Evaluation of interproximal reduction in individual teeth, and full arch assessment in clear aligner therapy: digital planning versus 3D model analysis after reduction

被引:14
作者
Hariharan, Amirtha [1 ]
Abu Arqub, Sarah [1 ]
Gandhi, Vaibhav [2 ]
Godoy, Lucas Da Cunha [3 ]
Kuo, Chia-Ling [3 ]
Uribe, Flavio [1 ]
机构
[1] Univ Connecticut Hlth, Dept Craniofacial Sci, Div Orthodont, 263 Farmington Ave, Farmington, CT 06032 USA
[2] Univ Louisville, Div Orthodont, Louisville, KY 40292 USA
[3] Univ Connecticut Hlth, Connecticut Convergence Inst Translat Regenerat E, Farmington, CT USA
关键词
Interproximal reduction; Invisalign (R); ClinCheck (R); 3D simulation; ENAMEL REDUCTION; INVISALIGN; EFFICACY;
D O I
10.1186/s40510-022-00403-w
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: To evaluate the correspondence between the interproximal reduction (IPR) performed clinically and that programmed in ClinCheck (R) and further assess which teeth showed an amount of implemented IPR (I-IPR) that corresponds with that programmed in ClinCheck (R). Materials and methods: Pre- (T0) and post-treatment (T1) ClinCheck (R) digital models for 75 subjects (30 males and 45 females), mean age (38 +/- 15) years, were included. To calculate the amount of I-IPR, Ortho Analyzer software (3Shape, Copenhagen, Denmark) was used to measure the mesiodistal widths for the maxillary and mandibular teeth from second premolar to the contralateral second premolar on the initial (T0) and final (T1) STL models. I-IPR performed by tooth was obtained by comparing the mesiodistal width of each tooth at T0 and T1.The amount of programmed IPR (P-IPR) in ClinCheck (R) was compared to that implemented clinically using the following formula: IPR difference= (P-IPR) - (I-IPR). Results: Statistically significant differences were observed between the average value of digitally programmed and implemented IPR per tooth for both the maxillary (p < .0001) and mandibular (p < .0001) teeth. The mean P-IPR for the maxillary teeth was 0.28 +/- 0.16 mm versus the mean I-IPR of 0.15 +/- 0.15 mm. In the mandibular arch, the mean P-IPR was 0.31 +/- 0.17 mm, while the I-IPR was 0.17 +/- 0.16 mm. The mean I-IPR was consistently lower than the mean P-IPR regardless of teeth and sites (p < 0.0001). The difference between the P-IPR compared to the I-IPR was larger for mandibular anterior teeth than for maxillary anterior teeth (p = 0.0302) and larger for maxillary posterior teeth than mandibular posterior teeth (p = 0.0059). Conclusion: The amount of implemented-IPR in clear aligner therapy is less than that digitally programmed for most teeth. Regardless of the regions, I-IPR was consistently lower than that programmed. Mandibular anterior teeth and maxillary posterior teeth showed greater discrepancy between P-IPR and I-IPR than the maxillary anterior and mandibular posteriors. Further prospective studies are needed to determine the factors affecting the precision of IPR and the clinical implications of a significantly reduced I-IPR on treatment outcomes.
引用
收藏
页数:10
相关论文
共 35 条
[21]  
Levrini Luca, 2015, J Clin Orthod, V49, P518
[22]   Retention and relapse in clinical practice [J].
Littlewood, S. J. ;
Kandasamy, S. ;
Huang, G. .
AUSTRALIAN DENTAL JOURNAL, 2017, 62 :51-57
[23]  
Macha Aurélio de Carvalho, 2010, Braz. oral res., V24, P58, DOI 10.1590/S1806-83242010000100010
[24]   A STRESS-ANALYSIS OF THE PERIODONTAL-LIGAMENT UNDER VARIOUS ORTHODONTIC LOADINGS [J].
MCGUINNESS, NJP ;
WILSON, AN ;
JONES, ML ;
MIDDLETON, J .
EUROPEAN JOURNAL OF ORTHODONTICS, 1991, 13 (03) :231-242
[25]  
Meeran Nazeer Ahmed, 2013, J Indian Soc Periodontol, V17, P16, DOI 10.4103/0972-124X.107468
[26]   Comparison of accuracy of mesiodistal tooth measurements made in conventional study models and digital models obtained from intraoral scan and desktop scan of study models [J].
Murugesan, Arathi ;
Sivakumar, Arvind .
JOURNAL OF ORTHODONTICS, 2020, 47 (02) :149-155
[27]   INDEX FOR ASSESSING TOOTH SHAPE DEVIATIONS AS APPLIED TO MANDIBULAR INCISORS [J].
PECK, H ;
PECK, S .
AMERICAN JOURNAL OF ORTHODONTICS, 1972, 61 (04) :384-&
[28]   Inter-proximal enamel reduction in contemporary orthodontics [J].
Pindoria, J. ;
Fleming, P. S. ;
Sharma, P. K. .
BRITISH DENTAL JOURNAL, 2016, 221 (12) :757-763
[29]   PLAQUE ACCUMULATIONS CAUSED BY INTERDENTAL STRIPPING [J].
RADLANSKI, RJ ;
JAGER, A ;
SCHWESTKA, R ;
BERTZBACH, F .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1988, 94 (05) :416-420
[30]  
Shigenobu N, 2007, ANGLE ORTHOD, V77, P303, DOI 10.2319/0003-3219(2007)077[0303:PODCIT]2.0.CO