Experimental study on flow characteristic of thimble heat exchanger applied to passive residual heat removal system of molten salt reactor

被引:8
作者
Ding, Tao [1 ]
Meng, Zhaoming [1 ]
Chen, Kailun [2 ]
Fan, Guangming [1 ]
Yan, Changqi [1 ]
机构
[1] Harbin Engn Univ, Fundamental Sci Nucl Safety & Simulat Technol Lab, Harbin 150001, Heilongjiang, Peoples R China
[2] Zhejiang Elect Power Design Inst Co Ltd, China Energy Engn Grp, Hangzhou 310012, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Flow characteristic; Natural circulation; Thimble tube; Molten salt reactor; Passive residual heat removal; 2-PHASE FLOW; PRESSURE-DROP; BOILING FLOW; FRICTION;
D O I
10.1016/j.applthermaleng.2019.114619
中图分类号
O414.1 [热力学];
学科分类号
摘要
In advanced fourth generation reactor Molten Salt Reactor (MSR), thimble heat exchanger projected into the drain tank is the key equipment in the Passive Residual Heat Removal System (PRHRS). In the present work, a full-scale thimble heat exchanger for 2 MW MSR have been designed and fabricated to investigate the flow performance as well as further understand the flow process for single and two phase flow in natural circulation at the operation of the PRHRS. The key parameters are measured to evaluate the flow performance mechanisms and friction pressure drop model for both single and two phase flow. Meanwhile, the traditional correlations are further compared with the experimental data of the thimble heat exchanger in the system. It is also observed that the periodic oscillations may occur in the course of operation at relative low pressure and temperature. The validated correlations provide applicable and effective references for the actual operation and safety analysis of the PRHRS in the later commercial MSR.
引用
收藏
页数:12
相关论文
共 31 条
[1]   Investigation of passive residual heat removal system for VVERs: Effects of finned type heat exchanger tubes [J].
Ayhan, Huseyin ;
Sokmen, Cemal Niyazi .
APPLIED THERMAL ENGINEERING, 2016, 108 :466-474
[2]   Experimental study on start-up and steady state characteristics of passive residual heat removal system for 2 MW molten salt reactor [J].
Chen, Kailun ;
Meng, Zhaoming ;
Yan, Changqi ;
Fan, Guangming ;
Ding, Tao .
ENERGY, 2018, 147 :826-838
[4]   PRESSURE-GRADIENTS DUE TO FRICTION DURING FLOW OF EVAPORATING 2-PHASE MIXTURES IN SMOOTH TUBES AND CHANNELS [J].
CHISHOLM, D .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1973, 16 (02) :347-358
[5]   Experimental investigation of heat transfer and pressure drop characteristics of ammonia-water in a mini-channel annulus [J].
de Bor, Dennis M. van ;
Vasilescu, Catalina ;
Ferreira, Carlos Infante .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 61 :177-186
[6]  
Friedel L., 1979, EUROPEAN 2 PHASE FLO
[7]   An experimental investigation on flow pattern map and drift-flux model for co-current upward liquid-gas two-phase flow in narrow annuli [J].
Guo, Ruixuan ;
Chen, Yuanhang ;
Waltrich, Paulo J. ;
Williams, Wesley C. .
JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2018, 51 :65-72
[8]   Modeling of void fraction covariance and relative velocity covariance for upward boiling flow in vertical pipe [J].
Hibiki, Takashi ;
Ozaki, Tetsuhiro .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 112 :620-629
[9]   Design of a passive residual heat removal system for the FUJI-233Um molten salt reactor system [J].
Ishiguro, T. ;
van Rooijen, W. F. G. ;
Shimazu, Y. ;
Mochizuki, H. .
ANNALS OF NUCLEAR ENERGY, 2014, 64 :398-407
[10]   IAEA activities on passive safety systems and overview of international development [J].
Juhn, PE ;
Kupitz, J ;
Cleveland, J ;
Cho, B ;
Lyon, RB .
NUCLEAR ENGINEERING AND DESIGN, 2000, 201 (01) :41-59