Infection After Spanning External Fixation for High-Energy Tibial Plateau Fractures: Is Pin Site-Plate Overlap a Problem?

被引:46
作者
Laible, Catherine [1 ]
Earl-Royal, Emily [1 ]
Davidovitch, Roy [1 ]
Walsh, Mike [1 ]
Egol, Kenneth A. [1 ]
机构
[1] NYU, Dept Orthopaed Surg, Hosp Joint Dis, New York, NY USA
关键词
tibial plateau fracture; spanning external fixation; staged management; infectious complications; pin-plate overlap; INTERNAL-FIXATION; MANAGEMENT; COMPLICATIONS; PROTOCOL;
D O I
10.1097/BOT.0b013e31821cfb7a
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: The purpose of this study was to determine whether overlap between temporary external fixator pins and definitive plate fixation correlates with infection in high-energy tibial plateau fractures. Design: Retrospective chart and radiographic review. Setting: Academic medical center. Patients: Seventy-nine patients with unilateral high-energy tibial plateau fractures formed the basis of this report. Intervention: Placement of knee-spanning external fixation followed by delayed internal fixation for high-energy tibial plateau fractures treated at our institution between 2000 and 2008. Methods: Demographic patient information was reviewed. Radiographs were reviewed to assess for the presence of overlap between the temporary external fixator pins and the definitive plate fixation. Fisher exact and t test analyses were performed to compare those patients who had overlap and those who did not and were used to determine whether this was a factor in the development of a postoperative infection. Main Outcome Measurements: Development of infection in those whose external fixation pin sites overlapped with the definitive internal fixation device compared with those whose pin sites did not overlap with definitive plate and screws. Results: Six knees in six patients developed deep infections requiring serial irrigation and debridement and intravenous antibiotics. Of these six infections, three were in patients with closed fractures and three in patients with open fractures. Two of these six infections followed definitive plate fixation that overlapped the external fixator pin sites with an average of 4.2 cm of overlap. In the four patients who developed an infection and had no overlap, the average distance between the tip of the plate to the first external fixator pin was 6.3 cm. There was no correlation seen between infection and distance from pin to plate, pin-plate overlap distance, time in the external fixator, open fracture, classification of fracture, sex of the patient, age of the patient, or healing status of the fracture. Conclusion: Fears of definitive fracture fixation site contamination from external fixator pins do not appear to be clinically grounded. When needed, we recommend the use of a temporary external fixation construct with pin placement that provides for the best reduction and stability of the fracture, regardless of plans for future surgery.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 30 条
[1]   Early outcome of hybrid external fixation for fracture of the distal tibia [J].
Anglen, JO .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (02) :92-97
[2]   Functional outcomes of severe bicondylar plateau fractures treated with dual incisions and medial and lateral plates [J].
Barei, David P. ;
Nork, Sean E. ;
Mills, William J. ;
Coles, Chad P. ;
Henley, M. Bradford ;
Benirschke, Stephen K. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (08) :1713-1721
[3]   Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique [J].
Barei, DP ;
Nork, SE ;
Mills, WJ ;
Henley, MB ;
Benirschke, SK .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (10) :649-657
[4]   High-energy tibial plateau fractures [J].
Berkson, EM ;
Virkus, WW .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2006, 14 (01) :20-31
[5]  
Browner B, 1998, SKELETAL TRAUMA FRAC, P280
[6]  
Bucholz RW, 2006, ROCKWOOD GREENS FRAC, P2015
[7]   Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures - Results of a multicenter, prospective, randomized clinical trial [J].
McKee M.D. ;
Pirani S.P. ;
Stephen D.J.G. ;
Feibel R. ;
Powell J.N. ;
McCormack R. ;
Schemitsch E.H. ;
Kreder H.J. ;
Sekeramayi F. ;
Zomar M. ;
Wild L.M. ;
Buckley R. ;
Richards R.R. ;
Waddell J.P. ;
Daniels T.R. ;
Bogoch E.R. ;
Finkelstein J. ;
Axelrod T. ;
Perey B. ;
MacPherson H. ;
Goetz T. ;
Pate G. ;
Penner M. ;
Giachino A. ;
Barei D. ;
Veri J.-P. ;
Bulmer B. ;
Conlin L. ;
Elves L. ;
Erho C. ;
Moon K. ;
Kimmel E. ;
Conway A. ;
Hrushowy H. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (12) :2613-2623
[8]  
Canale ST, 2002, CAMPBELLS OPERATIVE, P2766
[9]   Treatment of high-energy tibial plateau fractures by the Ilizarov circular fixator [J].
Dendrinos, GK ;
Kontos, S ;
Katsenis, D ;
Dalas, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (05) :710-717
[10]  
Dickson KF, 2001, INJURY, V32, pD92