Experimental Study on Bearing Capacity of Compression Members of Space Grid Structures Reinforced by RPC

被引:1
作者
Duan, Yutong [1 ]
Lei, Honggang [1 ]
Zhou, Yan [1 ]
Jin, Shihong [1 ]
机构
[1] Taiyuan Univ Technol, Coll Civil Engn, Taiyuan 030024, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 15期
关键词
space grid structure; RPC filling reinforcement; axial compression; initial stress; ultimate bearing capacity; STEEL; BEHAVIOR;
D O I
10.3390/app12157809
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Insufficient bearing capacity of compression bars in space grid structures can significantly reduce the collapse resistance of structures and cause immeasurable losses. Reactive powder concrete (RPC) with high strength, micro-expansion, and good ductility is used to reinforce the compression members of grid structures by infilling steel tubes. Axial compression tests on five types of high-frequency welded pipes with different section sizes and initial stresses were carried out. The results showed that compared to steel tubes alone, the bearing capacity of steel tubes reinforced by RPC could be increased by 75.77 to 218.34%. With a decrease of either the initial stress or confinement coefficient, the contribution of the material reinforcement increased. The failure mode of the specimen after RPC grouting was the same as that of the non-reinforced steel pipe, which was dominated by elastic-plastic buckling. The grouting hole after reinforcement did not fail prior to the instability of the member, which suggests that necessary measures to repair the hole should be taken. Based on the design method of axial compression bearing capacity of concrete-filled steel tubular members in six codes in China and abroad, the test results of this paper and 242 RPC-filled steel tubes were compared and analyzed. Finally, an equation of nominal bearing capacity, which estimates the ultimate bearing capacity of compressive members strengthened by filled RPC in grid structures, was proposed.
引用
收藏
页数:20
相关论文
共 49 条
[1]   A review and analysis of circular UHPC filled steel tube columns under axial loading [J].
An Le Hoang ;
Fehling, Ekkehard .
STRUCTURAL ENGINEERING AND MECHANICS, 2017, 62 (04) :417-430
[2]  
[Anonymous], 2010, Specification for Structural Steel Buildings
[3]  
[Anonymous], 2004, EN 1994-1-1
[4]  
[Anonymous], 2019, GB/T 50081
[5]  
[Anonymous], 2017, GB 50017
[6]  
[Anonymous], 2017, 23272017 ASNSZ
[7]  
[Anonymous], 1997, CONCR FILLED STEEL P
[8]  
[Anonymous], 2019, GB 51367-2019
[9]  
[Anonymous], 2011, General Administration of Quality Supervision
[10]  
[Anonymous], 2014, GB 50936-2014