Phase transformation of a zirconia ceramic head after total hip arthroplasty

被引:136
作者
Haraguchi, K [1 ]
Sugano, N [1 ]
Nishii, T [1 ]
Miki, H [1 ]
Oka, K [1 ]
Yoshikawa, H [1 ]
机构
[1] Osaka Univ, Sch Med, Dept Orthopaed Surg, Suita, Osaka 5650871, Japan
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2001年 / 83B卷 / 07期
关键词
D O I
10.1302/0301-620X.83B7.12122
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We report two cases of surface deterioration of a zirconia ceramic femoral head associated with phase transformation after total hip arthroplasty. One head was retrieved at revision due to recurrent dislocation after six years and the other because of failure of the locking mechanism of the polyethylene liner after three years. The monoclinic content of the zirconia ceramics rose from 1% to about 30% on the surface of the heads. SEM revealed numerous craters indicating extraction of the zirconia ceramics at the surface. Surface roughness increased from an initial value of 0.006 mum up to 0.12 mum. This is the first report to show that phase transformation of zirconia ceramics causes deterioration of the surface roughness of the head in vivo after total hip arthroplasty.
引用
收藏
页码:996 / 1000
页数:5
相关论文
共 12 条
[1]   Poor eight-year survival of cemented zirconia-polyethylene total hip replacements [J].
Allain, J ;
Le Mouel, S ;
Goutallier, D ;
Voisin, MC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :835-842
[2]   Zirconia as a sliding material -: Histologic, laboratory, and clinical data [J].
Cales, B .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (379) :94-112
[3]  
Chevalier J, 1999, J AM CERAM SOC, V82, P2150
[4]  
Hamada Y, 1999, J BIOMED MATER RES, V48, P301, DOI 10.1002/(SICI)1097-4636(1999)48:3<301::AID-JBM14>3.0.CO
[5]  
2-9
[6]   Ceramics in orthopaedics [J].
Hamadouche, M ;
Sedel, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1095-1099
[7]  
HERNIGOU P, 2000, P 67 ANN M AM AC ORT
[8]   Frictional heating of bearing materials tested in a hip joint wear simulator [J].
Lu, Z ;
McKellop, H .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (01) :101-108
[9]   Late dislocations after cementless total hip arthroplasty resulting from polyethylene wear [J].
Orozco, F ;
Hozack, WJ .
JOURNAL OF ARTHROPLASTY, 2000, 15 (08) :1059-1063
[10]   Zirconia as a ceramic biomaterial [J].
Piconi, C ;
Maccauro, G .
BIOMATERIALS, 1999, 20 (01) :1-25