Dimensional metrology with X-ray CT: A comparison with CMM measurements on internal features and compliant structures

被引:96
作者
Villarraga-Gomez, Herminso [1 ,2 ,4 ]
Lee, ChaBum [3 ]
Smith, Stuart T. [1 ,2 ]
机构
[1] Univ North Carolina Charlotte, Ctr Precis Metrol, Charlotte, NC 28223 USA
[2] Univ North Carolina Charlotte, Dept Phys & Opt Sci, Charlotte, NC 28223 USA
[3] Tennessee Technol Univ, Cookeville, TN 38505 USA
[4] Nikon Metrol Inc, 12701 Grand River Ave, Brighton, MI 48116 USA
来源
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY | 2018年 / 51卷
关键词
Dimensional metrology; Nondestructive inspection; X-ray computed tomography; Measurement uncertainty; CMM; COMPUTED-TOMOGRAPHY METROLOGY; REFERENCE TEMPERATURE; PROBING SYSTEMS; UNCERTAINTY; EVOLUTION; ACCURACY; MODELS;
D O I
10.1016/j.precisioneng.2017.08.021
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
X-ray computed tomography (CT) is uniquely suited for dimensional measurement of components having internal geometry, difficult-to-reach part features, and easy-to-deform or flexible structures. Through the development of standards it is also becoming accepted as a metrology tool. The objectives of this study are to compare dimensional measurements on artifacts containing internal structures and mechanically compliant features using current state-of-the-art CT and coordinate measure machine (CMM) techniques. It also aims to discuss some of the issues with recently developed standards for CT measurement uncertainty estimation. To illustrate the challenges of CMM and the potential of X-ray CT for reliable dimensional inspection, two different problems are presented: 1) characterization of internal geometry in a metallic artifact that has features inaccessible to tactile or vision-based measurement techniques; and 2) evaluation of dimensional measurement of diameters, form, and relative distances in the components of a flexible object with stems that bend due to mechanical contact by tactile instruments, e.g., CMM. In addition, some issues with the direct application of the ISO 15530 series for the estimation of CT measurement uncertainties are discussed, and a generalized formalism for uncertainty budgeting in CT metrology (still based on the ISO 15530 guidelines but with some differences) is applied to the measurements presented throughout this paper. For dimensions of geometric features ranging from 0.6 mm to 65 mm, a comparison between CT and CMM measurements typically resulted in differences of approximately 5 mu m or less for most of the measurements, while expanded uncertainties computed for the CT measurements ranged from 1 to 20 mu m. CT measurements on the internal geometries resulted in uncertainties comparable to CMM data that were obtained with the metallic artifact disassembled. However, in the particular case of measuring compliant structures, the conventional CMM strategies led to large systematic errors in the measurements. It is demonstrated that using extrapolation methods, measurements from these two systems converged to within +/- 2 mu m.
引用
收藏
页码:291 / 307
页数:17
相关论文
共 141 条
[1]  
Agilent Technologies Inc, 2007, MAT EXP COEFF LIN TH
[2]  
Aldebert P., 1984, High Temperatures - High Pressures, V16, P127
[3]  
Aloisi V., 2016, CASE STUDIES NONDEST, V6, P104, DOI [DOI 10.1016/j.csndt.2016.05.005, 10.1016/j.csndt.2016.05.005]
[4]  
Amirkhanov A., 2013, PROC SCCG SPRING C C, P81
[5]  
Andrew V, 2009, P 9 INT C EXH LAS ME
[6]   Comparison on Computed Tomography using industrial items [J].
Angel, J. ;
De Chiffre, L. .
CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2014, 63 (01) :473-476
[7]  
Angel J., 2013, INTERLABORATORY COMP
[8]  
Angel JAB, 2014, THESIS
[9]  
[Anonymous], 2015, 263021 VDIVDE
[10]  
[Anonymous], 2011, 263013 VDIVDE