Eccentric correction for off-axis vision in central visual field loss

被引:32
|
作者
Gustafsson, J
Unsbo, P
机构
[1] Royal Inst Technol, Stockholm, Sweden
[2] Lund Univ, Dept Design Sci, Div Rehabil Engn Res, Certec, Stockholm, Sweden
关键词
aberrations; oblique astigmatism; central scotoma; central visual field loss; central field loss; eccentric correction; eccentric fixation; preferred retinal locus;
D O I
10.1097/00006324-200307000-00015
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background. Subjects with absolute central visual field loss use. eccentric fixation and magnifying devices to utilize their residual vision. This preliminary study investigated the importance of an accurate eccentric correction of off-axis refractive errors to optimize the residual visual function for these subjects. Methods. Photorefraction using the PowerRefractor instrument was used to evaluate the ametropia in eccentric fixation angles. Methods were adapted for measuring visual acuity outside the macula using filtered optotypes from high-pass resolution perimetry. Optical corrections were implemented, and the visual function of subjects with central visual field loss was measured with and without eccentric correction. Results. Of the seven cases reported, five experienced an improvement in visual function in their preferred retinal locus with eccentric refraction. Conclusions. The main result was that optical correction for better image quality on the peripheral retina is important for the vision of subjects with central visual field loss, objectively as well as subjectively.
引用
收藏
页码:535 / 541
页数:7
相关论文
共 20 条
  • [1] Eccentric Gaze Direction in Patients with Central Field Loss
    Verezen, Cornelis A.
    Hoyng, Carel B.
    Meulendijks, Carina F. M.
    Keunen, Jan E. E.
    Klevering, B. Jeroen
    OPTOMETRY AND VISION SCIENCE, 2011, 88 (10) : 1164 - 1171
  • [2] Off-axis wave front measurements for optical correction in eccentric viewing -: art. no. 034002
    Lundström, L
    Unsbo, P
    Gustafsson, J
    JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (03)
  • [3] OBLIQUE CENTRAL REFRACTION IN SPHEROCYLINDRICAL LENSES TILTED AROUND AN OFF-AXIS MERIDIAN
    KEATING, MP
    OPTOMETRY AND VISION SCIENCE, 1993, 70 (10) : 785 - 791
  • [4] Visual stabilization of posture in persons with central visual field loss
    Turano, KA
    Dagnelie, G
    Herdman, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (08) : 1483 - 1491
  • [5] Preference of low vision devices in patients with central field loss and peripheral field loss
    Gopalakrishnan, Sarika
    Paramasivan, Gaurav
    Sathyaprasath, Mathangi
    Raman, Rajiv
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2021, 35 (04) : 286 - 292
  • [6] The value of Tablets as reading aids for individuals with central visual field loss: an evaluation of eccentric reading with static and scrolling text
    Walker, Robin
    Bryan, Lauren
    Harvey, Hannah
    Riazi, Afsane
    Anderson, Stephen J.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2016, 36 (04) : 459 - 464
  • [8] Design of an off-axis see-through display based on a dynamic phase correction approach
    Beuret, Marc
    Twardowski, Patrice
    Fontaine, Joel
    OPTICS EXPRESS, 2011, 19 (20): : 19688 - 19701
  • [9] Visual Field Dependence Persists in Age-Related Central Visual Field Loss
    Agathos, Catherine P.
    Shanidze, Natela M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (02)
  • [10] Visual brain plasticity induced by central and peripheral visual field loss
    Nicolae Sanda
    Leonardo Cerliani
    Colas N. Authié
    Norman Sabbah
    José-Alain Sahel
    Christophe Habas
    Avinoam B. Safran
    Michel Thiebaut de Schotten
    Brain Structure and Function, 2018, 223 : 3473 - 3485