Lung surface deformation prediction from spirometry measurement and chest wall surface motion

被引:7
作者
Tehrani, Joubin Nasehi [1 ]
McEwan, Alistair [2 ]
Wang, Jing [1 ]
机构
[1] UT Southwestern Med Ctr, Dept Radiat Oncol, Dallas, TX 75235 USA
[2] Univ Sydney, Sch Elect & Informat Engn, Sydney, NSW 2006, Australia
基金
美国国家卫生研究院;
关键词
lung deformation; tumor motion prediction; finite element modeling; surrogate signals; canonical correlation analysis; RESPIRATION-GATED RADIOTHERAPY; TUMOR TRACKING; IMAGE REGISTRATION; CANCER RADIOTHERAPY; RADIATION-THERAPY; MRI; SEGMENTATION; PARAMETERS; ACCURACY; 4D-CT;
D O I
10.1118/1.4962479
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors have developed and evaluated a method to predict lung surface motion based on spirometry measurements, and chest and abdomen motion at selected locations. Methods: A patient-specific 3D triangular surface mesh of the lung region was obtained at the end expiratory phase by the threshold-based segmentation method. Lung flow volume changes were recorded with a spirometer for each patient. A total of 192 selected points at a regular spacing of 2x2 cm matrix points were used to detect chest wall motion over a total area of 32x24 cm covering the chest and abdomen surfaces. QR factorization with column pivoting was employed to remove redundant observations of the chest and abdominal areas. To create a statistical model between the lung surface and the corresponding surrogate signals, the authors developed a predictive model based on canonical ridge regression. Two unique weighting vectors were selected for each vertex on the lung surface; they were optimized during the training process using all other 4D-CT phases except for the test inspiration phase. These parameters were employed to predict the vertex locations of a testing data set. Results: The position of each lung surface mesh vertex was estimated from the motion at selected positions within the chest wall surface and from spirometry measurements in ten lung cancer patients. The average estimation of the 98th error percentile for the end inspiration phase was less than 1 mm (AP = 0.9 mm, RL = 0.6 mm, and SI = 0.8 mm). The vertices located at the lower region of the lung had a larger estimation error as compared with those within the upper region of the lung. The average landmark motion errors, derived from the biomechanical modeling using real surface deformation vector fields (SDVFs), and the predicted SDVFs were 3.0 and 3.1 mm, respectively. Conclusions: Our newly developed predictive model provides a noninvasive approach to derive lung boundary conditions. The proposed system can be used with personalized biomechanical respiration modeling to derive lung tumor motion during radiation therapy from noninvasive measurements. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:5493 / 5502
页数:10
相关论文
共 48 条
[1]   Sliding characteristic and material compressibility of human lung: Parametric study and verification [J].
Al-Mayah, A. ;
Moseley, J. ;
Velec, M. ;
Brock, K. K. .
MEDICAL PHYSICS, 2009, 36 (10) :4625-4633
[2]   Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT [J].
Beddar, A. Sam ;
Kainz, Kristofer ;
Briere, Tina Marie ;
Tsunashima, Yoshikazu ;
Pan, Tinsu ;
Prado, Karl ;
Mohan, Radhe ;
Gillin, Michael ;
Krishnan, Sunil .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (02) :630-638
[3]   Accuracy of finite element model-based multi-organ deformable image registration [J].
Brock, KK ;
Sharpe, MB ;
Dawson, LA ;
Kim, SM ;
Jaffray, DA .
MEDICAL PHYSICS, 2005, 32 (06) :1647-1659
[4]  
Businger P., 1965, NUMER MATH, V7, P269, DOI DOI 10.1007/BF01436084
[5]   Direct measurement of lung motion using hyperpolarized helium-3 MR tagging [J].
Cai, Jing ;
Miller, G. Wilson ;
Altes, Talissa A. ;
Read, Paul W. ;
Benedict, Stanley H. ;
De lange, Eduard E. ;
Cates, Gordon D. ;
Brookeman, James R. ;
Mugler, John P., III ;
Sheng, Ke .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03) :650-653
[6]   MRI-guided tumor tracking in lung cancer radiotherapy [J].
Cervino, Laura I. ;
Du, Jiang ;
Jiang, Steve B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (13) :3773-3785
[7]   Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patients [J].
Chen, QS ;
Weinhous, MS ;
Deibel, FC ;
Ciezki, JP ;
Macklis, RM .
MEDICAL PHYSICS, 2001, 28 (09) :1850-1856
[8]  
Cignoni P, 2008, ERCIM NEWS, V73, P6
[9]   Proof of concept of MRI-guided tracked radiation delivery: tracking one-dimensional motion [J].
Crijns, S. P. M. ;
Raaymakers, B. W. ;
Lagendijk, J. J. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (23) :7863-7872
[10]   Predictive modeling of lung motion over the entire respiratory cycle using measured pressure-volume data, 4DCT images, and finite-element analysis [J].
Eom, Jaesung ;
Xu, Xie George ;
De, Suvranu ;
Shi, Chengyu .
MEDICAL PHYSICS, 2010, 37 (08) :4389-4400