTRIFUGE APPARATUS WITH SPECIAL REFERENCE TO THE CELLULAR-RECOVERY RATE [J].
KOBAYASHI, TK ;
UEDA, M ;
YAMAKI, T ;
YAKUSHIJI, M .
DIAGNOSTIC CYTOPATHOLOGY, 1992, 8 (04) :420-423
[8]  
Lee KR, 1996, ACTA CYTOL, V40, P895
[9]  
Lee YP, 2008, J KOREAN PHYS SOC, V52, pS1
[10]  
Michael CW, 2000, DIAGN CYTOPATHOL, V23, P6, DOI 10.1002/1097-0339(200007)23:1<6::AID-DC2>3.3.CO